Evaluation of the Elekta Symmetry™ 4D IGRT System by Using a Moving Lung Phantom

被引:2
作者
Shin, Hun-Joo [1 ]
Kim, Shin-Wook [1 ]
Kay, Chul Seung [1 ]
Seo, Jae-Hyuk [2 ]
Lee, Gi-Woong [3 ]
Kang, Ki-Mun [4 ]
Jang, Hong Seok [5 ]
Kang, Young-nam [5 ]
机构
[1] Catholic Univ Korea, Coll Med, Incheon St Marys Hosp, Dept Radiat Oncol, Inchon 403720, South Korea
[2] Catholic Univ Korea, Coll Med, Bucheon St Marys Hosp, Dept Radiat Oncol, Bucheon 420717, South Korea
[3] Kyonggi Univ Korea, Sch Med, Dept Med Phys, Suwon 443760, South Korea
[4] Gyeong Sang Natl Univ Hosp, Dept Radiat Oncol, Chinju 660702, South Korea
[5] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiat Oncol, Seoul 135701, South Korea
关键词
Symmetry; 4D; IGRT; Registration; Moving phantom; BEAM COMPUTED-TOMOGRAPHY; MODULATED ARC THERAPY; RADIATION-THERAPY; CT; VERIFICATION; RADIOTHERAPY;
D O I
10.3938/jkps.67.260
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Purpose: 4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the Symmetry (TM) 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of Symmetry (TM). Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI Symmetry (TM) system. Results: The physical movement of the CIRS moving lung phantom was +/- 10.0 mm in the superior-inferior direction, +/- 1.0 mm in the lateral direction, and +/- 2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as +/- 10.2 mm in the superior-inferior direction, +/- 0.9 mm in the lateral direction, and +/- 2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the Symmetry (TM) registration as +/- 10.1 mm in the superior-inferior direction, +/- 0.9 mm in the lateral direction, and +/- 2.4 mm in the anterior-posterior direction. Conclusion: We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.
引用
收藏
页码:260 / 263
页数:4
相关论文
共 50 条
  • [21] Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration
    Ehrhardt, Jan
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 251 - 265
  • [22] 4D patient dose reconstruction using online measured EPID cine images for lung SBRT treatment validation
    Lin, Mu-Han
    Li, Jinsheng
    Wang, Lu
    Koren, Sion
    Fan, Jiajing
    Forkal, Eugene
    Ma, C. -M.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5949 - 5958
  • [23] Comparison of two respiration monitoring systems for 4D imaging with a Siemens CT using a new dynamic breathing phantom
    Vasquez, A. C.
    Runz, A.
    Echner, G.
    Sroka-Perez, G.
    Karger, C. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) : N131 - N143
  • [24] First 4D In-beam PET Measurement for Beam Tracking of a Moving Phantom with a Scanned Carbon Ion Beam
    Parodi, K.
    Saito, N.
    Richter, C.
    Chaudhri, N.
    Enghardt, W.
    Rietzel, E.
    Bert, C.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3794 - +
  • [25] Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans
    Killoran, Joseph H.
    Gerbaudo, Victor H.
    Mamede, Marcelo
    Ionascu, Dan
    Park, Sang-June
    Berbeco, Ross
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 261 - 274
  • [26] Development of a Multi-Modality 4D Biomechanical Phantom for Evaluation of Simultaneous Registration/Segmentation Algorithms
    Markel, D.
    Larkin, J.
    Leger, P.
    Levesque, I. R.
    El Naqa, I.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 373 - 376
  • [27] Comparison of intelligent 4D CT sequence scanning and conventional spiral 4D CT: A first comprehensive phantom study
    Werner R.
    Szkitsak J.
    Sentker T.
    Madesta F.
    Schwarz A.
    Fernolendt S.
    Vornehm M.
    Gauer T.
    Bert C.
    Hofmann C.
    [J]. Physics in Medicine and Biology, 2021, 66 (01)
  • [28] 4D Lung Reconstruction with Phase Optimization
    Lyksborg, Mark
    Paulsen, Rasmus
    Brink, Carsten
    Larsen, Rasmus
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2227 - 2230
  • [29] 4D CBCT reconstruction with TV regularization on a dynamic software phantom
    Heylen, Rob
    Schramm, Georg
    Suetens, Paul
    Nuyts, Johan
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [30] Prospective evaluation of a dedicated spine radiosurgery program using the Elekta Synergy S system
    Gerszten, Peter C.
    Novotny, Josef, Jr.
    Quader, Mubina
    Dewald, Valerie C.
    Flickinger, John C.
    [J]. JOURNAL OF NEUROSURGERY, 2010, 113 : 236 - 241