Calibration Method for Fully Polarimetric Microwave Radiometers Using the Correlated Noise Calibration Standard

被引:8
作者
Peng, Jinzheng [1 ]
Ruf, Christopher S. [1 ]
机构
[1] Univ Michigan, Space Phys Res Lab, Ann Arbor, MI 48109 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2008年 / 46卷 / 10期
关键词
Calibration; microwave radiometry; noise generators; polarimetry;
D O I
10.1109/TGRS.2008.2000740
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
In this paper, a new and improved L-band version of the correlated noise calibration standard (CNCS) has been developed to aid in the characterization of polarimetric microwave radiometers. The CNCS generates a series of known polarimetric test signals using a two-channel commercial arbitrary waveform generator (AWG) and a pair of frequency-upconversion modules. When it is inserted in place of the antenna used by a radiometer-under-test (RUT), it can fully characterize the polarimetric response of the receiver portion of the RUT. Both hardware and software improvements have been made over a previous version of the CNCS. The frequency upconverters now include integral warm and cold calibration-reference targets to automatically compensate for small drifts in AWG output-signal strength. The procedure used to calibrate the RUT has been generalized to correct for nonideal characteristics of the CNCS itself. Moreover, the effects on the derived polarimetric gain matrix of impedance mismatches between the RUT, and either the CNCS or the antenna have been determined. Details of the CNCS improvements are presented. The results of an experimental demonstration of its use and of a series of validation tests of its performance are also presented.
引用
收藏
页码:3087 / 3097
页数:11
相关论文
共 20 条
[1]   Analysis of correlation and total power radiometer front-ends using noise waves [J].
Corbella, I ;
Torres, F ;
Camps, A ;
Duffo, N ;
Vall-Ilossera, M ;
Rautiainen, K ;
Martín-Neira, M ;
Colliander, A .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2005, 43 (11) :2452-2459
[2]   Analysis of noise-injection networks for interferometric-radiometer calibration [J].
Corbella, I ;
Camps, A ;
Torres, F ;
Bará, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2000, 48 (04) :545-552
[3]   CALIBRATION AND APPLICATIONS OF POLARIZATION-CORRELATING RADIOMETERS [J].
GASIEWSKI, AJ ;
KUNKEE, DB .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1993, 41 (05) :767-773
[4]  
Ishimaru A., 1991, Electromagnetic wave propagation, radiation, and scattering
[5]   A calibration method for fully polarimetric microwave radiometers [J].
Lahtinen, J ;
Gasiewski, AJ ;
Klein, M ;
Corbella, I .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (03) :588-602
[6]   HUT fully polarimetric calibration standard for microwave radiometry [J].
Lahtinen, J ;
Hallikainen, MT .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (03) :603-611
[7]   Aquarius: An instrument to monitor sea surface salinity from space [J].
Le Vine, David M. ;
Lagerloef, Gary S. E. ;
Colomb, Fernando Raul ;
Yueh, Simon H. ;
Pellerano, Fernando A. .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2007, 45 (07) :2040-2050
[8]  
PENG J, 2007, P IGARSS BARC SPAIN, P2416
[9]   On-board calibration system for millimeter-wave radiometers based on reference-polarized signal injection [J].
Peverini, OA ;
Tascone, R ;
Carretti, E ;
Virone, G ;
Olivieri, A ;
Orta, R ;
Cortiglioni, S ;
Monari, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (01) :412-420
[10]   Calibration of passive microwave polarimeters that use hybrid coupler-based correlators [J].
Piepmeier, JR .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2004, 42 (02) :391-400