Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer (GC-TMS) for Detection of Hazardous Compounds

被引:199
作者
Contreras, Jesse A. [1 ]
Murray, Jacolin A. [1 ]
Tolley, Samuel E. [2 ]
Oliphant, Joseph L. [2 ]
Tolley, H. Dennis [1 ]
Lammert, Stephen A. [1 ]
Lee, Edgar D. [2 ]
Later, Douglas W. [2 ]
Lee, Milton L. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Tor Technol, Amer Fork, UT USA
关键词
D O I
10.1016/j.jasms.2008.06.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel gas chromatograph-mass spectrometer (GC-MS) based on a miniature toroidal ion trap mass analyzer (TMS) and a low thermal mass GC is described. The TMS system has an effective mass/charge (m/z) range of 50-442 with mass resolution at full-width half-maximum (FWHM) of 0.55 at m/z 91 and 0.80 at m/z 222. A solid-phase microextraction (SPME) fiber mounted in a simple syringe-style holder is used for sample collection and introduction into a specially designed low thermal mass GC injection port. This portable GC-TMS system weighs <13 kg (28 lb), including batteries and helium carrier gas cartridge, and is totally self-contained within dimensions of 47 X 36 X 18 cm (18.5 X 14 X 7 in.). System start-Lip takes about 3 min and sample analysis with library matching typically takes about 5 min, including time for column cool-down. Peak power consumption during sample analysis is about 80 W. Battery power and helium supply cartridges allow 50 and 100 consecutive analyses, respectively. Both can be easily replaced. An on-board library of target analytes is used to provide detection and identification of chemical compounds based on their characteristic retention times and mass spectra. The GC-TMS can detect 200 pg of methyl salicylate on-column. n-Butylbenzene and naphthalene can be detected at a concentration of 100 ppt in water from solid-phase microextraction (SPME) analysis of the headspace. The GC-TMS system has been designed to easily make measurements in a variety of complex and harsh environments. (J Am Soc Mass Spectrom 2008, 19, 1425-1434) (C) 2008 American Society for Mass Spectrometry
引用
收藏
页码:1425 / 1434
页数:10
相关论文
共 64 条
[1]  
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[2]  
Arnold NS, 2000, FIELD ANAL CHEM TECH, V4, P219, DOI 10.1002/1520-6521(2000)4:5<219::AID-FACT2>3.0.CO
[3]  
2-7
[4]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[5]  
AUTIN DE, 2007, ANAL CHEM, V79, P2927
[6]   MEMBRANE INTERFACE FOR SELECTIVE INTRODUCTION OF VOLATILE COMPOUNDS DIRECTLY INTO THE IONIZATION-CHAMBER OF A MASS-SPECTROMETER [J].
BIER, ME ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :597-601
[7]   Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps [J].
Blain, MG ;
Riter, LS ;
Cruz, D ;
Austin, DE ;
Wu, GX ;
Plass, WR ;
Cooks, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) :91-104
[8]  
DALTRONICS B, ENHANCED ENV MASS SP
[9]   Integration test of a minature ExB mass spectrometer with a gas chromatograph for development of a low-cost, portable, chemical-detection system [J].
Diaz, JA ;
Daley, P ;
Miles, R ;
Rohrs, H ;
Polla, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (04) :314-321
[10]   Portable double-focusing mass-spectrometer system for field gas monitoring [J].
Diaz, JA ;
Giese, CF ;
Gentry, WR .
FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 2001, 5 (03) :156-167