Comparison of clinical outcomes of coronary artery stent implantation in patients with end-stage chronic kidney disease including hemodialysis for three everolimus eluting (EES) stent designs: Bioresorbable polymer-EES, platinum chromium-EES, and cobalt chrome-EES

被引:6
作者
Sato, Takao [1 ]
Hatada, Katsuharu [2 ]
Kishi, Syohei [1 ]
Fuse, Koichi [1 ]
Fujita, Satoshi [1 ]
Ikeda, Yoshio [1 ]
Takahashi, Minoru [1 ]
Matsubara, Taku [2 ]
Okabe, Masaaki [1 ]
Aizawa, Yoshifusa [1 ]
机构
[1] Tachikawa Gen Hosp, Cardiol, 561-1 Jyojyomachi Aza Yauchi, Nagaoka, Niigata, Japan
[2] Shinrakuen Hosp, Cardiol, Niigata, Japan
关键词
end-stage chronic kidney disease; everolimus-eluting stent; in-stent restenosis; LONG-TERM SURVIVAL; MORPHOLOGICAL PREDICTORS; J-PMS; RESTENOSIS; INTERVENTION; REVASCULARIZATION; ANGIOPLASTY; HUMANS; SYSTEM; MODEL;
D O I
10.1111/joic.12469
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundsNew-generation bioresorbable polymer-everolimus eluting stents (BP-EES) are available. This study aimed to compare the clinical outcomes for BP-EES compared to more established stent designs, namely the platinum chromium-EES (PtCr-EES) and cobalt chrome-EES(CoCr-EES) in patients with the end-stage chronic kidney disease (CKD) including hemodialysis (HD). MethodsOne-hundred-forty-one consecutive stents (BP-EES [n=44], PtCr-EES [n=45], and CoCr-EES [n=52]) were implanted in 104 patients with CKD. All patients underwent a follow-up coronary angiography at 12 months after implantation. End-stage CKD was defined as an estimated glomerular filtration rate (eGFR)<30mL/min/1.73m(2), or the need for HD. The following outcome variables were compared among the three stent groups after implantation and the 12-month follow-up: target lesion revascularization (TLR), stent thrombosis (ST), and major adverse cardiac event (MACE). Minimal stent diameter (MSD) and %diameter-stenosis (%DS) were measured using quantitative coronary angiography. ResultsThe overall rate of TLR and MACE was 14.6% and 30.8%, respectively, with no incidence of ST. Immediately after implantation, the MSD (P=0.22) and %DS (P=0.42) were equivalent among the three groups. However, at the 12-month follow-up, a tendency towards higher TLR was observed for the BP-EES group (22.7%) compared with the PtCr-EES (8.8%) and CoCr-EES (9.6%) groups (P=0.07). Late loss in lumen diameter was also significantly greater for the BP-EES (0.510.64mm) group than either the PtCr-EES (0.20 +/- 0.61mm) and CoCr-EES (0.25 +/- 0.70mm) groups (P=0.03). ConclusionsBP-EES might increase the risk of in-stent restenosis in patients with end-stage of CKD or the need for HD.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 30 条
[1]   Morphological predictors of restenosis after coronary stenting in humans [J].
Farb, A ;
Weber, DK ;
Kolodgie, FD ;
Burke, AP ;
Virmani, R .
CIRCULATION, 2002, 105 (25) :2974-2980
[2]   Enhanced platelet activation following coronary stent implantation in patients on hemodialysis [J].
Fu Q. ;
Ishikawa S. ;
Yokoyama N. ;
Kozuma K. ;
Takada K. ;
Muraki A. ;
Isshiki T. .
Cardiovascular Intervention and Therapeutics, 2010, 25 (2) :72-77
[3]   Delamination of novel ultrathin bioabsorbable abluminal polymer of platinum chromium everolimus-eluting stent [J].
Fujimoto, Yoshihide ;
Kobayashi, Yoshio ;
Kato, Ken ;
Yamaguchi, Masashi .
CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2018, 33 (01) :97-98
[4]   Delamination of Abluminal Polymer of Biolimus-Eluting Stent [J].
Fujimoto, Yoshihide ;
Kobayashi, Yoshio ;
Yamaguchi, Masashi .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (03) :E5-E6
[5]   MORPHOLOGICAL PREDICTORS OF ACUTE COMPLICATIONS AFTER PERCUTANEOUS EXCIMER LASER CORONARY ANGIOPLASTY - RESULTS OF A COMPREHENSIVE ANGIOGRAPHIC ANALYSIS - IMPORTANCE OF THE ECCENTRICITY INDEX [J].
GHAZZAL, ZMB ;
HEARN, JA ;
LITVACK, F ;
GOLDENBERG, T ;
KENT, KM ;
EIGLER, N ;
DOUGLAS, JS ;
KING, SB .
CIRCULATION, 1992, 86 (03) :820-827
[6]   Independent predictors of restenosis after percutaneous coronary revascularization in haemodialysis patients [J].
Hase, H ;
Nakamura, M ;
Joki, N ;
Tsunoda, T ;
Nakamura, R ;
Saijyo, T ;
Morishita, M ;
Yamaguchi, T .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (12) :2372-2377
[7]   Usefulness of Everolimus-Eluting Coronary Stent Implantation in Patients on Maintenance Hemodialysis [J].
Ikari, Yuji ;
Kyono, Hiroyuki ;
Isshiki, Takaaki ;
Ishizuka, Shuichi ;
Nasu, Kenya ;
Sano, Koichi ;
Okada, Hisayuki ;
Sugano, Teruyasu ;
Uehara, Yoshiki .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (06) :872-876
[8]   Assessment of Sirolimus-Eluting Coronary Stent Implantation With Aspirin Plus Low Dose Ticlopidine Administration - One Year Results From CYPHER Stent Japan Post-Marketing Surveillance Registry (J-PMS) [J].
Ikari, Yuji ;
Kotani, Junichi ;
Kozuma, Ken ;
Kyo, Eishou ;
Nakamura, Masato ;
Yokoi, Hiroyoshi .
CIRCULATION JOURNAL, 2009, 73 (06) :1038-1044
[9]   Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents [J].
Kastrati, A ;
Dibra, A ;
Mehilli, J ;
Mayer, S ;
Pinieck, S ;
Pache, J ;
Dirschinger, J ;
Schöming, A .
CIRCULATION, 2006, 113 (19) :2293-2300
[10]  
Kastrati A, 2001, CIRCULATION, V103, P2816