Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1

被引:145
作者
Rong, Zhen [1 ,2 ]
Wang, Qiong [3 ]
Sun, Nanxi [1 ]
Jia, Xiaofei [1 ,4 ]
Wang, Keli [1 ,5 ]
Xiao, Rui [1 ,2 ]
Wang, Shengqi [1 ,2 ]
机构
[1] Beijing Inst Radiat Med, Beijing 100850, Peoples R China
[2] Beijing Key Lab New Mol Diag Technol Infect Dis, Beijing 100850, Peoples R China
[3] Beijing Meiling Biotechnol Corp, Beijing 102600, Peoples R China
[4] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China
[5] Anhui Med Univ, Hefei 230032, Anhui, Peoples R China
关键词
Quantum dot microsphere; Lateral flow immunoassay; Smartphone; Point-of-care; Zika virus nonstructural protein 1; QUANTUM-DOT NANOBEADS; QUANTITATIVE DETECTION; HIGH-THROUGHPUT; IMMUNOCHROMATOGRAPHIC ASSAY; MULTIPLEXED DETECTION; EBOLA-VIRUS; DIAGNOSIS; AMPLIFICATION; STRIP; NANOPARTICLES;
D O I
10.1016/j.aca.2018.12.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simple, inexpensive, and rapid diagnostic tests in low-resource settings with limited laboratory equipment and technical expertise are instrumental in reducing morbidity and mortality from epidemic infectious diseases. We developed a smartphone-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive point-of-care detection of Zika virus nonstructural protein 1 (ZIKV NS1). An attachment was designed and 3D-printed to integrate the smartphone with external optical and electrical components, enabling the miniaturization of the instrument and reduction in cost and complexity. Quantum dot microspheres were utilized as probes in fluorescent LFIA because of their extremely bright fluorescence signal. This approach can achieve quantitative point-of-care detection of ZIKV NS1 within 20 min. Limits of detection (LODs) in buffer and serum were 0.045 and 0.15 ng mL(-1), respectively. Despite the high structural similarity, a high-level Dengue virus NS1 as interferent showed limited cross-reactivity. Furthermore, this assay was successfully applied to detecte ZIKV NS1 and virions spiked in complex biological samples, indicating its practical application capability. Given its low cost, compact size, and excellent analytical performance, the proposed smartphone-based fluorescent LFIA platform holds considerable potential in rapid and accurate point-of-care detection of ZIKV NS1 and provides new insight into the design and application of molecular diagnostic methods in low-resource settings. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 50 条
[1]   Novel graphene-based biosensor for early detection of Zika virus infection [J].
Afsahi, Savannah ;
Lerner, Mitchell B. ;
Goldstein, Jason M. ;
Lee, Joo ;
Tang, Xiaoling ;
Bagarozzi, Dennis A., Jr. ;
Pan, Deng ;
Locascio, Lauren ;
Walker, Amy ;
Barron, Francie ;
Goldsmith, Brett R. .
BIOSENSORS & BIOELECTRONICS, 2018, 100 :85-88
[2]   Antibody-based assay discriminates Zika virus infection from other flaviviruses [J].
Balmaseda, Angel ;
Stettler, Karin ;
Medialdea-Carrera, Raquel ;
Collado, Damaris ;
Jin, Xia ;
Zambrana, Jose Victor ;
Jaconi, Stefano ;
Cameroni, Elisabetta ;
Saborio, Saira ;
Rovida, Francesca ;
Percivalle, Elena ;
Ijaz, Samreen ;
Dicks, Steve ;
Ushiro-Lumb, Ines ;
Barzon, Luisa ;
Siqueira, Patricia ;
Brown, David W. G. ;
Baldanti, Fausto ;
Tedder, Richard ;
Zambon, Maria ;
de Filippis, A. M. Bispo ;
Harris, Eva ;
Corti, Davide .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (31) :8384-8389
[3]   Cellphone-Based Hand-Held Microplate Reader for Point-of-Care Testing of Enzyme-Linked Immunosorbent Assays [J].
Berg, Brandon ;
Cortazar, Bingen ;
Tseng, Derek ;
Ozkan, Haydar ;
Feng, Steve ;
Wei, Qingshan ;
Chan, Raymond Yan-Lok ;
Burbano, Jordi ;
Farooqui, Qamar ;
Lewinski, Michael ;
Di Carlo, Dino ;
Garner, Omai B. ;
Ozcan, Aydogan .
ACS NANO, 2015, 9 (08) :7857-7866
[4]   Rapid antigen tests for dengue virus serotypes and Zika virus in patient serum [J].
Bosch, Irene ;
de Puig, Helena ;
Hiley, Megan ;
Carre-Camps, Marc ;
Perdomo-Celis, Federico ;
Narvaez, Carlos F. ;
Salgado, Doris M. ;
Senthoor, Dewahar ;
O'Grady, Madeline ;
Phillips, Elizabeth ;
Durbin, Ann ;
Fandos, Diana ;
Miyazaki, Hikaru ;
Yen, Chun-Wan ;
Gelvez-Ramirez, Margarita ;
Warke, Rajas V. ;
Ribeiro, Lucas S. ;
Teixeira, Mauro M. ;
Almeida, Roque P. ;
Munoz-Medina, Jose E. ;
Ludert, Juan E. ;
Nogueira, Mauricio L. ;
Colombo, Tatiana E. ;
Terzian, Ana C. B. ;
Bozza, Patricia T. ;
Calheiros, Andrea S. ;
Vieira, Yasmine R. ;
Barbosa-Lima, Giselle ;
Vizzoni, Alexandre ;
Cerbino-Neto, Jose ;
Bozza, Fernando A. ;
Souza, Thiago M. L. ;
Trugilho, Monique R. O. ;
de Filippis, Ana M. B. ;
de Sequeira, Patricia C. ;
Marques, Ernesto T. A. ;
Magalhaes, Tereza ;
Diaz, Francisco J. ;
Restrepo, Berta N. ;
Marin, Katerine ;
Mattar, Salim ;
Olson, Daniel ;
Asturias, Edwin J. ;
Lucera, Mark ;
Singla, Mohit ;
Medigeshi, Guruprasad R. ;
de Bosch, Norma ;
Tam, Justina ;
Gomez-Marquez, Jose ;
Clavet, Charles .
SCIENCE TRANSLATIONAL MEDICINE, 2017, 9 (409)
[5]   A Serological Point-of-Care Test for the Detection of IgG Antibodies against Ebola Virus in Human Survivors [J].
Brangel, Polina ;
Sobarzo, Ariel ;
Parolo, Claudio ;
Miller, Benjamin S. ;
Howes, Philip D. ;
Gelkop, Sigal ;
Lutwarna, Julius J. ;
Dye, John M. ;
McKendry, Rachel A. ;
Lobel, Leslie ;
Stevens, Molly M. .
ACS NANO, 2018, 12 (01) :63-73
[6]   Zika Immunoassay Based on Surface-Enhanced Raman Scattering Nanoprobes [J].
Camacho, Sabrina A. ;
Sobral-Filho, Regivaldo Gomes ;
Aoki, Pedro Henrique B. ;
Constantino, Carlos Jose L. ;
Brolo, Alexandre G. .
ACS SENSORS, 2018, 3 (03) :587-594
[7]   Mobile Platform for Multiplexed Detection and Differentiation of Disease-Specific Nucleic Acid Sequences, Using Microfluidic Loop-Mediated Isothermal Amplification and Smartphone Detection [J].
Chen, Weili ;
Yu, Hojeong ;
Sun, Fu ;
Ornob, Akid ;
Brisbin, Ryan ;
Ganguli, Anurup ;
Vemuri, Vinay ;
Strzebonski, Piotr ;
Cui, Guangzhe ;
Allen, Karen J. ;
Desai, Smit A. ;
Lin, Weiran ;
Nash, David M. ;
Hirschberg, David L. ;
Brooks, Ian ;
Bashir, Rashid ;
Cunningham, Brian T. .
ANALYTICAL CHEMISTRY, 2017, 89 (21) :11219-11226
[8]   A gold immunochromatographic assay for the rapid and simultaneous detection of fifteen β-lactams [J].
Chen, Yanni ;
Wang, Yongwei ;
Liu, Liqiang ;
Wu, Xiaoling ;
Xu, Liguang ;
Kuang, Hua ;
Li, Aike ;
Xu, Chuanlai .
NANOSCALE, 2015, 7 (39) :16381-16388
[9]   A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection [J].
Di Nardo, F. ;
Anfossi, L. ;
Giovannoli, C. ;
Passini, C. ;
Goftman, V. V. ;
Goryacheva, I. Y. ;
Baggiani, C. .
TALANTA, 2016, 150 :463-468
[10]   Nanozyme-strip for rapid local diagnosis of Ebola [J].
Duan, Demin ;
Fan, Kelong ;
Zhang, Dexi ;
Tan, Shuguang ;
Liang, Mifang ;
Liu, Yang ;
Zhang, Jianlin ;
Zhang, Panhe ;
Liu, Wei ;
Qiu, Xiangguo ;
Kobinger, Gary P. ;
Gao, George Fu ;
Yan, Xiyun .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :134-141