T2Bacteria magnetic resonance assay for the rapid detection of ESKAPEc pathogens directly in whole blood

被引:65
|
作者
De Angelis, Giulia [1 ]
Posteraro, Brunella [2 ]
De Carolis, Elena [1 ]
Menchinelli, Giulia [1 ]
Franceschi, Francesco [3 ]
Tumbarello, Mario [4 ]
De Pascale, Gennaro [5 ]
Spanu, Teresa [1 ]
Sanguinetti, Maurizio [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Inst Microbiol, Fdn Policlin Univ Agostino Gemelli, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Inst Publ Hlth, Fdn Policlin Univ Agostino Gemelli, Sect Hyg, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Dept Emergency Med, Fdn Policlin Univ Agostino Gemelli, Rome, Italy
[4] Univ Cattolica Sacro Cuore, Inst Infect Dis, Fdn Policlin Univ Agostino Gemelli, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Dept Anaesthesiol & Intens Care, Fdn Policlin Univ Agostino Gemelli, Rome, Italy
关键词
INTERNATIONAL CONSENSUS DEFINITIONS; STREAM INFECTIONS; SEPTIC SHOCK; MOLECULAR DIAGNOSIS; CRITICALLY-ILL; SEPSIS; IDENTIFICATION; THERAPY; ONSET; TIME;
D O I
10.1093/jac/dky049
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To evaluate the magnetic resonance-based T2Bacteria Panel assay for direct detection of ESKAPEc (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa and Escherichia coli) pathogens in blood samples of patients with suspected bloodstream infection (BSI). Patients and methods: Adult patients admitted to the Emergency Medicine Department, Infectious Diseases Unit and ICU of a large tertiary-care hospital were included if they had a blood culture (BC) ordered concomitantly with a whole-blood sample for T2Bacteria testing. Results were compared with those of BC and other clinically relevant information. Results: A total of 140 samples from 129 BSI patients were studied. Single bacteria were detected in 15.7% (22/140) and 12.1% (17/140), and multiple bacteria in 2.9% (4/140) and 1.4% (2/140), of samples tested by T2Bacteria and BC, respectively. With respect to the six target (ESKAPEc) species, overall sensitivity and specificity of T2Bacteria across all detection channels in comparison with BC were 83.3% and 97.6%, respectively; these values increased to 89.5% and 98.4%, respectively, when a true-infection criterion (i.e. the same microorganism detected only by T2Bacteria was cultured from another sample type reflecting the source of infection) was used as the comparator. There were 808 T2Bacteria detection results across 112 samples, with concordant negative results, yielding a negative predictive value of 99.8%. The mean time to negative result was 6.1 +/- 1.5 h, whereas the mean time to detection/species identification was 5.5 +/- 1.4 h. Conclusions: The T2Bacteria Panel assay has the potential to provide accurate and timely diagnosis of ESKAPEc bacteraemia, which might support the direct therapeutic management of BSI patients.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [31] Evaluation of a rapid bedside immunochromatographic assay for detection of cardiac troponin I in whole blood
    Pagani, F
    Serena, C
    Bosio, C
    Cuccia, C
    Panteghini, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (05) : 458 - 459
  • [32] Development of a rapid recombinase polymerase amplification assay for the detection of Streptococcus pneumoniae in whole blood
    Clancy, Eoin
    Higgins, Owen
    Forrest, Matthew S.
    Boo, Teck Wee
    Cormican, Martin
    Barry, Thomas
    Piepenburg, Olaf
    Smith, Terry J.
    BMC INFECTIOUS DISEASES, 2015, 15
  • [33] Development of a rapid recombinase polymerase amplification assay for the detection of Streptococcus pneumoniae in whole blood
    Eoin Clancy
    Owen Higgins
    Matthew S. Forrest
    Teck Wee Boo
    Martin Cormican
    Thomas Barry
    Olaf Piepenburg
    Terry J. Smith
    BMC Infectious Diseases, 15
  • [34] In-depth analysis of T2Bacteria positive results in patients with concurrent negative blood culture: a case series
    Markos Kalligeros
    Ioannis M. Zacharioudakis
    Giannoula S. Tansarli
    Katerina Tori
    Fadi Shehadeh
    Eleftherios Mylonakis
    BMC Infectious Diseases, 20
  • [35] Cardiac troponin T: Comparison of a whole blood ''rapid assay'' with the ES 300 assay in cardiac patients.
    Alonsozana, GL
    Jacobs, E
    Fitzgerald, RL
    Frankel, WL
    Ochs, L
    Christenson, RH
    CLINICAL CHEMISTRY, 1996, 42 (06) : 349 - 349
  • [36] RAPID TROPONIN T MEASUREMENT IN WHOLE-BLOOD FOR DETECTION OF MYOCARDIAL DAMAGE
    COLLINSON, P
    THOMAS, S
    SIU, LS
    STUBBS, P
    CANEPAANSON, R
    CLINICAL CHEMISTRY, 1995, 41 (06) : S164 - S164
  • [37] Rapid detection of cancer-related cfc-DNA biomarkers directly from whole blood
    Heller, Michael James
    Sonnenberg, Avery
    JOURNAL OF CLINICAL ONCOLOGY, 2012, 30 (30)
  • [38] A rapid, highly sensitive and culture-free detection of pathogens from whole blood by removal of white blood cells using immuno-magnetic beads
    Vutukuru, Manjula Ramya
    Sharma, Divya Khandige
    Ragavendar, M. S.
    Mitra, Nivedita
    JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 127 : 59 - 61
  • [39] Rapid flow cytometric whole blood assay for assessment of SARS-CoV-2-reactive T cell immunity
    Fuelle, Lorenz
    Gert, Philipp David
    Traska, Verena
    Chatzopoulou, Sofia
    Dose, Christian
    Richter, Anne
    Schuster, Marc
    CANCER RESEARCH, 2022, 82 (12)
  • [40] Field evaluation of a rapid immunochromatographic assay for detection of Trypanosoma cruzi infection by use of whole blood
    Roddy, Paul
    Goiri, Javier
    Flevaud, Laurence
    Pablo Palma, Pedro
    Morote, Silvia
    Lima, Nines
    Villa, Luis
    Torrico, Faustino
    Albajar-Vinas, Pedro
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (06) : 2022 - 2027