SPECT image segmentation for estimation of tumour volume and activity concentration in 177Lu-DOTATATE radionuclide therapy

被引:30
作者
Gustafsson, Johan [1 ]
Sundlov, Anna [2 ,3 ]
Gleisner, Katarina Sjogreen [1 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Clin Sci Lund, Lund, Sweden
[2] Lund Univ, Dept Pathol & Oncol, Clin Sci Lund, Lund, Sweden
[3] Skane Univ Hosp, Dept Oncol, Lund, Sweden
基金
瑞典研究理事会;
关键词
SPECT; Segmentation; Radionuclide therapy; Activity quantification; NEUROENDOCRINE TUMORS; RECOVERY COEFFICIENTS; FOURIER SURFACES; DOSIMETRY; ACCURACY; METHODOLOGY; VARIABILITY; ALGORITHM;
D O I
10.1186/s13550-017-0262-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Dosimetry in radionuclide therapy has the potential to allow for a treatment tailored to the individual patient. One therapeutic radiopharmaceutical where patient-specific dosimetry is feasible is Lu-177-DOTATATE, used for the treatment of neuroendocrine tumours. The emission of gamma photons by Lu-177 allows for imaging with SPECT (single photon emission computed tomography). One important step for dosimetry using this imaging technique is the SPECT image segmentation, which needs to be robust and accurate for the estimated quantities to be reliable. This work investigates different methods for automatic tumour delineation in Lu-177-DOTATATE SPECT images. Three segmentation methods are considered: a fixed 42% threshold (FT), the Otsu method (OM) and a method based on Fourier surfaces (FS). Effects of including resolution compensation in the iterative SPECT image reconstruction are also studied. Evaluation is performed based on Monte Carlo-simulated SPECT images from 24 h and 336 h post injection (p.i.), for determination of the volume, activity concentration and dice similarity coefficient. In addition, patient data are used to investigate the correspondence of tumour volumes when delineated in SPECT or morphological CT or MR images. Patient data are also used to examine the sensitivity to the operator-dependent initialization. Results: For simulated images from 24 h p.i. reconstructed without resolution compensation, a volume and activity-concentration root-mean-square error below 15% is typically obtained for tumours above approximately 10 cm(3) when using OM or FS, while FT performs considerably worse. When including resolution compensation, the tumour volume becomes underestimated and the activity concentration overestimated. The FS method appears to be robust to noise, as seen for the 336 h images. The differences between the tumour volumes estimated from the SPECT images and the volumes estimated from morphological images are generally larger than the discrepancies seen for the simulated data sets. Conclusions: Segmentation results are encouraging for future dosimetry of tumours with volumes above approximately 10 cm(3). Using resolution compensation in the reconstruction may have a negative effect on volume estimation.
引用
收藏
页数:17
相关论文
共 47 条
[21]   The accuracy and reproducibility of SPECT target volumes and activities estimated using an iterative adaptive thresholding technique [J].
Grimes, Joshua ;
Celler, Anna ;
Shcherbinin, Sergey ;
Piwowarska-Bilska, Hanna ;
Birkenfeld, Bozena .
NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (12) :1254-1266
[22]  
Gustafsson J, 2012, EUR J NUCL MED MO S2, V39, P311
[23]   A Fuzzy Locally Adaptive Bayesian Segmentation Approach for Volume Determination in PET [J].
Hatt, Mathieu ;
le Rest, Catherine Cheze ;
Turzo, Alexandre ;
Roux, Christian ;
Visvikis, Dimitris .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (06) :881-893
[24]   Dose Response of Pancreatic Neuroendocrine Tumors Treated with Peptide Receptor Radionuclide Therapy Using 177Lu-DOTATATE [J].
Ilan, Ezgi ;
Sandstrom, Mattias ;
Wassberg, Cecilia ;
Sundin, Anders ;
Garske-Roman, Ulrike ;
Eriksson, Barbro ;
Granberg, Dan ;
Lubberink, Mark .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (02) :177-182
[25]   Iodine-124 PET dosimetry in differentiated thyroid cancer:: recovery coefficient in 2D and 3D modes for PET(/CT) systems [J].
Jentzen, Walter ;
Weise, Reiner ;
Kupferschlaeger, Juergen ;
Freudenberg, Lutz ;
Brandau, Wolfgang ;
Bares, Ronald ;
Burchert, Wolfgang ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (03) :611-623
[26]  
Jentzen W, 2007, J NUCL MED, V48, P108
[27]   Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging [J].
Jentzen, Walter .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (08) :2365-2398
[28]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[29]   SPECT VOLUME QUANTITATION - INFLUENCE OF SPATIAL-RESOLUTION, SOURCE SIZE AND SHAPE, AND VOXEL SIZE [J].
KING, MA ;
LONG, DT ;
BRILL, AB .
MEDICAL PHYSICS, 1991, 18 (05) :1016-1024
[30]   I-131 SPECT activity recovery coefficients with implicit or triple-energy-window scatter correction [J].
Koral, KF ;
Dewaraja, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :688-692