Material differentiation in forensic radiology with single-source dual-energy computed tomography

被引:33
作者
Ruder, Thomas D. [1 ,2 ,3 ]
Thali, Yannick [1 ,3 ]
Bolliger, Stephan A. [4 ,5 ]
Somaini-Mathier, Sandra [3 ,6 ]
Thali, Michael J. [1 ]
Hatch, Gary M. [3 ,7 ,8 ]
Schindera, Sebastian T. [2 ,9 ]
机构
[1] Univ Zurich, Inst Forens Med, Dept Forens Med & Imaging, CH-8057 Zurich, Switzerland
[2] Univ Hosp Bern, Inst Diagnost & Intervent Radiol, CH-3010 Bern, Switzerland
[3] Univ Bern, Ctr Forens Imaging & Virtopsy, Inst Forens Med, CH-3012 Bern, Switzerland
[4] Cantonal Hosp, Dept Forens Med, Forens Serv, Aarau, Switzerland
[5] Univ Bern, Dept Forens Pathol, Inst Forens Med, CH-3012 Bern, Switzerland
[6] Univ Hosp Bern, Dept Diagnost & Intervent Neuroradiol, CH-3010 Bern, Switzerland
[7] Univ New Mexico, Radiol Pathol Ctr Forens Imaging, Dept Radiol, Albuquerque, NM 87102 USA
[8] Univ New Mexico, Radiol Pathol Ctr Forens Imaging, Dept Pathol, Albuquerque, NM 87102 USA
[9] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
关键词
Forensic radiology; Identification; Foreign objects; Dual-energy CT; Single-source dual-energy CT; Virtopsy; CT; IDENTIFICATION; FEASIBILITY; ARTIFACTS;
D O I
10.1007/s12024-012-9398-y
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The goal of this study was to investigate the use of dual-energy computed tomography (CT) in differentiating frequently encountered foreign material on CT images using a standard single-source CT scanner. We scanned 20 different, forensically relevant materials at two X-Ray energy levels (80 and 130 kVp) on CT. CT values were measured in each object at both energy levels. Intraclass correlation coefficient (ICC) was used to determine intra-reader reliability. Analysis of variance (ANOVA) was performed to assess significance levels between X-Ray attenuation at 80 and 130 kVp. T test was used to investigate significance levels between mean HU values of individual object pairings at single energy levels of 80 and 130 kVp, respectively. ANOVA revealed that the difference in attenuation between beam energies of 80 kVp compared to 130 kVp was statistically significant (p < 0.005) for all materials except brass and lead. ICC was excellent at 80 kVp (0.999, p < 0.001) and at 130 kVp (0.998, p < 0.001). T test showed that using single energy levels of 80 and 130 kVp respectively 181/190 objects pairs could be differentiated from one another based on HU measurements. Using the combined information from both energy levels, 189/190 object pairs could be differentiated. Scanning with different energy levels is a simple way to apply dual-energy technique on a regular single-energy CT and improves the ability to differentiate foreign bodies with CT, based on their attenuation values.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 21 条
[1]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[2]   Is Differentiation of Frequently Encountered Foreign Bodies in Corpses Possible by Hounsfield Density Measurement? [J].
Bolliger, Stephan A. ;
Oesterhelweg, Lars ;
Spendlove, Danny ;
Ross, Steffen ;
Thali, Michael J. .
JOURNAL OF FORENSIC SCIENCES, 2009, 54 (05) :1119-1122
[3]  
Brogdon BG, 1998, FORENSIC RADIOLOGY, P13
[4]  
Brogdon BG, 1998, FORENSIC RADIOLOGY, P35
[5]   Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging? [J].
Coursey, Courtney A. ;
Nelson, Rendon C. ;
Boll, Daniel T. ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Neville, Amy M. ;
Marin, Daniele ;
Gupta, Rajan T. ;
Schindera, Sebastian T. .
RADIOGRAPHICS, 2010, 30 (04) :1037-1055
[6]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[7]   Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels [J].
Guggenberger, R. ;
Winklhofer, S. ;
Osterhoff, G. ;
Wanner, G. A. ;
Fortunati, M. ;
Andreisek, G. ;
Alkadhi, H. ;
Stolzmann, P. .
EUROPEAN RADIOLOGY, 2012, 22 (11) :2357-2364
[8]  
Huda W., 2003, Radiologic Physics, V2, P121
[9]   Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT-3D color encoded automatic discrimination of dental restorations [J].
Jackowski, C ;
Lussi, A ;
Classens, M ;
Kilchoer, T ;
Bolliger, S ;
Aghayev, E ;
Criste, A ;
Dirnhofer, R ;
Thali, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) :510-513
[10]  
Jackowski C, 2009, VIRTOPSY APPROACH, P169