Evaluation of the Elekta Symmetry™ 4D IGRT System by Using a Moving Lung Phantom

被引:2
作者
Shin, Hun-Joo [1 ]
Kim, Shin-Wook [1 ]
Kay, Chul Seung [1 ]
Seo, Jae-Hyuk [2 ]
Lee, Gi-Woong [3 ]
Kang, Ki-Mun [4 ]
Jang, Hong Seok [5 ]
Kang, Young-nam [5 ]
机构
[1] Catholic Univ Korea, Coll Med, Incheon St Marys Hosp, Dept Radiat Oncol, Inchon 403720, South Korea
[2] Catholic Univ Korea, Coll Med, Bucheon St Marys Hosp, Dept Radiat Oncol, Bucheon 420717, South Korea
[3] Kyonggi Univ Korea, Sch Med, Dept Med Phys, Suwon 443760, South Korea
[4] Gyeong Sang Natl Univ Hosp, Dept Radiat Oncol, Chinju 660702, South Korea
[5] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiat Oncol, Seoul 135701, South Korea
关键词
Symmetry; 4D; IGRT; Registration; Moving phantom; BEAM COMPUTED-TOMOGRAPHY; MODULATED ARC THERAPY; RADIATION-THERAPY; CT; VERIFICATION; RADIOTHERAPY;
D O I
10.3938/jkps.67.260
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Purpose: 4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the Symmetry (TM) 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of Symmetry (TM). Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI Symmetry (TM) system. Results: The physical movement of the CIRS moving lung phantom was +/- 10.0 mm in the superior-inferior direction, +/- 1.0 mm in the lateral direction, and +/- 2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as +/- 10.2 mm in the superior-inferior direction, +/- 0.9 mm in the lateral direction, and +/- 2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the Symmetry (TM) registration as +/- 10.1 mm in the superior-inferior direction, +/- 0.9 mm in the lateral direction, and +/- 2.4 mm in the anterior-posterior direction. Conclusion: We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.
引用
收藏
页码:260 / 263
页数:4
相关论文
共 50 条
[41]   Four-dimensional tissue deformation reconstruction (4D TDR) validation using a real tissue phantom [J].
Szegedi, Martin ;
Hinkle, Jacob ;
Rassiah, Prema ;
Sarkar, Vikren ;
Wang, Brian ;
Joshi, Sarang ;
Salter, Bill .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01) :115-132
[42]   4D particle therapy PET simulation for moving targets irradiated with scanned ion beams [J].
Laube, K. ;
Menkel, S. ;
Bert, C. ;
Enghardt, W. ;
Helmbrecht, S. ;
Saito, N. ;
Fiedler, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (03) :513-533
[43]   4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapy [J].
Nakagawa, Keiichi ;
Kida, Satoshi ;
Haga, Akihiro ;
Masutani, Yoshitaka ;
Yamashita, Hideomi ;
Onoe, Tsuyoshi ;
Imae, Toshikazu ;
Tanaka, Kenichiro ;
Ohtomo, Kuni ;
Yoda, Kiyoshi .
JOURNAL OF RADIATION RESEARCH, 2012, 53 (04) :628-632
[44]   Dynamically accumulated dose and 4D accumulated dose for moving tumors [J].
Li, Heng ;
Li, Yupeng ;
Zhang, Xiaodong ;
Li, Xiaoqiang ;
Liu, Wei ;
Gillin, Michael T. ;
Zhu, X. Ronald .
MEDICAL PHYSICS, 2012, 39 (12) :7359-7367
[45]   Continuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation [J].
Han, Min Cheol ;
Seo, Jeong Min ;
Lee, Se Hyung ;
Kim, Chan Hyeong ;
Yeom, Yeon Soo ;
Thang Tat Nguyen ;
Choi, Chansoo ;
Kim, Seonghoon ;
Jeong, Jong Hwi ;
Sohn, Jason W. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (06) :2918-2924
[46]   A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT [J].
Harris, Wendy ;
Wang, Chunhao ;
Yin, Fang-Fang ;
Cai, Jing ;
Ren, Lei .
MEDICAL PHYSICS, 2018, 45 (07) :3238-3245
[47]   Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy [J].
Chung, Hyekyun ;
Jung, Jinhong ;
Jeong, Chiyoung ;
Kwak, Jungwon ;
Park, Jin-hong ;
Kim, Su Ssan ;
Yoon, Sang Min ;
Song, Si Yeol ;
Kim, Jong Hoon ;
Choi, Eun Kyung ;
Cho, Seungryong ;
Cho, Byungchul .
PLOS ONE, 2018, 13 (09)
[48]   Patient-specific finite element modeling of respiratory lung motion using 4D CT image data [J].
Werner, Rene ;
Ehrhardt, Jan ;
Schmidt, Rainer ;
Handels, Heinz .
MEDICAL PHYSICS, 2009, 36 (05) :1500-1511
[49]   Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom [J].
Yang, Bin ;
Geng, Hui ;
Ding, Ying ;
Kong, Chi Wah ;
Cheung, Chi Wai ;
Chiu, Tin Lok ;
Lam, Wai Wang ;
Cheung, Kin Yin ;
Yu, Siu Ki .
MEDICAL DOSIMETRY, 2019, 44 (01) :83-90
[50]   Estimating lung ventilation directly from 4D CT Hounsfield unit values [J].
Kipritidis, John ;
Hofman, Michael S. ;
Siva, Shankar ;
Callahan, Jason ;
Le Roux, Pierre-Yves ;
Woodruff, Henry C. ;
Counter, William B. ;
Keall, Paul J. .
MEDICAL PHYSICS, 2016, 43 (01) :33-43