Multicentre evaluation of Ziehl-Neelsen and light-emitting diode fluorescence microscopy in China

被引:46
作者
Xia, H. [1 ]
Song, Y-Y. [1 ]
Zhao, B. [1 ]
Kam, K-M. [2 ]
O'Brien, R. J. [3 ]
Zhang, Z-Y. [4 ]
Sohn, H. [5 ]
Wang, W. [6 ]
Zhao, Y-L. [1 ]
机构
[1] Chinese Ctr Dis Control & Prevent, Natl TB Reference Lab, Natl Ctr TB Control & Prevent, Beijing 102206, Peoples R China
[2] Ctr Hlth Protect, TB Reference Lab, Publ Hlth Lab Serv Branch, Dept Hlth, Hong Kong, Hong Kong, Peoples R China
[3] Fdn Innovat New Diagnost, Geneva, Switzerland
[4] China Off, Program Appropriate Technol Hlth, Beijing, Peoples R China
[5] McGill Univ, Dept Epidemiol & Biostat, Montreal, PQ, Canada
[6] Ritsumeican Univ, Grad Sch Policy Sci, Kyoto, Japan
基金
比尔及梅琳达.盖茨基金会;
关键词
pulmonary tuberculosis; smear microscopy; light-emitting diode fluorescence microscopy; TUBERCULOSIS;
D O I
10.5588/ijtld.12.0184
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: To assess the feasibility of using light-emitting diode fluorescence microscopy (LED-FM) in peripheral laboratories in China. DESIGN: The performance of LED-FM and Ziehl-Neelsen (ZN) microscopy was compared on slides directly prepared from the sputum of tuberculosis (TB) suspects and follow-up patients on treatment. The examination time, fading of fluorescence-stained slides, average unit cost and qualitative user appraisal of LED-FM were also analysed. RESULTS: Among 11 276 slides, the smear-positive rate for LED-FM was 11.2% (1263/11276), 2.6% (294/11 276) higher than that of ZN (8.6%, 969/11276; chi(2)263.5, P < 0.05). The examination time for LED-FM (120.0 +/- 38.9 seconds) was shorter than that for ZN (206.3 +/- 75.9 s; t = 28.12, P < 0.05). For smear fading, quantitative and qualitative errors occurred within respectively 7.8 and 7.7 weeks. The average unit costs for ZN and LED-FM were respectively US$2.20 +/- 0.58 and US$1.97 +/- 0.71 (t = 5.08, P < 0.05). LED-FM was accepted by most laboratory technicians. CONCLUSION: LED-FM compared favourably with ZN, with a higher smear-positive detection rate, a shorter examination time and lower unit examination cost. LED-FM may be an alternative to ZN as a cost-effective method for detecting bacilli in peripheral laboratories in China.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 11 条
[1]   Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda [J].
Albert, Heidi ;
Manabe, Yukari ;
Lukyamuzi, George ;
Ademun, Patrick ;
Mukkada, Sheena ;
Nyesiga, Barnabas ;
Joloba, Moses ;
Paramasivan, C. N. ;
Perkins, Mark D. .
PLOS ONE, 2010, 5 (12)
[2]   Performance of LED-Based Fluorescence Microscopy to Diagnose Tuberculosis in a Peripheral Health Centre in Nairobi [J].
Bonnet, Maryline ;
Gagnidze, Laramie ;
Githui, Willie ;
Guerin, Philippe Jean ;
Bonte, Laurence ;
Varaine, Francis ;
Ramsay, Andrew .
PLOS ONE, 2011, 6 (02)
[3]  
Cambanis A, 2007, INT J TUBERC LUNG D, V11, P40
[4]  
Mase SR, 2007, INT J TUBERC LUNG D, V11, P485
[5]   Fading of Auramine-Stained Mycobacterial Smears and Implications for External Quality Assurance [J].
Minion, Jessica ;
Shenai, Shubhada ;
Vadwai, Viral ;
Tipnis, Tejashree ;
Greenaway, Christina ;
Menzies, Dick ;
Ramsay, Andrew ;
Rodrigues, Camilla ;
Pai, Madhukar .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) :2024-2026
[6]  
RICHARDS OSCAR W., 1941, SCIENCE, V93, P190, DOI 10.1126/science.93.2408.190
[7]  
RICHARDS OSCAR W., 1941, AMER REV TUBERC, V44, P255
[8]  
Sohn H, 2009, INT J TUBERC LUNG D, V13, P266
[9]   TB diagnostic tests: how do we figure out their costs? [J].
Sohn, Hojoon ;
Minion, Jessica ;
Albert, Heidi ;
Dheda, Keertan ;
Pai, Madhukar .
EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2009, 7 (06) :723-733
[10]  
World Health Organization, 2011, WHOHTMTB20118