A device for measuring temperature and humidity in a spray dryer chamber

被引:4
作者
Kieviet, FG
VanRaaij, J
Kerkhof, PJAM
机构
[1] Lab. Separation Processes Transp. P., Department of Chemical Engineering, Eindhoven University of Technology
[2] Department of Chemical Engineering, Eindhoven University, 5600 MB Eindhoven
关键词
spray drying; computational fluid dynamics; particles; temperature measurement; humidity measurement;
D O I
10.1205/026387697523787
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The design of a device is discussed that can be used to separate small particles (similar to 10 mu m) from a gas stream. Computational fluid dynamics was used in the design process. The device proved to be very useful in measuring temperatures and humidities in a spray drying chamber.
引用
收藏
页码:329 / 333
页数:5
相关论文
共 4 条
[1]  
[Anonymous], THESIS U OXFORD
[2]   ESTIMATION OF THE DRYING RATE MOISTURE PROFILES IN AN INDUSTRIAL SPRAY DRYER BY MEANS OF EXPERIMENTAL INVESTIGATIONS AND A SIMULATION STUDY [J].
FIEG, G ;
WOZNY, G ;
BUICK, K ;
JEROMIN, L .
CHEMICAL ENGINEERING & TECHNOLOGY, 1994, 17 (04) :235-241
[3]   MEASUREMENT OF VAPOR SUPERHEAT IN POST-CRITICAL-HEAT-FLUX BOILING [J].
NIJHAWAN, S ;
CHEN, JC ;
SUNDARAM, RK ;
LONDON, EJ .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1980, 102 (03) :465-470
[4]  
Papadakis S E, 1987, THESIS U CALIFORNIA