REPEATABILITY AND REPRODUCIBILITY OF RETINAL THICKNESS MEASUREMENTS WITH SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY USING DIFFERENT SCAN PARAMETERS

被引:12
作者
Giani, Andrea [1 ,2 ]
Peroglio, Antonio [1 ]
Staurenghi, Giovanni [1 ]
机构
[1] Univ Milan, Sacco Hosp, Dept Clin Sci Luigi Sacco, Eye Clin, I-20100 Milan, Italy
[2] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med, Retina Serv,Dept Ophthalmol, Boston, MA USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2012年 / 32卷 / 05期
关键词
repeatability; reproducibility; retinal thickness; SD-OCT; DIABETIC MACULAR EDEMA; INSTRUMENTS; ANALYZER;
D O I
10.1097/IAE.0b013e31822f5660
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate repeatability (test-retest) and reproducibility of retinal thickness measurements using spectral-domain optical coherence tomography with different densities of A-scans per B-scan and different frames per B-scan for real-time averaging. Methods: Twelve healthy subjects were analyzed by spectral-domain optical coherence tomography. Raster lines analysis with 19 B-scans over the examined area centered on the macula was performed. Images were acquired both in standard-density (768 A-scans/B-scan) and high-density (1,536 A-scans/B-scan) modalities. Moreover, images were acquired using 2 and 20 frames/B-scan for real-time averaging. Each analysis was repeated twice to test for repeatability. Results: Intersession repeatability was good for all studied analysis protocols, with Lin concordance correlation coefficient values ranging between 0.88 and 1.00. Reproducibility assessment showed consistent retinal thickness measurements using variable scan density, with Bland-Altman limits of agreement of -6 mu m to 6 mu m in the central area. Reproducibility assessment showed consistent retinal thickness measurements using different number of frames used in the real-time averaging process, with Bland-Altman limits of agreement of -8 mu m to 4 mu m in the central area. Conclusion: Spectral-domain optical coherence tomography is a very reliable tool for central retinal thickness assessment. Changes in the number of A-scans/B-scan and in frames used for real-time averaging do not affect repeatability and reproducibility. RETINA 32:1007-1012, 2012
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 22 条
[1]   Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging [J].
Alam, Suhail ;
Zawadzki, Robert J. ;
Choi, Stacey ;
Gerth, Christina ;
Park, Susanna S. ;
Morse, Lawrence ;
Werner, John S. .
OPHTHALMOLOGY, 2006, 113 (08) :1425-1431
[2]  
[Anonymous], 2005, R LANG ENV STAT COMP
[3]   Monitoring cystoid macular edema by optical coherence tomography in patients with retinitis pigmentosa [J].
Apushkin, MA ;
Fishman, GA ;
Janowicz, MJ .
OPHTHALMOLOGY, 2004, 111 (10) :1899-1904
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Comparison of the clinical diagnosis of diabetic macular edema with diagnosis by optical coherence tomography [J].
Browning, DJ ;
McOwen, MD ;
Bowen, RM ;
O'Marah, TL .
OPHTHALMOLOGY, 2004, 111 (04) :712-715
[6]   Comparison of the influence of cataract and pupil size on retinal nerve fibre layer thickness measurements with time-domain and spectral-domain optical coherence tomography [J].
Cheng, Clarissa S. M. ;
Natividad, Maricel G. ;
Earnest, Arul ;
Yong, Vernon ;
Lim, Boon A. ;
Wong, Hon T. ;
Yip, Leonard W. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03) :215-221
[7]  
Cheung CY, 2008, OPHTHALMOLOGY, V115, pe1
[8]   Reproducibility of Retinal Thickness Measurements on Normal and Pathologic Eyes by Different Optical Coherence Tomography Instruments [J].
Giani, Andrea ;
Cigada, Mario ;
Choudhry, Netan ;
Deiro, Antonio Peroglio ;
Oldani, Marta ;
Pellegrini, Marco ;
Invernizzi, Alessandro ;
Duca, Piergiorgio ;
Miller, Joan W. ;
Staurenghi, Giovanni .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) :815-824
[9]   ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS [J].
Giani, Andrea ;
Cigada, Mario ;
Esmaili, Daniel D. ;
Salvetti, Paola ;
Luccarelli, Saverio ;
Marziani, Ermengarda ;
Luiselli, Cristiano ;
Sabella, Pierfilippo ;
Cereda, Matteo ;
Eandi, Chiara ;
Staurenghi, Giovanni .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (04) :607-616
[10]   Topography of diabetic macular edema with optical coherence tomography [J].
Hee, MR ;
Puliafito, CA ;
Duker, JS ;
Reichel, E ;
Coker, JG ;
Wilkins, JR ;
Schuman, JS ;
Swanson, EA ;
Fujimoto, JG .
OPHTHALMOLOGY, 1998, 105 (02) :360-370