Comparison of visual outcomes of a diffractive trifocal intraocular lens and a refractive bifocal intraocular lens in eyes with axial myopia: a prospective cohort study

被引:3
作者
Sun, Tong [1 ,2 ]
Liu, Yiyun [1 ,2 ]
Gao, Yufei [3 ]
Tang, Chuhao [1 ,2 ]
Lan, Qianqian [1 ,2 ,4 ]
Yang, Tingting [1 ,2 ]
Zhao, Xiaorui [1 ,2 ]
Qi, Hong [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Ophthalmol, Beijing, Peoples R China
[2] Peking Univ Third Hosp, Beijing Key Lab Restorat Damaged Ocular Nerve, Beijing, Peoples R China
[3] Yunnan Univ, Affiliated Hosp, Dept Ophthalmol, Kunming, Yunnan, Peoples R China
[4] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Ophthalmol, Nanning, Peoples R China
基金
中国国家自然科学基金;
关键词
Cataract; Multifocal intraocular lens; Axial length; Myopia; Visual quality; PATIENT SATISFACTION; BILATERAL IMPLANTATION; PERFORMANCE; CATARACT; DECENTRATION; PREVALENCE; BIOMETRY; QUALITY; IMPACT; LENGTH;
D O I
10.1186/s12886-022-02626-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess and compare the efficacy, safety, accuracy, predictability and visual quality of a diffractive trifocal intraocular lens (IOL) and a refractive rotationally asymmetric bifocal IOL in eyes with axial myopia. Methods: This prospective cohort study enrolled patients with implantation of the diffractive trifocal IOL or the refractive bifocal IOL. Eyes were divided into four groups according to the IOL implanted and axial length. Manifest refraction, uncorrected and corrected visual acuity at far, intermediate and near distances, prediction error of spherical equivalent (SE), contrast sensitivity and aberrations were evaluated three months after surgery. Results: In total, 80 eyes of 80 patients were included: 20 eyes in each group. Three months postoperatively, the corrected distance visual acuity of two trifocal groups were significantly better than the axial myopia bifocal group (P= 0.007 and 0.043). There was no significant difference of postoperative SE (P= 0.478), but the SE predictability of the trifocal IOL was better, whether in axial myopia groups (P = 0.015) or in control groups (P= 0.027). The contrast sensitivity was similar among four groups. The total aberration, higher order aberration and trefoil aberration of bifocal groups were significantly higher (all P < 0.001). Conclusions: The diffractive trifocal IOL and the refractive bifocal IOL both provided good efficacy, accuracy, predictability and safety for eyes with axial myopia. By contrast, the trifocal IOL had a better performance in corrected distance visual acuity and visual quality.
引用
收藏
页数:11
相关论文
共 44 条
  • [1] Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods
    Abulafia, Adi
    Barrett, Graham D.
    Rotenberg, Michael
    Kleinmann, Guy
    Levy, Adi
    Reitblat, Olga
    Koch, Douglas D.
    Wang, Li
    Assia, Ehud I.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03) : 548 - 556
  • [2] Visual outcomes and patient satisfaction after bilateral implantation of a new trifocal diffractive intraocular lens
    Almulhim, Abdulmohsen K.
    Alarfaj, Khalid M.
    Altaisan, Abdulaziz A.
    Alromaih, Arwa Z.
    Aldawod, Razan A.
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2018, 32 (04) : 310 - 317
  • [3] Visual and refractive outcomes, spectacle independence, and visual disturbances after cataract or refractive lens exchange surgery: Comparison of 2 trifocal intraocular lenses
    Asena, Bilgehan Sezgin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) : 1539 - 1546
  • [4] Accuracy of Intraocular Lens Calculations Using the IOLMaster in Eyes with Long Axial Length and a Comparison of Various Formulas
    Bang, Stacy
    Edell, Erica
    Yu, Qilu
    Pratzer, Kim
    Stark, Walter
    [J]. OPHTHALMOLOGY, 2011, 118 (03) : 503 - 506
  • [5] Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
    Chen, Shu-Yang
    Xie, Chen
    Wang, Yang
    Shen, Ye
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (07) : 1239 - 1242
  • [6] Accuracy of Modified Axial Length Adjustment for Intraocular Lens Power Calculation in Chinese Axial Myopic Eyes
    Cheng, Huanhuan
    Liu, Liangping
    Sun, Ao
    Wu, Mingxing
    [J]. CURRENT EYE RESEARCH, 2020, 45 (07) : 827 - 833
  • [7] High myopia and cataract surgery
    Chong, Elaine W.
    Mehta, Jodhbir S.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (01) : 45 - 50
  • [8] Haigis and SRKT formulae accuracy for intentional myopic overcorrection
    Dalto, Rodrigo Faeda
    Ferreira, Miriam A.
    Queiroz, Wilian
    Coelho, Roberto Pinto
    Paula, Jayter Silva
    Messias, Andre
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1459 - 1463
  • [9] Ganesh S, 2017, CLIN OPHTHALMOL, V11, P1453, DOI 10.2147/OPTH.S125921
  • [10] Short term visual outcomes of a new trifocal intraocular lens
    Garcia-Perez, Jorge L.
    Gros-Otero, Juan
    Sanchez-Ramos, Celia
    Blazquez, Vanesa
    Contreras, Ines
    [J]. BMC OPHTHALMOLOGY, 2017, 17