Spatial and temporal characteristics of physiological noise in fMRI at 3T

被引:10
作者
Liu, CSJ
Miki, A
Hulvershorn, J
Bloy, L
Gualtieri, EE
Liu, GT
Leigh, JS
Haselgrove, JC
Elliott, MA
机构
[1] Univ Penn, Sch Med, Dept Biochem & Mol Biophys, B1 Stellar Chance Labs, Philadelphia, PA 19104 USA
[2] Niigata Univ, Sch Med, Dept Ophthalmol, Niigata, Japan
[3] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[4] Hosp Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[5] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA USA
关键词
fMRI; BOLD; physiologic mechanisms;
D O I
10.1016/j.acra.2005.10.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Physiological noise in blood oxygen level-dependent functional magnetic resonance imaging (BOLD fMRI) has been shown to have characteristics similar to the BOLD signal itself, suggesting that it may have a vascular dependence. In this study, we evaluated the influence of physiological noise in fMRI as revealed by the differences in vasculature sensitivity of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI). Materials and Methods. The contribution of physiological noise to the fMRI signal during activation of the visual cortex was assessed by comparing its temporal characteristics with respect to echo time (TE), using both GE-EPI and SE-EPI. The correlation of the noise in fMRI with apparent diffusion coefficient (ADC) and the number of components required to describe its variance, as determined by principal-component analysis (PCA), were also assessed. Results. The SE-EPI data were less affected by a TE-dependence of noise, in contrast to the apparent physiological noise in GE-EPI. Voxel-wise analysis revealed that total apparent noise increased as ADC values increased, and the relationship was different for GE-EPI and SE-EPI. PCA revealed that while the number of components characterizing the noise in SE-EPI data increased in a TE-dependent manner, approaching that of white noise at long echo time, the number of components from GE-EPI data was TE-independent. Conclusions. The difference in sensitivities to physiological noise between SE-EPI and GE-EPI suggests that extravascular BOLD processes around draining veins contribute significantly to physiological noise in BOLD fMRI, and the suppression of this noise component may enhance SE-EPI BOLD sensitivity at higher fields.
引用
收藏
页码:313 / 323
页数:11
相关论文
共 29 条
  • [1] Voxel-based morphometry - The methods
    Ashburner, J
    Friston, KJ
    [J]. NEUROIMAGE, 2000, 11 (06) : 805 - 821
  • [2] SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T
    BANDETTINI, PA
    WONG, EC
    JESMANOWICZ, A
    HINKS, RS
    HYDE, JS
    [J]. NMR IN BIOMEDICINE, 1994, 7 (1-2) : 12 - 20
  • [3] Hypercapnia reversibly suppresses low-frequency fluctuations in the human motor cortex during rest using echo-planar MRI
    Biswal, B
    Hudetz, AG
    Yetkin, FZ
    Haughton, VM
    Hyde, JS
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (03) : 301 - 308
  • [4] Reduction of physiological fluctuations in fMRI using digital filters
    Biswal, B
    DeYoe, EA
    Hyde, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 107 - 113
  • [5] THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO
    BOXERMAN, JL
    BANDETTINI, PA
    KWONG, KK
    BAKER, JR
    DAVIS, TL
    ROSEN, BR
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) : 4 - 10
  • [6] MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS
    BOXERMAN, JL
    HAMBERG, LM
    ROSEN, BR
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 555 - 566
  • [7] NMR spectral quantitation by principal-component analysis .2. Determination of frequency and phase shifts
    Brown, TR
    Stoyanova, R
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 112 (01): : 32 - 43
  • [8] IMPACT: Image-based physiological artifacts estimation and correction technique for functional MRI
    Chuang, KH
    Chen, JH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 344 - 353
  • [9] ANALYSIS OF FMRI TIME-SERIES REVISITED
    FRISTON, KJ
    HOLMES, AP
    POLINE, JB
    GRASBY, PJ
    WILLIAMS, SCR
    FRACKOWIAK, RSJ
    TURNER, R
    [J]. NEUROIMAGE, 1995, 2 (01) : 45 - 53
  • [10] Glover GH, 2002, P INT SOC MAGN RESON, V10, P1395