Simultaneous analysis of the non-canonical amino acids norleucine and norvaline in biopharmaceutical-related fermentation processes by a new ultra-high performance liquid chromatography approach

被引:34
作者
Biermann, Michael [1 ]
Bardl, Bettina [1 ]
Vollstaedt, Sebastian [1 ]
Linnemann, Julia [1 ]
Knuepfer, Uwe [1 ]
Seidel, Guido [2 ]
Horn, Uwe [1 ]
机构
[1] Leibniz Inst Nat Prod Res & Infect Biol HKI, D-07745 Jena, Germany
[2] Wacker Biotech GmbH, D-07745 Jena, Germany
关键词
Recombinant antibody; Norleucine; Norvaline; Ultra-high performance liquid chromatography; Biopharmaceutical fermentation; Escherichia coli; Bioprocess design; ESCHERICHIA-COLI; RECOMBINANT INTERLEUKIN-2; SERRATIA-MARCESCENS; BIOGENIC-AMINES; DERIVATIVES; SAMPLES; FLUORESCENCE; BIOSIMILARS; METHIONINE; SEPARATION;
D O I
10.1007/s00726-013-1459-3
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a precise and reliable ultra-high performance liquid chromatography (UHPLC) method for the simultaneous determination of non-canonical (norvaline and norleucine) and standard amino acids (aspartic acid, glutamic acid, serine, histidine, glycine, threonine, arginine, tyrosine, methionine, valine, phenylalanine, isoleucine, leucine) in biopharmaceutical-related fermentation processes was established. After pre-column derivatization with ortho-phthaldialdehyde and 2-mercaptoethanol, the derivatives were separated on a sub-2 mu m particle C-18 reverse-phase column. Identification and quantification of amino acids were carried out by fluorescence detection. To test method feasibility on standard HPLC instruments, the assay was properly transferred to a core-shell particle C-18 reverse-phase column. The limits of detection showed excellent sensitivity by values from 0.06 to 0.17 pmol per injection and limits of quantification between 0.19 and 0.89 pmol. In the present study, the newly established UHPLC method was applied to a recombinant antibody Escherichia coli fermentation process for the analysis of total free amino acids. We were able to specifically detect and quantify the unfavorable amino acids in such complex samples. Since we observed trace amounts of norvaline and norleucine during all fermentation phases, an obligatory process monitoring should be considered to improve quality of recombinant protein drugs in future.
引用
收藏
页码:1225 / 1231
页数:7
相关论文
共 40 条
[21]  
LeBoucher J, 1997, CLIN CHEM, V43, P1421
[22]   IDENTIFICATION OF UNUSUAL REPLACEMENT OF METHIONINE BY NORLEUCINE IN RECOMBINANT INTERLEUKIN-2 PRODUCED BY ESCHERICHIA-COLI [J].
LU, HS ;
TSAI, LB ;
KENNEY, WC ;
LAI, PH .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1988, 156 (02) :807-813
[23]   A new ultra-pressure liquid chromatography method for the determination of biogenic amines in cheese [J].
Mayer, H. K. ;
Fiechter, G. ;
Fischer, E. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (19) :3251-3257
[24]  
Molnár-Perl I, 2005, J CHROMATOGR LIBR, V70, P163
[25]   AN ANTIFUNGAL SUBSTANCE FROM A STRAIN OF B-SUBTILIS [J].
NANDI, P ;
SEN, GP .
NATURE, 1953, 172 (4384) :871-872
[26]   Optimization of separation and detection of 6-aminoquinolyl derivatives of amino acids by using reversed-phase liquid chromatography with on line UV, fluorescence and electrochemical detection [J].
Pappa-Louisi, A. ;
Nikitas, P. ;
Agrafiotou, P. ;
Papageorgiou, A. .
ANALYTICA CHIMICA ACTA, 2007, 593 (01) :92-97
[27]   Free amino acids and biogenic amines in Alicante Monastrell wines [J].
Patricia Arrieta, Marina ;
Soledad Prats-Moya, Maria .
FOOD CHEMISTRY, 2012, 135 (03) :1511-1519
[28]   Simultaneous analysis of free amino acids and biogenic amines in honey and wine samples using in loop orthophthalaldeyde derivatization procedure [J].
Pereira, V. ;
Pontes, M. ;
Camara, J. S. ;
Marques, J. C. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :435-443
[29]   Cellular mechanisms that control mistranslation [J].
Reynolds, Noah M. ;
Lazazzera, Beth A. ;
Ibba, Michael .
NATURE REVIEWS MICROBIOLOGY, 2010, 8 (12) :849-856
[30]   FLUORESCENCE REACTION FOR AMINO ACIDS [J].
ROTH, M .
ANALYTICAL CHEMISTRY, 1971, 43 (07) :880-&