Adaptive voltage regulator design for synchronous generator

被引:27
作者
Fusco, Giuseppe [1 ]
Russo, Mario [1 ]
机构
[1] Univ Cassino, Fac Engn, I-03043 Cassino, Italy
关键词
modeling; parameter estimation; pole-assignment; sampled-data systems; synchronous generators; voltage control;
D O I
10.1109/TEC.2008.921463
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the adaptive design of an antomatic voltage regulator (AVR) control scheme for synchronous generators that is capable of providing satisfactory voltage control performance in the presence of unknown variations of the power system operating conditions. The design is articulated in four steps: voltage and current phasor estimation, estimation of the parameters of the Thevenin equivalent circuit adopted to represent the power system response using a steady-state model, determination of the sampled-data transfer function of the system, and AVR design developed according to discrete-time techniques. A suitable procedure is described to derive the sampled-data transfer function of the system starting from models of the power system, synchronous generator, and exciter. The obtained transfer function depends on the estimated parameters yielded by a recursive least-squares algorithm subject to constraints deriving from the Thevenin circuit. The AVR design is based on the pole-assignment technique while the phasors estimation is performed by two Kalman filters. Finally, the results of accurate numerical simulations conducted for a test network are reported, comparing the performance of the proposed adaptive control scheme to the one of a PID controller with fixed parameters.
引用
收藏
页码:946 / 956
页数:11
相关论文
共 32 条
[11]   Constrained least squares methods for parameter tracking of power system steady-state equivalent circuits [J].
Fusco, G ;
Losi, A ;
Russo, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) :1073-1080
[12]  
Fusco G., 2007, ADV IND CONTROL
[13]  
GHAZIZADEH MS, 1997, P I ELECT ENG GENER, V144, P271
[14]   A DIGITAL RECURSIVE MEASUREMENT SCHEME FOR ONLINE TRACKING OF POWER-SYSTEM HARMONICS [J].
GIRGIS, AA ;
CHANG, WB ;
MAKRAM, EB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (03) :1153-1160
[15]   A simplified fault currents analysis method considering transient of synchronous machine. [J].
Kai, T ;
Takeuchi, N ;
Funabashi, T ;
Sasaki, H .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1997, 12 (03) :225-231
[16]   Tuning a PID controller for a digital excitation control system [J].
Kim, K ;
Schaefer, RC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (02) :485-492
[17]  
Kundur P., 1994, POWER SYSTEM STABILI
[18]  
Li Y, 2006, IEEE CONTR SYST MAG, V26, P32
[19]   Adaptive fuzzy logic control of a turbine generator system [J].
Lown, M ;
Swidenbank, E ;
Hogg, BW .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1997, 12 (04) :394-399
[20]   ONLINE DECOUPLED IDENTIFICATION OF TRANSIENT AND SUB-TRANSIENT GENERATOR PARAMETERS [J].
MA, JT ;
HOGG, BW ;
NAN, ZY ;
YANG, YH .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (04) :1908-1914