A fast method for rescaling voxel S values for arbitrary voxel sizes in targeted radionuclide therapy from a single Monte Carlo calculation

被引:13
作者
Fernandez, Maria [1 ]
Haenscheid, Heribert [1 ]
Mauxion, Thibault [2 ]
Bardies, Manuel [2 ]
Kletting, Peter [3 ]
Glatting, Gerhard [4 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, D-97080 Wurzburg, Germany
[2] Ctr Rech Cancerol Toulouse, UPS, INSERM, UMR 1037, F-31062 Toulouse, France
[3] Univ Ulm, Dept Nucl Med, D-89081 Ulm, Germany
[4] Heidelberg Univ, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
Voxel S values (VSVs); Monte-Carlo simulation; targeted radionuclide therapy (TRT); internal dosimetry; NONUNIFORM ACTIVITY DISTRIBUTIONS; DOSE CALCULATIONS; DOSIMETRY; ENERGIES; PHANTOMS; ADULT; CODES;
D O I
10.1118/1.4812684
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In targeted radionuclide therapy, patient-specific dosimetry based on voxel S values (VSVs) is preferable to dosimetry based on mathematical phantoms. Monte-Carlo (MC) simulations are necessary to deduce VSVs for those voxel sizes required by quantitative imaging. The aim of this study is, starting from a single set of high-resolution VSVs obtained by MC simulations for a small voxel size along one single axis perpendicular to the source voxel, to present a suitable method to accurately calculate VSVs for larger voxel sizes. Methods: Accurate sets of VSVs for target voxel to source voxel distances up to 10 cm were obtained for high-resolution voxel sizes (0.5 mm for electrons and 1.0 mm for photons) from MC simulations for Y-90, Lu-177, and I-131 using the radiation transport code MCNPX v.2.7a. To make these values suitable to any larger voxel size, different analytical methods (based on resamplings, interpolations, and fits) were tested and compared to values obtained by direct MC simulations. As a result, an optimal calculation procedure is proposed. This procedure consisted of: (1) MC simulation for obtaining of a starting set of VSVs along a single line of voxels for a small voxel size for each radionuclide and type of radiation; (2) interpolation within the values obtained in point (1) for obtaining the VSVs for voxels within a spherical volume; (3) resampling of the data obtained in (1) and (2) for obtaining VSVs for voxels sizes larger than the one used for the MC calculation for integer voxel ratios (voxel ratio = new voxel size/voxel size MC simulation); (4) interpolation on within the data obtained in (3) for integer voxel ratios. The results were also compared to results from other authors. Results: The results obtained with the method proposed in this work show deviations relative to the source voxel below 1% for I-131 and Lu-177 and below 1.5% for Y-90 as compared with values obtained by direct MC simulations for voxel sizes ranging between 1.0 and 10.0 cm. The results obtained in this work show differences between the scored deposited energy and the emitted energy lower than 2% for electron radiation. Higher differences, attributable to the short considered radius of 10 cm in comparison with their penetration, can be found for photons. The authors' results agree well with previously published data obtained by other authors using different methods. Conclusions: A reliable and fast approach for obtaining accurate VSVs for voxel sizes larger than the voxel size used for the MC calculation of the starting set of high-resolution VSVs was developed and successfully tested for three different radionuclides of interest for targeted radiotherapy: one pure beta (Y-90) and 2 beta-gamma emitters (Lu-177 und I-131). Applying the method of this work allows any interested reader to repeat the calculations for arbitrary radionuclides of interest and/or smaller high-resolution voxel sizes, provided the means for running MC simulations are available. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 17 条
[1]  
Bolch WE, 1999, J NUCL MED, V40, p11S
[2]   Improvement of internal dose calculations using mathematical models of different adult heights [J].
Clairand, I ;
Bouchet, LG ;
Ricard, M ;
Durigon, M ;
Di Paola, M ;
Aubert, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2771-2785
[3]   Fine-Resolution Voxel S Values for Constructing Absorbed Dose Distributions at Variable Voxel Size [J].
Dieudonne, Arnaud ;
Hobbs, Robert F. ;
Bolch, Wesley E. ;
Sgouros, George ;
Gardin, Isabelle .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (10) :1600-1607
[4]  
Eckerman KF., 2008, MIRD: Radionuclide Data and Decay Schemes, V2nd
[5]   Nuclear medicine dosimetry: Quantitative imaging and dose calculations [J].
Glatting, Gerhard ;
Lassmann, Michael .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (04) :246-247
[6]   Revisions to the ORNL series of adult and pediatric computational phantoms for use with the mird schema [J].
Han, EY ;
Bolch, WE ;
Eckerman, KF .
HEALTH PHYSICS, 2006, 90 (04) :337-356
[7]   Differences in predicted and actually absorbed doses in peptide receptor radionuclide therapy [J].
Kletting, Peter ;
Mueller, Berthold ;
Erentok, Bahar ;
Schmaljohann, Joern ;
Behrendt, Florian F. ;
Reske, Sven N. ;
Mottaghy, Felix M. ;
Glatting, Gerhard .
MEDICAL PHYSICS, 2012, 39 (09) :5708-5717
[8]   A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions [J].
Lanconelli, N. ;
Pacilio, M. ;
Lo Meo, S. ;
Botta, F. ;
Di Dia, A. ;
Torres Aroche, L. A. ;
Coca Perez, M. A. ;
Cremonesi, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02) :517-533
[9]   Monte Carlo-assisted voxel source kernel method (MAVSK) for internal beta dosimetry [J].
Liu, A ;
Williams, LE ;
Wong, JYC ;
Raubitschek, AA .
NUCLEAR MEDICINE AND BIOLOGY, 1998, 25 (04) :423-433
[10]   Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV [J].
Maigne, L. ;
Perrot, Y. ;
Schaart, D. R. ;
Donnarieix, D. ;
Breton, V. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (03) :811-827