Simultaneous removal of Hg0 and NO from simulated flue gas over columnar activated coke granules loaded with La2O3-CeO2 at low temperature

被引:61
作者
Gao, Lei [1 ,2 ]
Li, Caiting [1 ,2 ]
Lu, Pei [3 ]
Zhang, Jie [1 ,2 ]
Du, Xueyu [1 ,2 ]
Li, Shanhong [1 ,2 ]
Tang, Le [1 ,2 ]
Chen, Jiaqiang [1 ,2 ]
Zeng, Guangming [1 ,2 ]
机构
[1] Hunan Univ, Coll Environm Sci & Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Univ, Minist Educ, Key Lab Environm Biol & Pollut Control, Changsha 410082, Hunan, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Simultaneous removal; Elemental mercury; NO; La2O3-CeO2/AC; Adsorption; Catalytic oxidation; SELECTIVE CATALYTIC-REDUCTION; ELEMENTAL MERCURY REMOVAL; COMBINED DESULFURIZATION; MIXED OXIDES; OXIDATION; CARBON; NH3; ADSORPTION; MN; OXYGEN;
D O I
10.1016/j.fuel.2017.11.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A series of industrial desulfuration activated cokes loaded La2O3 and CeO2 (LaCe/AC) were employed for simultaneous NO and Hg-0 removal from simulated flue gas. The physicochemical characteristics of samples were characterized by BET, XRD, SEM, NH3-TPD, TGA and XPS. 25%LaCe/AC exhibited outstanding NO removal efficiency (91.3%) and superior Hg-0 removal efficiency (94.3%) at 180 degrees C. The effects of Hg-0 on SCR reaction and SCR atmosphere on Hg-0 oxidation were investigated. The results demonstrated that Hg-0 had negligible impact on NO removal efficiency while NO evidently promoted Hg-0 removal efficiency. Meanwhile, NH3 had an adverse effect on Hg-0 removal efficiency. The slightly inhibitive effect derived from the existence of H2O or SO2 was also detected. The NO removal mainly followed the Langmuir-Hinshlwood mechanism while the Hg-0 removal mechanism was attributed to the combination of physisorption and chemisorption and catalytic oxidation. Especially, the relative contributions of physisorption and chemisorption and catalytic oxidation were distinguished and calculated by designed mercury conversion and desorption tests, the results indicated chemisorption displayed the predominant role. In addition, the stability test of 27 h was carried out and eventually the sample maintained 84.5% Hg-0 removal efficiency and 89.5% NO removal efficiency, indicating its potentially large-scale industrial application at low temperatures in the foreseeable future.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 50 条
  • [21] Co3O4 nanotubes embedded in the interlayer of GO nanosheets for efficient Hg0 removal from coal flue gas
    Zhang, Xiaopeng
    Wei, Yuying
    Zhang, Lianhao
    Wang, Xinxin
    Zhang, Ning
    Bao, Junjiang
    He, Gaohong
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 320
  • [22] Efficient removal of HCHO from simulated coal combustion flue gas using CuO-CeO2 supported on cylindrical activated coke
    Sheng, Jingjing
    Li, Caiting
    Zhao, Lingkui
    Du, Xueyu
    Gao, Lei
    Zeng, Guangming
    FUEL, 2017, 197 : 397 - 406
  • [23] The simultaneous removal of SO2 and NO from flue gas over activated coke in a multi-stage fluidized bed at low temperature
    Li, Yunjia
    Zhang, Xiaoling
    Lin Huangfu
    Yu, Fengqin
    Chen, Zhaohui
    Li, Changming
    Liu, Zhouen
    Yu, Jian
    Gao, Shiqiu
    FUEL, 2020, 275 (275)
  • [24] Removal of Hg0 from simulated flue gas by MnOx modified activated carbon
    Li X.
    Li Y.
    Jin L.
    Yang H.
    Wang D.
    Hu H.
    Huagong Xuebao/CIESC Journal, 2019, 70 (08): : 3078 - 3085
  • [25] Study on the removal of elemental mercury from simulated flue gas by Fe2O3-CeO2/AC at low temperature
    Yan Wang
    Caiting Li
    Lingkui Zhao
    Yin’e Xie
    Xunan Zhang
    Guangming Zeng
    Huiyu Wu
    Jie Zhang
    Environmental Science and Pollution Research, 2016, 23 : 5099 - 5110
  • [26] Simultaneous removal of NOx and Hg0 from simulated flue gas over CuaCebZrcO3/r-Al2O3 catalysts at low temperatures: performance, characterization, and mechanism
    Huifang Yue
    Pei Lu
    Wei Su
    Yi Xing
    Rui Li
    Jiaqing Wang
    Environmental Science and Pollution Research, 2019, 26 : 13602 - 13618
  • [27] Removal of Hg0 and simultaneous removal of Hg0/SO2/NO in flue gas using two Fenton-like reagents in a spray reactor
    Liu, Yangxian
    Zhou, Jianfei
    Zhang, Yongchun
    Pan, Jianfeng
    Wang, Qian
    Zhang, Jun
    FUEL, 2015, 145 : 180 - 188
  • [28] Simultaneous removal of Hg0 and SO2 from flue gas using vacuum ultraviolet radiation combining with absorption of urea solution
    Liu, Yangxian
    Wang, Qian
    Zhang, Jun
    INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2017, 170 : 41 - 47
  • [29] Elemental mercury (Hg0) removal over spinel LiMn2O4 from coal-fired flue gas
    Xu, Haomiao
    Zhang, Hongbo
    Zhao, Songjian
    Huang, Wenjun
    Qu, Zan
    Yan, Naiqiang
    CHEMICAL ENGINEERING JOURNAL, 2016, 299 : 142 - 149
  • [30] Simultaneous removal of Hg0 and NO in simulated flue gas on transition metal oxide M′ (M′ = Fe2O3, MnO2, and WO3) doping on V2O5/ZrO2-CeO2 catalysts
    Zhao, Lingkui
    Li, Caiting
    Li, Shanhong
    Du, Xueyu
    Zhang, Junfeng
    Huang, Yan
    APPLIED SURFACE SCIENCE, 2019, 483 : 260 - 269