Application of Magneto-Rheological Fluids for Investigating the Effect of Skin Properties on Arterial Tonometry Measurements

被引:13
|
作者
Coon, Adam [1 ]
Yang, Tae-Heon [2 ]
Kim, Young-Mm [3 ]
Kang, Heeshin [4 ]
Koo, Jeong-Hoi [1 ]
机构
[1] Miami Univ, Dept Mech & Mfg Engn, Oxford, OH 45056 USA
[2] Korea Natl Univ Transportat, Dept Elect Engn, Chungju Si, South Korea
[3] Korea Inst Oriental Med, Future Med Div, Daejeon, South Korea
[4] Korea Inst Machinery & Mat, Dept Laser & Electron Beam Aoplicat, Daejeon, South Korea
关键词
magneto-rheological fluid; skin properties; blood pressure; sub-cutaneous tissue; pulse waveforms; tonometry; BLOOD-PRESSURE; IN-VIVO; INDENTATION;
D O I
10.3389/fmats.2019.00045
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate, non-invasive measurements of blood pressure and its continuous monitoring are extremely important for personal health care. Arterial tonometry, a method that is used to provide a detailed image of a patient's cardiovascular health, shows promise for being a non-invasive alternative to current blood pressure measurement methods. However, its measurement accuracy is sensitive to patient variations such as the stiffness of the skin. Thus, this project intends to investigate the effect of skin properties (i.e., stiffness) on the accuracy of tonometric blood pressure measurements. To this end, a test platform, consisting of a pulsatile system and a tunable skin stiffness apparatus (or MR apparatus), is constructed. The cam-follower pulsatile system built based on in vivo testing of human pulses is used to generate realistic pulse waveforms. The MR apparatus is able to adjust its stiffness using Magneto-Rheological (MR) fluid whose apparent viscosity changes with applied magnetic fields. Placed at the surface of the MR apparatus, a cylinder with a frictionless plunger simulates a variable applanation force or "hold-down pressure" of tonometry by adjusting the added weights atop the cylinder. Using this test setup, a series of tests were performed by varying the input magnetic field and the weights, which effectively adjusts the skin stiffness and the hold-down pressure, respectively. The vertical displacement of the plunger caused by the internal pulse pressure was measured using a laser displacement sensor. The output displacement waveforms were analyzed with the focus on the peak amplitude difference of the waveforms, which is related to the augmentation index (a surrogate measure of arterial stiffness). The results show that there exists an "optimal" plunger weight or "hold-down pressure" that provides the most distinct output pulse waveforms. The results further show that the difference in the first two peak values decreases as the skin stiffness increases, indicating that the stiffer the skin property, the less the "hold-down pressure" effects on the accuracy of the tonometry measurements.
引用
收藏
页数:10
相关论文
共 44 条
  • [31] The Effect of Particle Concentration and Magnetic field on Tribological Behavior of Magneto-Rheological Fluid
    Song, Wan Li
    Lee, Chul Hee
    Choi, Seung Bok
    Cho, Myeong Woo
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-3, 2011, 314-316 : 58 - 61
  • [32] A Magneto-rheological fluid-based torque sensor for smart torque wrench application
    Ahmadkhanlou, Farzad
    Washington, Gregory N.
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2013, 2013, 8688
  • [33] Evaluation of sealing characteristics in MR fluid channel flow relating to magneto-rheological properties
    Nishiyama, Hideya
    Takana, Hidemasa
    Mizuki, Kotoe
    Nakajima, Tomoki
    Katagiri, Kazunari
    COMPLEX SYSTEMS-BOOK 1, 2008, 982 : 592 - 597
  • [35] AN APPLICATION OF THE MAGNETO-RHEOLOGICAL ACTUATORS TO TORSIONAL VIBRATION CONTROL OF THE ROTATING ELECTRO-MECHANICAL SYSTEMS
    Szolc, Tomasz
    Jankowski, Lukasz
    Pochanke, Andrzej
    Magdziak, Agnieszka
    8TH IFTOMM INTERNATIONAL CONFERENCE ON ROTOR DYNAMICS (IFTOMM ROTORDYNAMICS 2010), 2010, : 488 - 495
  • [36] Magneto-rheological fluids: Tele-manipulation of ferromagnetic particles with external magnetic field for flow control and zonal isolation
    Hafez, Ahmed
    Liu, Qi
    Santamarina, J. Carlos
    GEOENERGY SCIENCE AND ENGINEERING, 2023, 228
  • [38] Experimental study on the effect of finishing parameters on surface roughness in magneto-rheological abrasive flow finishing process
    Ghadikolaei, Amir Dehghan
    Vahdati, Mehrdad
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2015, 229 (09) : 1517 - 1524
  • [39] Application of Touch Sensing Technique Based on Magneto-Rheological Fluid in Constant Power Control of Coal Mining Machine
    Zhao, Can
    Liu, Dan-dan
    Tang, Chun-rui
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT II, PROCEEDINGS, 2008, 5315 : 64 - 72
  • [40] Solid waste-based set-on-demand 3D printed concrete: Active rheological control of cement-based magneto-rheological fluids
    Yue, Hongfei
    Zhang, Zhuxian
    Hua, Sudong
    Gao, Yanan
    Cui, Sheng
    Wang, Yuntao
    Zhang, Zheng
    Zhu, Huajun
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 404