Assessment of a multiplexing high throughput immunochemical SPR biosensor in measuring multiple proteins on a single biosensor chip

被引:11
|
作者
McGrath, T. F. [1 ]
Buijs, J. [2 ]
Huet, A. C. [3 ]
Delahaut, P. [3 ]
Elliott, C. T. [1 ]
Mooney, M. H. [1 ]
机构
[1] Queens Univ, Inst Global Food Secur, Sch Biol Sci, ASSET Technol Ctr, Belfast BT9 5AG, Antrim, North Ireland
[2] GE Healthcare Biosci AB, S-75184 Uppsala, Sweden
[3] Ctr Econ Rurale, Lab Hormonol, B-6900 Marloie, Belgium
关键词
Multiplexed analysis; Surface plasmon resonance (SPR) biosensor; Multichannel array; Large molecular weight compounds; Serum protein concentrations; OPTICAL BIOSENSOR; LABEL-FREE; IMMUNOASSAY; FOOD;
D O I
10.1016/j.snb.2013.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multiplexed immunochemical detection platforms offer the potential to decrease labour demands, increase sample throughput and decrease overall time to result. A prototype four channel multiplexed high throughput surface plasmon resonance biosensor was previously developed, for the detection of food related contaminants. A study focused on determining the instruments performance characteristics was undertaken. This was followed by the development of a multiplexed assay for four high molecular weight proteins. The protein levels were simultaneously evaluated in serum samples of 10-week-old veal calves (n = 24) using multiple sample preparation methods. Each of the biosensor's four channels were shown to be independent of one another and produced multiplexed within run repeatability (n = 6) ranging from 2.0 to 6.7%CV, for the four tested proteins, whilst between run reproducibility (n = 4) ranged from 1.5 to 8.9%CV. Four calibration curves were successfully constructed before serum sample preparation was optimised for each protein. Multiplexed concentration analysis was successfully performed on four channels revealing that each proteins concentration was consistent across the twenty-four tested animals. Signal reproducibility (n > 19) on a further long term study revealed coefficient of variation ranging from 1.1% to 7.3% and showed that the multiplexed assay was stable for at least 480 cycles. These findings indicate that the performance characteristics fall within the range of previously published data for singleplex optical biosensors and that the multiplexing biosensor is fit-for-purpose for simultaneous concentration analysis in many different types of applications such as the multiplexed detection of markers of growth-promoter abuse and multiplexed detection of residues of concern in food safety. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 15 条
  • [11] Phospho-specific recognition by 14-3-3 proteins and antibodies monitored by a high throughput label-free optical biosensor
    Wu, Meng
    Coblitz, Brian
    Shikano, Sojin
    Long, Shunyou
    Spieker, Matt
    Frutos, Anthony G.
    Mukhopadhyay, Sunil
    Li, Min
    FEBS LETTERS, 2006, 580 (24) : 5681 - 5689
  • [12] Reverse Phase Protein Array is a Useful High Throughput Technique for Assessment of Multiple Proteins in Breast Cancer
    Jerjees, D. A.
    Negm, O. H.
    Alabdullah, M. L.
    Alkaabi, M.
    Mirza, S.
    Abdulajabbar, R.
    Muftah, A.
    Green, A. R.
    Tighe, P. J.
    Band, V.
    Ellis, I. O.
    Rakha, E. A.
    JOURNAL OF PATHOLOGY, 2015, 237 : S30 - S30
  • [13] A CONSTRICTION CHANNEL BASED MICROFLUIDIC FLOW CYTOMETRY ENABLING HIGH-THROUGHPUT QUANTIFICATION OF MULTIPLE TYPES OF INTRACELLULAR PROTEINS IN SINGLE CELLS
    Liu, Lixing
    Fan, Beiyuan
    Yang, Hongyu
    Chen, Deyong
    Wei, Hua
    Zhang, Guoqing
    Wang, Junbo
    Chen, Jian
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 13 - 16
  • [14] High-Throughput, Living Single-Cell, Multiple Secreted Biomarker Profiling Using Microfluidic Chip and Machine Learning for Tumor Cell Classification
    Wang, Chao
    Wang, Chunhua
    Wu, Yu
    Gao, Jianwei
    Han, Yingkuan
    Chu, Yujin
    Qiang, Le
    Qiu, Jiaoyan
    Gao, Yakun
    Wang, Yanhao
    Song, Fangteng
    Wang, Yihe
    Shao, Xiaowei
    Zhang, Yu
    Han, Lin
    ADVANCED HEALTHCARE MATERIALS, 2022, 11 (13)
  • [15] Development of microfluidic platform capable of high-throughput absolute quantification of single-cell multiple intracellular proteins from tumor cell lines and patient tumor samples
    Liu, Lixing
    Yang, Hongyu
    Men, Dong
    Wang, Meng
    Gao, Xiaolei
    Zhang, Ting
    Chen, Deyong
    Xue, Chunlai
    Wang, Yixiang
    Wang, Junbo
    Chen, Jian
    BIOSENSORS & BIOELECTRONICS, 2020, 155