In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging

被引:197
作者
Morbiducci, Umberto
Ponzini, Raffaele [2 ]
Rizzo, Giovanna [3 ]
Cadioli, Marcello [4 ]
Esposito, Antonio [5 ]
De Cobelli, Francesco [5 ]
Del Maschio, Alessandro [5 ]
Montevecchi, Franco Maria [1 ]
Redaelli, Alberto [6 ]
机构
[1] Politecn Torino, Dept Mech, I-10129 Turin, Italy
[2] Interunivers Consortium, CILEA, Milan, Italy
[3] CNR, Ist Bioimmagini & Fisiol Mol, Milan, Italy
[4] Philips Med Syst, Milan, Italy
[5] Sci Inst HS Raffaele, Dept Radiol, Milan, Italy
[6] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
关键词
Aorta; Helical flow; Biofluid mechanics; Phase contrast MRI; Hemodynamics; Helicity; Blood flow; PHYSIOLOGICAL PULSATILE FLOW; SPIRAL LAMINAR-FLOW; WALL SHEAR-STRESS; HEALTHY-VOLUNTEERS; T; PATTERNS; VISUALIZATION; MECHANICS; DYNAMICS; ARTERIES;
D O I
10.1007/s10439-008-9609-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mechanics of blood flow in arteries plays a key role in the health of individuals. In this framework, the role played by the presence of helical flow in the human aorta is still not clear in its relation to physiology and pathology. We report here a method for quantifying helical flow in vivo employing time-resolved cine phase contrast magnetic resonance imaging to obtain the complete spatio-temporal description of the three-dimensional pulsatile blood flow patterns in aorta. The method is applied to data of one healthy volunteer. Particle traces were calculated from velocity data: to them we applied a Lagrangian-based method for helical flow quantification, the Helical Flow Index, which has been developed and evaluated in silico in order to reveal global organization of blood flow. Our results: (i) put in evidence that the systolic hemodynamics in aorta is characterized by an evolving helical flow (we quantified a 24% difference in terms of the content of helicity in the streaming blood, between mid and early systole); (ii) indicate that in the first part of the systole helicity is ascrivable mainly to the asymmetry of blood flow in the left ventricle, joined with the laterality of the aorta. In conclusion, this study shows that the quantification of helical blood flow in vivo is feasible, and it might allow detection of anomalies in the expected physiological development of helical flow in aorta and accordingly, could be used in a diagnostic/prognostic index for clinical practice.
引用
收藏
页码:516 / 531
页数:16
相关论文
共 54 条
[1]  
Baciewicz F.A., 1991, Cardiac Chronicle, V5, P1
[2]   Helical turbulence: turbulent viscosity and instability of the second moments [J].
Belian, A ;
Chkhetiani, O ;
Golbraikh, E ;
Moiseev, S .
PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 1998, 258 (1-2) :55-68
[3]   FLUID MECHANICS OF AORTIC VALVE [J].
BELLHOUS.BJ ;
TALBOT, L .
JOURNAL OF FLUID MECHANICS, 1969, 35 :721-&
[4]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[5]   Analysis of flow patterns using MRI [J].
Buonocore, MH ;
Bogren, HG .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (02) :99-103
[6]   Non-planar curvature and branching of arteries and non-planar-type flow [J].
Caro, CG ;
Doorly, DJ ;
Tarnawski, M ;
Scott, KT ;
Long, Q ;
Dumoulin, CL .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1996, 452 (1944) :185-197
[7]   FLOW DYNAMICS IN THE HUMAN AORTA [J].
CHANDRAN, KB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :611-616
[8]   EXPERIMENTAL-STUDY OF PHYSIOLOGICAL PULSATILE FLOW IN A CURVED TUBE [J].
CHANDRAN, KB ;
YEARWOOD, TL .
JOURNAL OF FLUID MECHANICS, 1981, 111 (OCT) :59-85
[9]   EXPERIMENTAL-STUDY OF PULSATILE FLOW IN A CURVED TUBE [J].
CHANDRAN, KB ;
YEARWOOD, TL ;
WIETING, DW .
JOURNAL OF BIOMECHANICS, 1979, 12 (10) :793-805
[10]   OSCILLATORY FLOW IN THIN-WALLED CURVED ELASTIC TUBES [J].
CHANDRAN, KB ;
SWANSON, WM ;
GHISTA, DN ;
VAYO, HW .
ANNALS OF BIOMEDICAL ENGINEERING, 1974, 2 (04) :392-412