Error Analysis and Experimental Study of a Bi-Planar Parallel Mechanism in a Pedicle Screw Robot System

被引:5
|
作者
Duan, Qingjuan [1 ]
Du, Zhijiang [2 ]
Yu, Hongjian [2 ]
Wang, Yongfeng [2 ]
Dong, Wei [2 ]
机构
[1] Xidian Univ, Sch Mechanoelect Engn, Xian 710071, Peoples R China
[2] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
关键词
robot-assistant spine surgery; bi-planar 5R mechanism; error analysis; dimension error; joint angle error; non-parallelism of the rotation axis; ACCURACY ANALYSIS; PLACEMENT;
D O I
10.3390/s16122022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to the urgent need for high precision surgical equipment for minimally invasive spinal surgery, a novel robot-assistant system was developed for the accurate placement of pedicle screws in lumbar spinal surgeries. The structure of the robot was based on a macro-micro mechanism, which includes a serial mechanism (macro part) and a bi-planar 5R parallel mechanism (micro part). The macro part was used to achieve a large workspace, while the micro part was used to obtain high stiffness and accuracy. Based on the transfer function of dimension errors, the factors affecting the accuracy of the end effectors were analyzed. Then the manufacturing errors and joint angle error on the position-stance of the end effectors were investigated. Eventually, the mechanism of the strain energy produced by the deformation of linkage via forced assembly and displacements of the output point were calculated. The amount of the transfer errors was quantitatively analyzed by the simulation. Experimental tests show that the error of the bi-planar 5R mechanism can be controlled no more than 1 mm for translation and 1 degrees for rotation, which satisfies the required absolute position accuracy of the robot.
引用
收藏
页数:14
相关论文
共 45 条
  • [31] Effect of a pedicle-screw-based motion preservation system on lumbar spine biomechanics: A probabilistic finite element study with subsequent sensitivity analysis
    Rohlmann, Antonius
    Boustani, Hadi Nabil
    Bergmann, Georg
    Zander, Thomas
    JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2963 - 2969
  • [32] An Assistive Image-Guided Surgical Robot System Using O-Arm Fluoroscopy for Pedicle Screw Insertion: Preliminary and Cadaveric Study (vol 67, pg 1757, 2010)
    Yi, Byung-Ju
    NEUROSURGERY, 2011, 68 (02)
  • [33] Economic study: a cost-effectiveness analysis of an intraoperative compared with a preoperative image-guided system in lumbar pedicle screw fixation in patients with degenerative spondylolisthesis
    Costa, Francesco
    Porazzi, Emanuele
    Restelli, Umberto
    Foglia, Emanuela
    Cardia, Andrea
    Ortolina, Alessandro
    Tomei, Massimo
    Fornari, Maurizio
    Banfi, Giuseppe
    SPINE JOURNAL, 2014, 14 (08): : 1790 - 1796
  • [34] Study on a novel thermal error compensation system for high-precision ball screw feed drive (2nd report: Experimental verification)
    Zhe-Zhu Xu
    Chang Choi
    Long-jun Liang
    Dong-yang Li
    Sung-Ki Lyu
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 2139 - 2145
  • [35] Study on a novel thermal error compensation system for high-precision ball screw feed drive (2nd report: Experimental verification)
    Xu, Zhe-Zhu
    Choi, Chang
    Liang, Long-jun
    Li, Dong-yang
    Lyu, Sung-Ki
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (10) : 2139 - 2145
  • [36] Design of a Building-Integrated Photovoltaic System with a Novel Bi-Reflector PV System (BRPVS) and Optimal Control Mechanism: An Experimental Study
    Khan, Muhammad Adil
    Zeb, Kamran
    Uddin, Waqar
    Sathishkumar, P.
    Ali, Muhammad Umair
    Hussain, S.
    Ishfaq, M.
    Himanshu
    Subramanian, Archana
    Kim, Hee-Je
    ELECTRONICS, 2018, 7 (07):
  • [37] Study on motion analysis and force/position hydraulic control of a parallel cylinder transmission system of heavy-duty quadruped robot
    Shao, Junpeng
    Jin, Chaohui
    Wang, Xigui
    Wang, Yongmei
    Jing, Jing
    Zhou, Xue
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2019, 16 (01)
  • [38] Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moir,-Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data
    Hocquelet, Arnaud
    Cornelis, Francois
    Jirot, Anna
    Castaings, Laurent
    de Seze, Mathieu
    Hauger, Olivier
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3154 - 3161
  • [39] Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moiré–Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data
    Arnaud Hocquelet
    François Cornelis
    Anna Jirot
    Laurent Castaings
    Mathieu de Sèze
    Olivier Hauger
    European Spine Journal, 2016, 25 : 3154 - 3161
  • [40] Performance Evaluation of Photovoltaic Solar System with Different Cooling Methods and a Bi-Reflector PV System (BRPVS): An Experimental Study and Comparative Analysis
    Khan, Muhammad Adil
    Ko, Byeonghun
    Alois Nyari, Esebi
    Park, S. Eugene
    Kim, Hee-Je
    ENERGIES, 2017, 10 (06)