Evaluation of SAR in a human body model due to wireless power transmission in the 10 MHz band

被引:72
作者
Laakso, Ilkka [1 ]
Tsuchida, Shogo [1 ]
Hirata, Akimasa [1 ]
Kamimura, Yoshitsugu [2 ]
机构
[1] Nagoya Inst Technol, Dept Comp Sci & Engn, Nagoya, Aichi 4668555, Japan
[2] Utsunomiya Univ, Dept Informat Sci, Utsunomiya, Tochigi, Japan
基金
芬兰科学院;
关键词
RESOLUTION;
D O I
10.1088/0031-9155/57/15/4991
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study discusses a computational method for calculating the specific absorption rate (SAR) due to a wireless power transmission system in the 10 MHz frequency band. A two-step quasi-static method comprised of the method of moments and the scalar potential finite-difference method are proposed. The applicability of the quasi-static approximation for localized exposure in this frequency band is discussed by comparing the SAR in a lossy dielectric cylinder computed with a full-wave electromagnetic analysis and the quasi-static approximation. From the computational results, the input impedance of the resonant coils was affected by the existence of the cylinder. On the other hand, the magnetic field distribution in free space and considering the cylinder and an impedance matching circuit were in good agreement; the maximum difference in the amplitude of the magnetic field was 4.8%. For a cylinder-coil distance of 10 mm, the difference between the peak 10 g averaged SAR in the cylinder computed with the full-wave electromagnetic method and our quasi-static method was 7.8%. These results suggest that the quasi-static approach is applicable for conducting the dosimetry of wireless power transmission in the 10 MHz band. With our two-step quasi-static method, the SAR in the anatomically based model was computed for different exposure scenarios. From those computations, the allowable input power satisfying the limit of a peak 10 g averaged SAR of 2.0 W kg(-1) was 830 W in the worst case exposure scenario with a coil positioned at a distance of 30 mm from the chest.
引用
收藏
页码:4991 / 5002
页数:12
相关论文
共 26 条
  • [1] Ahlbom A, 1998, HEALTH PHYS, V74, P494
  • [2] Amano T H H, 2011, P IEICE SOC C, pB
  • [3] [Anonymous], 2005, C951 IEEE
  • [4] Comparisons of computed mobile phone induced SAR in the SAM phantom to that in anatomically correct models of the human head
    Beard, Brian B.
    Kainz, Wolfgang
    Onishi, Teruo
    Iyama, Takahiro
    Watanabe, Soichi
    Fujiwara, Osamu
    Wang, Jianqing
    Bit-Babik, Giorgi
    Faraone, Antonio
    Wiart, Joe
    Christ, Andreas
    Kuster, Niels
    Lee, Ae-Kyoung
    Kroeze, Hugo
    Siegbahn, Martin
    Keshvari, Jafar
    Abrishamkar, Houman
    Simon, Winfried
    Manteuffel, Dirk
    Nikoloski, Neviana
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2006, 48 (02) : 397 - 407
  • [5] Designing passive MRI-safe implantable conducting leads with electrodes
    Bottomley, Paul A.
    Kumar, Ananda
    Edelstein, William A.
    Allen, Justin M.
    Karmarkar, Parag V.
    [J]. MEDICAL PHYSICS, 2010, 37 (07) : 3828 - 3843
  • [6] Christ A, 2011, P INT C EUR BIOELECT
  • [7] Dawson T. W., 1996, Applied Computational Electromagnetics Society Journal, V11, P63
  • [8] Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms
    Dimbylow, Peter J.
    Hirata, Akimasa
    Nagaoka, Tomoaki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) : 5883 - 5897
  • [9] Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body
    Dimbylow, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02) : 221 - 230
  • [10] FEKO Stellenbosch South Africa, 2011, EL SOFTW SYST EMSS