An electropolymerized membrane biosensor for specific DNA recognition

被引:0
|
作者
Peng, TZ
Cheng, Q
Yang, FC
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310028, Zhejiang, Peoples R China
[2] Jiaxing Coll, Dept Chem Engn, Jiaxing 314001, Zhejiang, Peoples R China
[3] Rowan Univ, Dept Chem, Glassboro, NJ 08028 USA
关键词
biosensor; electrochemical polymerization; DNA sequence; hybridization;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
dA sensitive electrochemical biosensor for detecting the sequence of short DNA oligomers is represented. The biosensor is based on a platinum electrode covered a polymerized membrane of conductive monomer N-[6-(thien-3-yl)acetoxy]-pyrrolidine-2, 5-dione (TAPD). The membrane of TAPD immobilizes a probe DNA on the electrode. The hybridization of the probe with a sequence-specific DNA in sample solutions is monitored by a self-synthesized electroactive indicator, which specifically intercalates in the hybrids on the electrode surface. The current signal of the biosensor is proportional to the concentration of the target DNA in samples, and a very low detection limit of 5 x 10(-10) mol/L is found. The biosensor has been used to detect the short oligomers containing of HIV-1 and mycobacterrium nucleotide sequences.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 50 条
  • [31] An electrochemical biosensor for the sensitive detection of specific DNA based on a dual-enzyme assisted amplification
    Lin, Chunshui
    Chen, Yiying
    Cai, Zhixiong
    Luo, Feng
    Wang, Yiru
    Chen, Xi
    ELECTROCHIMICA ACTA, 2014, 147 : 785 - 790
  • [32] Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at Prussian blue-modified platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ELECTROCHIMICA ACTA, 2004, 49 (05) : 795 - 801
  • [33] Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode
    Yang, MH
    Yang, YH
    Yang, Y
    Shen, GL
    Yu, RQ
    ANALYTICAL BIOCHEMISTRY, 2004, 334 (01) : 127 - 134
  • [34] Sensitive and specific HBV genomic DNA detection using RCA-based QCM biosensor
    Yao, Chunyan
    Xiang, Yang
    Deng, Kun
    Xia, Han
    Fu, Weiling
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 382 - 387
  • [35] Electropolymerized tyrosine-based thin films: Selective cell binding via peptide recognition to novel electropolymerized biomimetic tyrosine RGDY films
    Marx, Kenneth A.
    Zhou, Tiean
    McIntosh, Donna
    Braunhut, Susan J.
    ANALYTICAL BIOCHEMISTRY, 2009, 384 (01) : 86 - 95
  • [36] Electrogenerated chemiluminescence detection of adenosine based on triplex DNA biosensor
    Ye, Sujuan
    Li, Hongxia
    Cao, Wei
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) : 2215 - 2220
  • [37] In situ electropolymerized polyaniline-polyacrylonitrile composite film for the construction of a polyphenol oxidase-based biosensor
    Xue, H
    Shen, Z
    Zheng, H
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2002, 32 (11) : 1265 - 1268
  • [38] Surface Acoustic Waves Sensor for DNA-Biosensor Development
    Fourati, Najla
    Lazerges, Mathieu
    Vedrine, Christophe
    Fougnion, Jean-Marie
    Zerrouki, Chouki
    Rousseau, Lionel
    Lepeut, Patrick
    Bonnet, Jean Jacques
    Pernelle, Christine
    SENSOR LETTERS, 2009, 7 (05) : 847 - 850
  • [39] A sequence-specific DNA sensor for Hepatitis B virus diagnostics based on the host-guest recognition
    Zheng, Jing
    Chen, Chen
    Wang, Xiaolan
    Zhang, Fan
    He, Pingang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 168 - 174
  • [40] Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus
    Zaytseva, NV
    Montagna, RA
    Lee, EM
    Baeumner, AJ