Accuracy of segmental multi-frequency bioelectrical impedance analysis for assessing whole-body and appendicular fat mass and lean soft tissue mass in frail women aged 75 years and older

被引:118
作者
Kim, M. [1 ]
Kim, H. [1 ]
机构
[1] Tokyo Metropolitan Inst Gerontol, Res Team Promoting Independence Elderly, Tokyo 1730015, Japan
关键词
body composition; bioelectrical impedance analysis; sarcopenia; frailty; SKELETAL-MUSCLE MASS; X-RAY ABSORPTIOMETRY; SARCOPENIA; BIOIMPEDANCE; HYDRATION; PREDICTION; ADULTS; VALIDATION; ETIOLOGY; MEN;
D O I
10.1038/ejcn.2013.9
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
BACKGROUND/OBJECTIVE: We aimed to examine the accuracy of segmental multi-frequency bioelectrical impedance analysis (SMF-BIA) for the assessment of whole-body and appendicular fat mass (FM) and lean soft tissue mass (LM) in frail older women, using dual-energy X-ray absorptiometry (DXA) as a reference method. SUBJECTS/METHODS: All 129 community-dwelling Japanese frail older women with a mean age of 80.9 years (range, 75-89 years) from the Frailty Intervention Trial were recruited. The agreements between SMF-BIA and DXA for whole-body and appendicular body composition were assessed using simple linear regression and Bland-Altman analysis. RESULTS: High coefficients of determination (R-2) for whole-body FM (R-2 = 0.94, s.e. of estimate (SEE) = 1.2 kg), whole-body LM (R-2 = 0.85, SEE = 1.4 kg), and appendicular FM (R-2 = 0.82, SEE = 1.1 kg) were observed between SMF-BIA and DXA. The R-2 coefficient for appendicular LM was moderate (R-2 = 0.76, SEE = 0.8 kg). Bland-Altman plots demonstrated that there was systematic (constant) bias (that is, DXA minus SMF-BIA) with overestimation of whole-body FM (bias = -1.2 kg, 95% confidence interval (CI) = -1.5 to -0.1) and underestimation of whole-body LM (bias = 2.1 kg, 95% CI = 1.8-2.3) by SMF-BIA. Similar, the appendicular measurements also demonstrated systematic bias with overestimation of appendicular FM (bias = -0.3 kg, 95% CI = -0.5 to -0.1) and underestimation of whole-body LM (bias = 1.5 kg, 95% CI = 1.4-1.7) by SMF-BIA. In addition, the individual level accuracy demonstrated a non-proportional bias for whole-body LM (r = 0.08, P = 0.338) and appendicular FM (r = 0.07, P = 0.413). CONCLUSIONS: SMF-BIA had acceptable accuracy for the estimation of whole-body and appendicular FM and LM in frail older women, although SMF-BIA underestimated LM and overestimated FM relative to DXA. European Journal of Clinical Nutrition (2013) 67, 395-400; doi:10.1038/ejcn.2013.9; published online 6 February 2013
引用
收藏
页码:395 / 400
页数:6
相关论文
共 44 条
[1]   Utility of multifrequency bioelectrical impedance compared with dual-energy x-ray absorptiometry for assessment of total and regional body composition varies between men and women [J].
Anderson, Lindsey J. ;
Erceg, David N. ;
Schroeder, E. Todd .
NUTRITION RESEARCH, 2012, 32 (07) :479-485
[2]   Analysis of body water compartments in relation to tissue depletion in clinically stable patients with chronic obstructive pulmonary disease [J].
Baarends, EM ;
Schols, AMWJ ;
Lichtenbelt, WDVM ;
Wouters, EFM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1997, 65 (01) :88-94
[3]   Epidemiology of sarcopenia among the elderly in New Mexico [J].
Baumgartner, RN ;
Koehler, KM ;
Gallagher, D ;
Romero, L ;
Heymsfield, SB ;
Ross, RR ;
Garry, PJ ;
Lindeman, RD .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1998, 147 (08) :755-763
[4]   Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water [J].
Bedogni, G ;
Malavolti, M ;
Severi, S ;
Poli, M ;
Mussi, C ;
Fantuzzi, AL ;
Battistini, N .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2002, 56 (11) :1143-1148
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Buffa R, 2011, COLLEGIUM ANTROPOL, V35, P259
[7]   Frailty syndrome and skeletal muscle: results from the Invecchiare in Chianti study [J].
Cesari, M ;
Leeuwenburgh, C ;
Lauretani, F ;
Onder, G ;
Bandinelli, S ;
Maraldi, C ;
Guralnik, JM ;
Pahor, M ;
Ferrucci, L .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2006, 83 (05) :1142-1148
[8]   Dual-energy X-ray Absorptiometry is a valid tool for assessing skeletal muscle mass in older women [J].
Chen, Zhao ;
Wang, ZiMian ;
Lohman, Timothy ;
Heymsfield, Steven B. ;
Outwater, Eric ;
Nicholas, Jennifer S. ;
Bassford, Tamsen ;
LaCroix, Andrea ;
Sherrill, Duane ;
Punyanitya, Mark ;
Wu, Guanglin ;
Going, Scott .
JOURNAL OF NUTRITION, 2007, 137 (12) :2775-2780
[9]   Prevalence of sarcopenia estimated using a bioelectrical impedance analysis prediction equation in community-dwelling elderly people in Taiwan [J].
Chien, Meng-Yueh ;
Huang, Ta-Yi ;
Wu, Ying-Tai .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2008, 56 (09) :1710-1715
[10]  
CHUMLEA WC, 1994, NUTR REV, V52, P123, DOI 10.1111/j.1753-4887.1994.tb01404.x