For the first time, a single-piece, all-solid-state ion-selective electrode was fabricated with carbon black supporting platinum nanoparticles (PtNPs-CB) and a polymeric membrane. The PtNPs-CB, as an intermediate layer, was drop-casted directly on the solid substrate, and then an ionophore-doped solvent polymeric membrane was added in order to form a sensor. The performance of the newly developed electrodes was evaluated on the basis of potassium and nitrate ions. The stability of the electrical potential for the electrodes was examined by performing current-reversal chronopotentiometry, and the influence of the interfacial water film was assessed by the potentiometric aqueous-layer test. Fabricated potassium- and nitrate-selective electrodes displayed a Nernstian slope and several outstanding properties such as high long-term potential stability, potential repeatability, and reproducibility.
引用
收藏
页码:10255 / 10261
页数:7
相关论文
共 23 条
[1]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[2]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[3]   Conducting polymer-based solid-state ion-selective electrodes [J].
Bobacka, J .
ELECTROANALYSIS, 2006, 18 (01) :7-18
[4]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[5]   COATED WIRE ION SELECTIVE ELECTRODES [J].
CATTRALL, RW ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1905-&
[6]   Solid contact potentiometric sensors for trace level measurements [J].
Chumbimuni-Torres, KY ;
Rubinova, N ;
Radu, A ;
Kubota, LT ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1318-1322
[7]   Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers [J].
Crespo, Gaston A. ;
Macho, Santiago ;
Xavier Rius, F. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1316-1322
[8]  
Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO
[9]  
2-Q
[10]   Fullerene-based electrochemical buffer layer for ion-selective electrodes [J].
Fouskaki, Maria ;
Chaniotakis, Nikos .
ANALYST, 2008, 133 (08) :1072-1075