Comparison of comprehensive two-dimensional gas chromatography in conventional and stop-flow modes

被引:22
作者
Harynuk, J [1 ]
Górecki, T [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
gas chromatography; comprehensive 2D GC; GC x GC; stop-flow GC x GC;
D O I
10.1016/j.chroma.2005.09.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new mode of operation for comprehensive two-dimensional gas chromatography (GC x GC, stop-flow GC x GC, was introduced recently. In this technique, the flow in the primary column is stopped for a brief period of time during each modulation cycle, allowing for a secondary separation time that is longer than would otherwise be permitted by the modulation period in conventional GC x GC. This allows the modulation period and the secondary separation time to become independent variables, and greatly increases the flexibility of the system. In this paper, separations obtained under similar conditions for both conventional and stop-flow GC x GC are presented, demonstrating the advantages that stop-flow GC x GC provides over conventional GC x GC for certain separations. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 167
页数:9
相关论文
共 12 条
[1]   Fast comprehensive two-dimensional gas chromatography (GC x GC) using 50-μm ID second-dimension columns [J].
Adahchour, M ;
Tasöz, A ;
Beens, J ;
Vreuls, RJJ ;
Batenburg, AM ;
Brinkman, UAT .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :753-760
[2]   Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool [J].
Dallüge, J ;
Beens, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :69-108
[3]  
FRYSINGER G, COMMUNICATION
[4]   The evolution of comprehensive two-dimensional gas chromatography (GC x GC) [J].
Górecki, T ;
Harynuk, J ;
Panic, O .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) :359-379
[5]   Flow model for coupled-column gas chromatography systems [J].
Harynuk, J ;
Górecki, T .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :135-140
[6]   Overloading of the second-dimension column in comprehensive two-dimensional gas chromatography [J].
Harynuk, J ;
Górecki, T ;
de Zeeuw, J .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :21-27
[7]   New liquid nitrogen cryogenic modulator for comprehensive two-dimensional gas chromatography [J].
Harynuk, J ;
Górecki, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :53-63
[8]   Comprehensive two-dimensional gas chromatography in stop-flow mode [J].
Harynuk, J ;
Górecki, T .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) :431-441
[9]  
HARYNUK J, 2002, 7 INT S HYPH TECHN C
[10]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE [J].
LIU, ZY ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :227-231