Comparison of linear gradient and displacement separations in ion-exchange systems

被引:19
作者
Natarajan, V [1 ]
Ghose, S [1 ]
Cramer, SM [1 ]
机构
[1] Rensselaer Polytech Inst, Dept Chem Engn, Troy, NY 12180 USA
关键词
ion exchange; optimization; displacement chromatography; steric mass action; resin materials;
D O I
10.1002/bit.10231
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The linear gradient mode of chromatography is the most widely employed mode of operation in ion-exchange chromatographic separations. However, in recent years, the displacement mode has received considerable attention because of its promise of high throughput and high resolution. To enable a comparison of these two modes of chromatography, it is essential to identify the optimum operating conditions for each. We employed an iterative algorithm to carry out the necessary optimization. The Steric Mass Action model of ion-exchange chromatography is used in concert with the solid-film linear-driving force model to describe the chromatographic behavior of the solutes in these systems. The performances of displacement and gradient modes of chromatography are compared for different types of separation problems. It turns out that for "easy" separations, both the modes are equally effective. However, for challenging separations, the displacement mode is superior to the gradient mode. Our results shed significant light on the performance of gradient and displacement modes in protein ion-exchange systems. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:365 / 375
页数:11
相关论文
共 31 条
[1]   GRADIENT ELUTION IN NON-LINEAR PREPARATIVE LIQUID-CHROMATOGRAPHY [J].
ANTIA, FD ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :1-27
[2]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[3]   Solute affinity in ion-exchange displacement chromatography [J].
Brooks, CA ;
Cramer, SM .
CHEMICAL ENGINEERING SCIENCE, 1996, 51 (15) :3847-3860
[4]   GRADIENT ELUTION IN PREPARATIVE REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
CRETIER, G ;
ROCCA, JL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 658 (02) :195-205
[5]   OPTIMIZATION OF THE EXPERIMENTAL CONDITIONS AND THE COLUMN DESIGN PARAMETERS IN DISPLACEMENT CHROMATOGRAPHY [J].
FELINGER, A ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :35-47
[6]   Comparing the optimum performance of the different modes of preparative liquid chromatography [J].
Felinger, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (01) :59-74
[7]   Optimizing experimental conditions in overloaded gradient elution chromatography [J].
Felinger, A ;
Guiochon, G .
BIOTECHNOLOGY PROGRESS, 1996, 12 (05) :638-644
[8]   INVESTIGATION OF OPERATING PARAMETERS IN HIGH-PERFORMANCE DISPLACEMENT CHROMATOGRAPHY [J].
FRENZ, J ;
VANDERSCHRIECK, P ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (01) :1-17
[9]   TRANSIENT PROFILES IN ION-EXCHANGE DISPLACEMENT CHROMATOGRAPHY [J].
GADAM, SD ;
GALLANT, SR ;
CRAMER, SM .
AICHE JOURNAL, 1995, 41 (07) :1676-1686
[10]   CHARACTERIZATION OF NONLINEAR ADSORPTION PROPERTIES OF DEXTRAN-BASED POLYELECTROLYTE DISPLACERS IN ION-EXCHANGE SYSTEMS [J].
GADAM, SD ;
JAYARAMAN, G ;
CRAMER, SM .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :37-52