Repeatability of Arterial Spin Labeling MRI in Measuring Blood Perfusion in the Human Eye

被引:16
作者
Khanal, Safal [1 ]
Turnbull, Philip R. K. [1 ]
Vaghefi, Ehsan [1 ]
Phillips, John R. [1 ,2 ]
机构
[1] Univ Auckland, Sch Optometry & Vis Sci, 85 Pk Rd, Auckland 1071, New Zealand
[2] Asia Univ, Dept Optometry, Taichung, Taiwan
关键词
arterial spin labeling; chorio-retinal perfusion; ischemic retinal diseases; magnetic resonance imaging; CHOROIDAL THICKNESS; FLOW QUANTIFICATION; RELIABILITY; CIRCULATION; INVERSION; RETINA; COIL;
D O I
10.1002/jmri.26323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Quantifying blood perfusion in ocular tissues is challenging, partly because the majority of the blood is carried by the choroid, which is difficult to visualize because it is located between the retina and sclera. Purpose/Hypothesis To evaluate the intra- and interday repeatability of MRI measures of chorio-retinal blood perfusion. Study Type Prospective, cross-sectional, observational study. Population Twenty young healthy adults (six male, age: 25 +/- 5 years) scanned twice within a single session repeated at the same time of day on 2 days. Field Strength/Sequence Arterial spin labeling (ASL) MRI at 3.0T using pseudocontinuous ASL (PCASL) labeling scheme and a 3D turbo-gradient-spin-echo (TGSE) acquisition, including axial T-2-weighted structural images using a 2D turbo-spin-echo (TSE) sequence. Assessments Region-of-interest analysis for assessment of chorio-retinal blood perfusion. Statistical Tests Intra- and interday repeatability of measures analyzed using intraclass correlation coefficients (ICC), Pearson's correlation analysis, paired t-tests, and Bland-Altman plots. Results The mean chorio-retinal perfusion was 77.86 (standard deviation [SD] = 29.80) ml/100ml/min. Perfusion measurements correlated strongly within a single session (r = 0.95, 95% confidence interval [CI] [0.880-0.980], P < 0.001) and between the two sessions based on a single run (r = 0.80 [0.582-0.913], P < 0.001), and two runs (r = 0.80 [0.479-0.918], P < 0.001). There were mean differences of 2.69 [16.85 to -22.23] ml/100ml/min for intraday measures, -7.44 [27.45 to -42.32] ml/100ml/min for single-run interday measures, and 5.73 [28.71 to -40.17] ml/100ml/min for two-run interday measures, but none were significant (all P > 0.05). Data Conclusion Quantitative ASL-MRI measurements of chorio-retinal blood perfusion showed high intra- and interday repeatability. The ASL-MRI technique provides reliable measures of chorio-retinal perfusion in vivo.
引用
收藏
页码:966 / 974
页数:9
相关论文
共 45 条
  • [31] Vaghefi E, 2017, CASE REP OPHTHALM, V8, P545, DOI 10.1159/000485316
  • [32] Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences
    Vidorreta, Marta
    Wang, Ze
    Rodriguez, Ignacio
    Pastor, Maria A.
    Detre, John A.
    Fernandez-Seara, Maria A.
    [J]. NEUROIMAGE, 2013, 66 : 662 - 671
  • [33] Retinal and Choroidal Thickness in Myopic Anisometropia
    Vincent, Stephen J.
    Collins, Michael J.
    Read, Scott A.
    Carney, Leo G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2445 - 2456
  • [34] Amplitude-modulated continuous arterial spin-labeling 3.0 T perfusion MR imaging with a single coil: Feasibility study
    Wang, JJ
    Zhang, Y
    Wolf, RL
    Roc, AC
    Alsop, DC
    Detre, JA
    [J]. RADIOLOGY, 2005, 235 (01) : 218 - 228
  • [35] Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla
    Wang, JJ
    Alsop, DC
    Li, L
    Listerud, J
    Gonzalez-At, JB
    Schnall, MD
    Detre, JA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 242 - 254
  • [36] Empirical optimization of ASL data analysis using an ASL data processing toolbox:: ASLtbx
    Wang, Ze
    Aguirre, Geoffrey K.
    Rao, Hengyi
    Wang, Jiongjiong
    Fernandez-Seara, Maria A.
    Childress, Anna R.
    Detre, John A.
    [J]. MAGNETIC RESONANCE IMAGING, 2008, 26 (02) : 261 - 269
  • [37] Arterial spin labeled MRI in prodromal Alzheimer's disease: A multi-site study
    Wang, Ze
    Das, Sandhitsu R.
    Xie, Sharon X.
    Arnold, Steven E.
    Detre, John A.
    Wolk, David A.
    [J]. NEUROIMAGE-CLINICAL, 2013, 2 : 630 - 636
  • [38] Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations
    Wang, Ze
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (10) : 1409 - 1415
  • [39] Wells W M 3rd, 1996, Med Image Anal, V1, P35
  • [40] MAGNETIC-RESONANCE-IMAGING OF PERFUSION USING SPIN INVERSION OF ARTERIAL WATER
    WILLIAMS, DS
    DETRE, JA
    LEIGH, JS
    KORETSKY, AP
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) : 212 - 216