Structural Health Monitoring in Smart Structures Through Time Series Analysis

被引:31
作者
da Silva, Samuel [1 ]
Dias Junior, Milton [1 ]
Lopes Junior, Vicente [2 ]
机构
[1] Univ Estadual Campinas, Dept Mech Design, Fac Mech Engn, BR-13083970 Campinas, SP, Brazil
[2] UNESP, Dept Mech Engn, Grp Mat & Sistemas Inteligentes, BR-15385000 Ilha Solteira, SP, Brazil
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2008年 / 7卷 / 03期
基金
巴西圣保罗研究基金会;
关键词
damage detection; damage metric; PZT patches; electrical impedance; statistical process control;
D O I
10.1177/1475921708090561
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the application of a structural health monitoring technique based on electrical measurements obtained by piezoceramics (PZT) patches bonded in lightweight structures. The goal is to detect and locate imminent structural change occurrence with statistical confidence through a nondestructive evaluation test. Though the major focus in damage detection is given by monitoring electrical impedance in frequency-domain, the current research work applies a novel approach based on time-series. In such case, auto-regressive moving average with exogenous input (ARMAX) system identification models and statistical process control (SPC) charts are used for linear prediction to detect and locate damages. In order to compare the results, the classical damage metric chart obtained by frequency response from input-output data is described. The efficacy of the proposed approach is demonstrated through experimental tests.
引用
收藏
页码:231 / 244
页数:14
相关论文
共 17 条