Converted Lumbar BMD Values Derived from Sagittal Reformations of Contrast-Enhanced MDCT Predict Incidental Osteoporotic Vertebral Fractures

被引:61
作者
Baum, Thomas [1 ]
Mueller, Dirk [1 ,2 ,3 ]
Dobritz, Martin [1 ]
Wolf, Petra [4 ]
Rummeny, Ernst J. [1 ]
Link, Thomas M. [5 ]
Bauer, Jan S. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Inst Radiol, D-81675 Munich, Germany
[2] Univ Klinikum Koln, Inst Diagnost Radiol, D-50937 Cologne, Germany
[3] Univ Klinikum Koln, Poliklin Diagnost Radiol, D-50937 Cologne, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
[5] Univ Calif San Francisco, Musculoskeletal & Quantitat Imaging Res Grp, Dept Radiol & Biomed Imaging, San Francisco, CA 94107 USA
关键词
Osteoporosis; Multidetector CT; Sagittal reformation; Bone mineral density; Incidental osteoporotic vertebral fracture; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-MINERAL DENSITY; X-RAY ABSORPTIOMETRY; MARROW FAT-CONTENT; MULTIDETECTOR CT; IN-VITRO; CANCER; SPINE; UPDATE; WOMEN;
D O I
10.1007/s00223-012-9596-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We obtained baseline and follow-up bone mineral density (BMD) values of the lumbar spine from sagittal reformations of routine abdominal contrast-enhanced multidetector computed tomography (MDCT) using a reference phantom and assessed their performance in differentiating patients with no, existing, and incidental osteoporotic fractures of the spine. A MDCT-to-QCT (quantitative computed tomography) conversion equation for lumbar BMD measurements was developed by using 15 postmenopausal women (63 +/- A 12 years), who underwent standard lumbar QCT (L1-L3) and afterward routine abdominal contrast-enhanced MDCT. Sagittal reformations were used for corresponding lumbar BMD measurements. The MDCT-to-QCT conversion equation was applied to baseline and follow-up routine abdominal contrast-enhanced MDCT scans of 149 postmenopausal women (63 +/- A 10 years). Their vertebral fracture status (no, existing, or incidental osteoporotic fracture) was assessed in the sagittal reformations. A correlation coefficient of = 0.914 ( < 0.001) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMDQCT = 0.695 x BMDMDCT - 7.9 mg/mL. Mean follow-up time of the 149 patients was 20 +/- A 12 months. Fifteen patients (10.1 %) had an existing osteoporotic vertebral fracture at baseline. Incidental osteoporotic vertebral fractures were diagnosed in 13 patients (8.7 %). Patients with existing and incidental fractures showed significantly ( < 0.05) lower converted BMD values (averaged over L1-L3) than patients without fracture at baseline and at follow-up. In this longitudinal study, BMD values of the lumbar spine derived from sagittal reformations of routine abdominal contrast-enhanced MDCT predicted incidental osteoporotic vertebral fractures.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 32 条
  • [1] Quantitative computed tomography
    Adams, Judith E.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) : 415 - 424
  • [2] ALEXEEVA L, 1994, WHO TECH REP SER, V843, P1
  • [3] [Anonymous], 2001, SOUTH MED J, V94, P569, DOI DOI 10.1097/00007611-200106000-00005
  • [4] An overview on assessing agreement with continuous measurements
    Barnhart, Huiman X.
    Haber, Michael J.
    Lin, Lawrence I.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 529 - 569
  • [5] Volumetric quantitative CT of the spine and hip derived from contrast-enhanced MDCT:: Conversion factors
    Bauer, Jan S.
    Henning, Tobias D.
    Mueeller, Dirk
    Lu, Ying
    Majumdar, Sharmila
    Link, Thomas M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1294 - 1301
  • [6] Detection of osteoporotic vertebral fractures using multidetector CT
    Bauer, JS
    Müller, D
    Ambekar, A
    Dobritz, M
    Matsuura, M
    Eckstein, F
    Rummeny, EJ
    Link, TM
    [J]. OSTEOPOROSIS INTERNATIONAL, 2006, 17 (04) : 608 - 615
  • [7] BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software
    Bauma, Thomas
    Mueller, Dirk
    Dobritz, Martin
    Rummeny, Ernst J.
    Link, Thomas M.
    Bauer, Jan S.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : E140 - E145
  • [8] A comparison of spinal quantitative computed tomography with dual energy X-ray absorptiometry in European women with vertebral and nonvertebral fractures
    Bergot, C
    Laval-Jeantet, AM
    Hutchinson, K
    Dautraix, I
    Caulin, F
    Genant, HK
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2001, 68 (02) : 74 - 82
  • [9] An Update on Dual-Energy X-Ray Absorptiometry
    Blake, Glen M.
    Fogelman, Ignac
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) : 62 - 73
  • [10] Helical Multidetector Row Quantitative Computed Tomography (QCT) Precision
    Bligh, Michael
    Bidaut, Luc
    White, R. Allen
    Murphy, William A., Jr.
    Stevens, Donna M.
    Cody, Dianna D.
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (02) : 150 - 159