Application of Magneto-Rheological Fluids for Investigating the Effect of Skin Properties on Arterial Tonometry Measurements

被引:13
|
作者
Coon, Adam [1 ]
Yang, Tae-Heon [2 ]
Kim, Young-Mm [3 ]
Kang, Heeshin [4 ]
Koo, Jeong-Hoi [1 ]
机构
[1] Miami Univ, Dept Mech & Mfg Engn, Oxford, OH 45056 USA
[2] Korea Natl Univ Transportat, Dept Elect Engn, Chungju Si, South Korea
[3] Korea Inst Oriental Med, Future Med Div, Daejeon, South Korea
[4] Korea Inst Machinery & Mat, Dept Laser & Electron Beam Aoplicat, Daejeon, South Korea
关键词
magneto-rheological fluid; skin properties; blood pressure; sub-cutaneous tissue; pulse waveforms; tonometry; BLOOD-PRESSURE; IN-VIVO; INDENTATION;
D O I
10.3389/fmats.2019.00045
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate, non-invasive measurements of blood pressure and its continuous monitoring are extremely important for personal health care. Arterial tonometry, a method that is used to provide a detailed image of a patient's cardiovascular health, shows promise for being a non-invasive alternative to current blood pressure measurement methods. However, its measurement accuracy is sensitive to patient variations such as the stiffness of the skin. Thus, this project intends to investigate the effect of skin properties (i.e., stiffness) on the accuracy of tonometric blood pressure measurements. To this end, a test platform, consisting of a pulsatile system and a tunable skin stiffness apparatus (or MR apparatus), is constructed. The cam-follower pulsatile system built based on in vivo testing of human pulses is used to generate realistic pulse waveforms. The MR apparatus is able to adjust its stiffness using Magneto-Rheological (MR) fluid whose apparent viscosity changes with applied magnetic fields. Placed at the surface of the MR apparatus, a cylinder with a frictionless plunger simulates a variable applanation force or "hold-down pressure" of tonometry by adjusting the added weights atop the cylinder. Using this test setup, a series of tests were performed by varying the input magnetic field and the weights, which effectively adjusts the skin stiffness and the hold-down pressure, respectively. The vertical displacement of the plunger caused by the internal pulse pressure was measured using a laser displacement sensor. The output displacement waveforms were analyzed with the focus on the peak amplitude difference of the waveforms, which is related to the augmentation index (a surrogate measure of arterial stiffness). The results show that there exists an "optimal" plunger weight or "hold-down pressure" that provides the most distinct output pulse waveforms. The results further show that the difference in the first two peak values decreases as the skin stiffness increases, indicating that the stiffer the skin property, the less the "hold-down pressure" effects on the accuracy of the tonometry measurements.
引用
收藏
页数:10
相关论文
共 44 条
  • [21] New magneto-rheological fluids with high stability: Experimental study and constitutive modelling
    Asiaban, R.
    Khajehsaeid, H.
    Ghobadi, E.
    Jabbari, M.
    POLYMER TESTING, 2020, 87 (87)
  • [22] Influence of HLB Parameters of Surfactants on Properties of Magneto-rheological Fluid
    Du, Chengbin
    Chen, Weiqing
    Wan, Faxue
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 843 - 847
  • [23] Fe nanoparticles produced by electric explosion of wire for new generation of magneto-rheological fluids
    Berasategi, Joanes
    Gomez, Ainara
    Bou-Ali, M. Mounir
    Gutierrez, Jon
    Barandiaran, Jose Manuel
    Beketov, Igor V.
    Safronov, Aleksander P.
    Kurlyandskaya, Galina V.
    SMART MATERIALS AND STRUCTURES, 2018, 27 (04)
  • [24] Axial squeeze strengthen effect on rotary magneto-rheological damper
    Dong, Xiaomin
    Duan, Chi
    Yu, Jianqiang
    SMART MATERIALS AND STRUCTURES, 2017, 26 (05)
  • [25] Precision Machining for Thin Wall Spherical Shell Based on Magneto-rheological Fluids Strengthening
    Kong, Jinxing
    Zheng, Yongcheng
    Wei, Qilong
    ADVANCED MANUFACTURING TECHNOLOGY AND CUTTING TOOLS, 2012, 381 : 6 - 10
  • [26] Effect of nano-silica-particle additive on magneto-rheological behavior
    Zhang, Yanan
    Jiang, Jile
    Ouyang, Chuke
    Wen, Gang
    Meng, Yonggang
    Tian, Yu
    RHEOLOGICA ACTA, 2022, 61 (11-12) : 785 - 798
  • [27] Rheological Properties of the In-house Prepared Magneto-rheological Fluid in the Pre-yield Region
    Nagiredla S.
    Joladarashi S.
    Kumar H.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (11): : 2238 - 2246
  • [28] A comparison of field-dependent rheological properties between spherical and plate-like carbonyl iron particles-based magneto-rheological fluids
    Shilan, Salihah Tan
    Mazlan, Saiful Amri
    Ido, Yasushi
    Hajalilou, Abdollah
    Jeyadevan, Balachandran
    Choi, Seung-Bok
    Yunus, Nurul Azhani
    SMART MATERIALS AND STRUCTURES, 2016, 25 (09)
  • [29] INVESTIGATION OF VARIABLE STIFFNESS EFFECTS ON RADIAL PULSE MEASUREMENTS USING MAGNETO-RHEOLOGICAL ELASTOMERS
    Weaver, Kyle
    Shumway, Dylan
    Yang, Tae-Heon
    Kim, Young-Min
    Koo, Jeong-Hoi
    PREOCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2019, 2020,
  • [30] Effective reduction of stiffness at peak frequency in hydraulic engine mounts by using magneto-rheological fluids
    Tikani, Reza
    Ziaei-Rad, Saeed
    Vahdati, Nader
    JOURNAL OF VIBROENGINEERING, 2012, 14 (02) : 866 - 879