K-space trajectories in 3D-GRASE sequence for high resolution structural imaging

被引:7
作者
Cristobal-Huerta, Alexandra [1 ]
Poot, Dirk H. J. [1 ,2 ]
Vogel, Mika W. [3 ]
Krestin, Gabriel P. [1 ]
Hernandez-Tamames, Juan A. [1 ]
机构
[1] Erasmus MC, Dept Radiol & Nucl Med, S Gravendijkwal 230, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Med Informat, Rotterdam, Netherlands
[3] GE Healthcare, Hoevelaken, Netherlands
关键词
Gradient and spin echo (GRASE); Fast spin echo (FSE); Echo planar imaging (EPI); Parallel imaging; SAR; Trajectory; FAST SPIN-ECHO; MR-IMAGES; 3D GRASE; PHASE; RECONSTRUCTION; RELAXATION; CONTRAST; STRATEGY; TRAINS; BRAIN;
D O I
10.1016/j.mri.2017.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and evaluate new k-space trajectories for 3D-GRASE to improve scan time over 3D-FSE/TSE for high resolution structural imaging. Methods: Five different Cartesian k-space trajectories were developed and evaluated. They combine ideas of existing k-space trajectories for 3D-GRASE and 3D-FSE/TSE. T2 and T2* are linearly or radially modulated in k space to achieve the desired contrast while including the autocalibration region needed for the parallel imaging reconstruction technique. Phase modulation among echoes was corrected in reconstruction to remove remaining artefacts. Simulation and in-vivo experiments on a 3T scanner were conducted to evaluate the performance of the different k-space trajectories. Results: Two of the proposed k-space trajectories for high resolution structural imaging with 3D-GRASE obtained images comparable to 3D-FSE with lower specific absorption rate (PD/T2: 41%/75%) and shorter acquisition time (PD/T2: 27%/20%). Conclusions: 3D-GRASE image quality strongly depends on the k-space trajectory. With an optimal trajectory, 3D-GRASE may be preferable over 3D-FSE/TSE for structural high-resolution MRI.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 34 条
[1]   Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy [J].
Bernstein, MA ;
Fain, SB ;
Riederer, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :270-280
[2]  
Brau AnjaC.S., 2006, Proceedings of the 14th Annual Meeting of ISMRM, P2462
[3]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[4]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[5]  
Cristobal-Huerta A, 2017, P 25 ANN M ISMRM HON, P1500
[6]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[7]  
Feinberg D., 2009, P 17 ANN M ISMRM HON, P623
[8]   INCREASED FLEXIBILITY IN GRASE IMAGING BY K-SPACE-BANDED PHASE-ENCODING [J].
FEINBERG, DA ;
JOHNSON, G ;
KIEFER, B .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :149-155
[9]  
Glover G., 1986, US Patent, Patent No. [4,591,789., 4591789, 4,591,789]
[10]   Radial GRASE: Implementation and applications [J].
Gmitro, AF ;
Kono, M ;
Theilmann, RJ ;
Altbach, MI ;
Li, ZQ ;
Trouard, TP .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) :1363-1371