Recording of spontaneous vagus nerve activity during Pentylenetetrazol-induced seizures in rats

被引:16
作者
Stumpp, Lars [1 ]
Smets, Hugo [2 ]
Vespa, Simone [1 ]
Cury, Joaquin [2 ]
Doguet, Pascal [3 ]
Delbeke, Jean [1 ]
Hermans, Emmanuel [1 ]
Sevcencu, Christian [4 ]
Nielsen, Thomas N. [5 ]
Nonclercq, Antoine [2 ]
El Tahry, Riem [1 ,6 ]
机构
[1] Catholic Univ Louvain, Inst Neurosci, Louvain La Neuve, Belgium
[2] Univ Libre Bruxelles, BEAMS Dept, Brussels, Belgium
[3] Synergia Med SA, Mont St Guibert, Belgium
[4] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca, Romania
[5] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[6] Clin Univ St Luc, Ctr Refractory Epilepsy, Brussels, Belgium
关键词
Vagus nerve; Seizure detection; Vagus nerve electroneurogram; PTZ; STIMULATION; INTERFERENCE;
D O I
10.1016/j.jneumeth.2020.108832
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Vagus nerve stimulation is a treatment for refractory epilepsy. The vagus nerve carries para-sympathetic information and innervates multiple organs. As seizures are commonly associated with autonomic manifestations, we believe that biomarkers for diseases affecting autonomic functions such as epilepsy can be found in vagus nerve signals. New method: We present a method to record vagus nerve electroneurogram (VENG) and detect in the VENG single unit activity in anesthetized rats during Pentylenetetrazol induced seizures using a true tripolar cuff electrode. Results: The VENG consisted of high amplitude bursts and lower amplitude bursts synchronous to respiration and heartbeat respectively. The average spikes exhibited a triphasic shape with duration below 1.5ms and root mean square amplitude varied between 5.5 +/- 0.2 mu V and 11.4 +/- 3.1 mu V depending on the type of recording. An increase of the contact distance resulted in a signal amplitude increase. Application of Lidocaine led to a total disappearance of the recorded spontaneous spiking of the nerve. Comparison with existing methods: True tripolar cuff electrodes exhibited a better performance in terms of artefact rejection, stability and reproducibility of the signal compared to commonly used hook electrodes which is of special interest in seizures where important motion and EMG artifacts are expected. Conclusion: We present a new method to record single unit activity of the vagus nerve during acute chemically induced seizures in rats and verified the neural origin of the recorded signals. This recording method might be a powerful tool to develop seizure biomarkers based on VENG.
引用
收藏
页数:9
相关论文
共 34 条
[1]   The economic impact of epilepsy: a systematic review [J].
Allers, Katharina ;
Essue, Beverley M. ;
Hackett, Maree L. ;
Muhunthan, Janani ;
Anderson, Craig S. ;
Pickles, Kristen ;
Scheibe, Franziska ;
Jan, Stephen .
BMC NEUROLOGY, 2015, 15
[2]   Measurement of the performance of nerve cuff electrodes for recording [J].
Andreasen, LNS ;
Struijk, JJ ;
Lawrence, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (04) :447-453
[3]   ABDOMINAL PATHWAYS AND CENTRAL ORIGIN OF RAT VAGAL FIBERS THAT STIMULATE GASTRIC-ACID [J].
BERTHOUD, HR ;
FOX, EA ;
POWLEY, TL .
GASTROENTEROLOGY, 1991, 100 (03) :627-637
[4]   Programmed and magnet-induced vagus nerve stimulation for refractory epilepsy [J].
Boon, P ;
Vonck, K ;
Van Walleghem, P ;
D'Havé, M ;
Goossens, L ;
Vandekerckhove, T ;
Caemaert, J ;
De Reuck, J .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2001, 18 (05) :402-407
[5]   A prospective, multicenter study of cardiac-based seizure detection to activate vagus nerve stimulation [J].
Boon, Paul ;
Vonck, Kristl ;
van Rijckevorsel, Kenou ;
El Tahry, Riem ;
Elger, Christian E. ;
Mullatti, Nandini ;
Schulze-Bonhage, Andreas ;
Wagner, Louis ;
Diehl, Beate ;
Hamer, Hajo ;
Reuber, Markus ;
Kostov, Hrisimir ;
Legros, Benjamin ;
Noachtar, Soheyl ;
Weber, Yvonne G. ;
Coenen, Volker A. ;
Rooijakkers, Herbert ;
Schijns, Olaf E. M. G. ;
Selway, Richard ;
Van Roost, Dirk ;
Eggleston, Katherine S. ;
Van Grunderbeek, Wim ;
Jayewardene, Amara K. ;
McGuire, Ryan M. .
SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2015, 32 :52-61
[6]  
Camara Richard., 2015, Nerves and Nerve Injuries, P385, DOI 10.1016/B978-0-12-410390-0.00028-7
[7]   Design of an adaptive interference reduction system for nerve-cuff electrode recording [J].
Demosthenous, A ;
Taylor, J ;
Triantis, IF ;
Rieger, R ;
Donaldson, N .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2004, 51 (04) :629-639
[8]  
Falcone Jessica D., 2018, WRAPPABLE MICROWIRE
[9]   Prevalence and incidence of epilepsy A systematic review and meta-analysis of international studies [J].
Fiest, Kirsten M. ;
Sauro, Khara M. ;
Wiebe, Samuel ;
Patten, Scott B. ;
Kwon, Churl-Su ;
Dykeman, Jonathan ;
Pringsheim, Tamara ;
Lorenzetti, Diane L. ;
Jette, Nathalie .
NEUROLOGY, 2017, 88 (03) :296-303
[10]   70 YEARS OF THE BAINBRIDGE REFLEX [J].
HAKUMAKI, MOK .
ACTA PHYSIOLOGICA SCANDINAVICA, 1987, 130 (02) :177-185