Benchmark studies of induced radioactivity produced in LHC materials, part II: Remanent dose rates

被引:22
作者
Brugger, M
Khater, H
Mayer, S
Prinz, A
Roesler, S [1 ]
Ulrici, L
Vincke, H
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
[2] SLAC, Menlo Pk, CA 94025 USA
关键词
D O I
10.1093/rpd/nci052
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new method to estimate remanent dose rates, to be used with the Monte Carlo code FLUKA, was benchmarked against measurements from an experiment that was performed at the CERN-EU high-energy reference field facility. An extensive collection of samples of different materials were placed downstream of, and laterally to, a copper target, intercepting a positively charged mixed hadron beam with a momentum of 120 GeV c(-1). Emphasis was put on the reduction of uncertainties by taking measures such as careful monitoring of the irradiation parameters, using different instruments to measure dose rates, adopting detailed elemental analyses of the irradiated materials and making detailed simulations of the irradiation experiment. The measured and calculated dose rates are in good agreement.
引用
收藏
页码:12 / 15
页数:4
相关论文
共 9 条
[1]   Benchmark studies of induced radioactivity produced in LHC materials, part I: specific activities [J].
Brugger, M ;
Khater, H ;
Mayer, S ;
Prinz, A ;
Roesler, S ;
Ulrici, L ;
Vincke, H .
RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) :6-11
[2]  
Brugger M., 2003, P 6 INT M NUCL APPL, P391
[3]  
BRUGGER M, 2004, P 7 M SHIELD ASP ACC
[4]  
Fassò A, 2001, ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, P955
[5]  
Fassò A, 2001, ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, P159
[6]   The CERN-EU high-energy reference field (CERF) facility for dosimetry at commercial flight altitudes and in space [J].
Mitaroff, A ;
Silari, M .
RADIATION PROTECTION DOSIMETRY, 2002, 102 (01) :7-22
[7]   Overview of fluence-to-effective dose and fluence-to ambient dose equivalent conversion coefficients for high energy radiation calculated using the FLUKA code [J].
Pelliccioni, M .
RADIATION PROTECTION DOSIMETRY, 2000, 88 (04) :279-297
[8]  
Roesler S., 2003, P 6 INT M NUCL APPL, P655
[9]  
THOMAS RH, 1988, TECHNICAL REPORT SER, V283