Comparison of Time-Domain Short-Term Heart Interval Variability Analysis Using a Wrist-Worn Heart Rate Monitor and the Conventional Electrocardiogram

被引:87
|
作者
Grossi Porto, Luiz Guilherme [1 ]
Junqueira, Luiz F., Jr.
机构
[1] Univ Brasilia, Fac Med, Cardiovasc Lab, Clin Med Area, BR-70910900 Brasilia, DF, Brazil
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 01期
关键词
wrist-worn heart rate monitor; Polar monitor; exercise practice; heart rate variability; cardiac autonomic function; SYMPATHOVAGAL BALANCE; PHYSIOLOGICAL-BASIS; NEURAL MECHANISMS; EXERCISE; ACCURACY; VALIDITY; DISEASE; MODULATION; AGREEMENT; RISK;
D O I
10.1111/j.1540-8159.2009.02175.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Wrist-worn heart rate monitors have not been extensively validated for heart rate variability analysis. The purpose of this study was to compare time-domain variability of heart interval series (R-Ri) recorded by the Polar S810 monitor (Polar Electro Oy, Kempele, Finland) and the conventional electrocardiogram (ECG). Methods: Agreement was verified between variability indices of 5-minute R-Ri simultaneously recorded by both devices and processed by unique software, from 33 subjects aged 18 to 42 years, normal or with different clinical conditions, in rest supine and active standing. ECG minus Polar differences were quantified by the Bland-Altman analysis, and tested by the one-sample t-test or Wilcoxon test. Results: In the supine position, the Polar overestimates (P < 0.0001) the absolute and percentage mean or median of the number (-2.00; -0.49%) and mean of R-Ri (-1.85 ms; -0.20%) and pNN50 (-2.20%; -8.68%), and underestimates the standard deviation (SDNN) (0.32 ms; 0.59%) (P = 0.08; P = 0.02) and root mean square successive difference (RMSSD) (0.90 ms; 1.56%) (P = 0.0008; P < 0.0001). The coefficient of variation (CV) showed null difference. On standing, differences were overestimated for the number (-2.61 intervals; -0.64%) and mean of R-Ri (-0.70 ms; -0.09%), and underestimated for rMSSD (1.70 ms; 10.84%) (P < 0.0001 to < 0.02). The SDNN, CV, and pNN50 indices did not show differences (P = 0.12 to 0.73). Conclusions: The Polar S810 monitor was feasible and reliable for recording short-term R-R interval series, showing excellent agreement with the ECG in providing the time-domain indexes of heart interval variability with differences functionally not relevant. The CV showed the higher agreement in both postures, and the SDNN and pNN50 in the standing posture. (PACE 2009; 32:43-51).
引用
收藏
页码:43 / 51
页数:9
相关论文
共 50 条
  • [1] Short-Term Heart Rate Variability using Wrist-Worn Pulse Wave Monitor Compared to a Holter ECG
    Costin, Hariton
    Pasarica, Alexandru
    Alexa, Ioana-Dana
    Ilie, Adina Carmen
    Rotariu, Cristian
    Costin, Diana
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 635 - 638
  • [2] Forecasting of heart rate variability using wrist-worn heart rate monitor based on Hidden Markov Model
    Yun, Sanghun
    Son, Chang-Sik
    Lee, Sang-Ho
    Kang, Won-Seok
    2018 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2018, : 408 - 409
  • [3] Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables
    Baek, Hyun Jae
    Shin, JaeWook
    JOURNAL OF MEDICAL SYSTEMS, 2017, 41 (10)
  • [4] Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables
    Hyun Jae Baek
    JaeWook Shin
    Journal of Medical Systems, 2017, 41
  • [5] Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection
    Rinne, Juha K. A.
    Miri, Seyedsadra
    Oksala, Niku
    Vehkaoja, Antti
    Kossi, Jyrki
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (01) : 45 - 53
  • [6] Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection
    Juha K. A. Rinne
    Seyedsadra Miri
    Niku Oksala
    Antti Vehkaoja
    Jyrki Kössi
    Journal of Clinical Monitoring and Computing, 2023, 37 : 45 - 53
  • [7] Short term time-domain heart rate analysis indicates reduced baroreceptor-related heart rate variability in brachycephalic dogs
    Vargas-Pinto, Pedro
    Parra-Forero, Daniela
    Raigoza, Natalia
    Rodriguez, Valeria
    Ortiz, Leonardo A.
    Florian, Nestor F.
    Guzman, Nicolas
    Pedraza-Toscano, Adriana
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2023, 123
  • [8] Short-term frequency and time domain analysis of heart rate variability in type I diabetic subjects
    Roithinger, FX
    Allinger, S
    Knoflach, P
    Punzengruber, C
    Pachinger, O
    WIENER KLINISCHE WOCHENSCHRIFT, 1996, 108 (05) : 133 - 136
  • [9] Stability over time of short-term heart rate variability
    Tuula H. Tarkiainen
    Kirsi L. Timonen
    Pekka Tiittanen
    Juha E. K. Hartikainen
    Juha Pekkanen
    Gerard Hoek
    Angela Ibald-Mulli
    Esko J. Vanninen
    Clinical Autonomic Research, 2005, 15 : 394 - 399
  • [10] Stability over time of short-term heart rate variability
    Tarkiainen, TH
    Timonen, KL
    Tiittanen, P
    Hartikainen, JEK
    Pekkanen, J
    Hoek, G
    Ibald-Mulli, A
    Vanninen, EJ
    CLINICAL AUTONOMIC RESEARCH, 2005, 15 (06) : 394 - 399