Duoplasmatron beam characteristic in an ion source test stand for an accelerator mass spectrometer

被引:8
|
作者
Park, Sae-Hoon [1 ]
Lee, Sang-Hun [1 ]
Kim, Yu-Seok [1 ]
机构
[1] Dongguk Univ, Div Creat Convergence Engn, 123 Dongdae Ro, Gyeongju Si 38066, Gyeongsangbuk D, South Korea
基金
新加坡国家研究基金会;
关键词
Duoplasmatron; Accelerator mass spectrometer; Beam characteristic; ion source; SIMULATION;
D O I
10.1016/j.vacuum.2019.03.034
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A gaseous ion source has been designed at Dongguk University accelerator mass spectrometer facility, Korea. Radiocarbon dating is conducted at this facility with a mini carbon dating system and a prototype ion source has been developed for a gas injection system for high-level C-14 samples, which can decrease the precision of sample measurements for carbon dating. To improve the efficiency of carbon counting of gas samples, a gaseous ion source called a duoplasmatron has been installed in the prototype ion source test stand with low cost, easy maintenance, and direct gas discharge. It is necessary to verify the operation characteristics of the duoplasmatron of the ion source test stand with the beam characteristics to measure the beam current with various ion source parameters. The effects of the arc current, ion source magnet field, and extraction voltage on the beam current are presented in this paper.
引用
收藏
页码:246 / 249
页数:4
相关论文
共 28 条
  • [21] Broad beam gas ion source with hollow cathode discharge and four-grid accelerator system
    Tang, Deli
    Pu, Shihao
    Huang, Qi
    Tong, Honghui
    Cui, Xirong
    Chu, Paul K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 257 : 801 - 804
  • [22] INFLUENCE OF THE ION SOURCE OPERATING CONDITIONS ON THE CHARACTERISTICS OF A PRISM MASS SPECTROMETER WITH INHOMOGENEOUS MAGNETIC FIELD
    Kuzema, A. S.
    Pogrebnjak, A. D.
    Kuzema, P. A.
    JOURNAL OF NANO- AND ELECTRONIC PHYSICS, 2010, 2 (01) : 38 - 41
  • [23] Fabrication of an ion source using carbon nanoparticle field emitters for a micro time-of-flight mass spectrometer
    Yoon, H. J.
    Song, S. H.
    Cho, J. B.
    Jung, K. W.
    Lee, S.
    Koh, K. H.
    Yang, S. S.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [24] Development of Test System for Arc Power Control of EAST Neutral Beam Injector Ion Source
    Liu, Wei
    Hu, Chundong
    Liang, Lizhen
    Liu, Sheng
    Song, Shihua
    Wang, Jinxin
    FUSION SCIENCE AND TECHNOLOGY, 2019, 75 (01) : 75 - 80
  • [25] Increase of Boron Ion Beam Current Extracted from a Multi-Cusp Ion Source in an Ion Doping System with Mass Separation
    Inouchi, Yutaka
    Dohi, Shojiro
    Tanii, Masahiro
    Tatemichi, Junichi
    Konishi, Masashi
    Nukayama, Masaaki
    Nakao, Kazuhiro
    Orihira, Koichi
    Naito, Masao
    ION IMPLANTATION TECHNOLOGY 2008, 2008, 1066 : 316 - 319
  • [26] CHARACTERIZATION AND OPTIMIZATION OF A RADIOFREQUENCY GLOW-DISCHARGE ION-SOURCE FOR A HIGH-RESOLUTION MASS-SPECTROMETER
    SAPRYKIN, AI
    BECKER, JS
    DIETZE, HJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) : 897 - 901
  • [27] Time-of-flight secondary ion mass spectrometry (TOF-SIMS) using an ionic-liquid primary ion beam source
    Fujiwara, Yukio
    Saito, Naoaki
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 348 - 352
  • [28] A New Isotope Mass Spectrometer with a Thermal Ionization Cavity Ion Source and Magnetic-Electronic Double-focus Analyzer for Trace Analysis
    Zhai Li-Hua
    Wei Guan-Yi
    Deng Hu
    Li Zhi-Ming
    Zhou Guo-Qing
    Li Xue-Song
    Su Yong-Yang
    Wang Chang-Hai
    Zhang Zi-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (10) : 1543 - 1548