Facade design principles for nearly zero energy buildings in a cold climate

被引:130
作者
Thalfeldt, Martin [1 ]
Pikas, Ergo [1 ]
Kurnitski, Jarek [1 ]
Voll, Hendrik [2 ]
机构
[1] Tallinn Univ Technol, Dept Struct Engn, Fac Civil Engn, EE-19086 Tallinn, Estonia
[2] Tallinn Univ Technol, Dept Environm Engn, Fac Civil Engn, EE-19086 Tallinn, Estonia
关键词
Facade design; Windows; Fenestration; Daylight; Nearly zero energy buildings; Cost optimality; Energy simulations; OFFICE BUILDINGS; PERFORMANCE; FENESTRATION; SIMULATION;
D O I
10.1016/j.enbuild.2013.08.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cost optimal and as energy efficient as possible facade solutions, including window properties, external wall insulation, window-to-wall ratio and external shading were determined with energy and daylight simulations in the cold climate of Estonia. Heating dominated in the energy balance and therefore windows with higher number of panes and low emissivity coatings improved energy performance. The window sizes resulting in best energy performance for double and triple glazing were as small as daylight requirements allow, 22-24% respectively. For quadruple and hypothetical quintuple glazing the optimal window-to-wall ratios were larger, about 40% and 60% respectively, because of daylight utilization and good solar factor naturally provided by so many panes. The cost optimal facade solution was highly transparent triple low emissivity glazing with window-to-wall ratios of about 25% and external wall insulation thickness of 200 mm (U=0.16). Dynamic external shading gave positive effect on energy performance only in case of large window sizes whereas due to high investment cost it was not financially feasible. Limited number of simulations with Central European climate showed that triple glazing with double low emissivity coating and window-to-wall ratio of about 40%, i.e. slightly larger and with external shading compared to Estonian cost optimal one, clearly outperformed conventional design. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:309 / 321
页数:13
相关论文
共 19 条
[1]  
[Anonymous], 2003, ISO 15099
[2]  
Beck W., 2010, REHVA GUIDEBOOK 12
[3]  
Boyano A., 2004, ENERG BUILDINGS, V36, P117
[4]  
Franzetti C., 2013, ENERG BUILDINGS, V656, P19
[5]   Windows in the buildings of tomorrow: Energy losers or energy gainers? [J].
Grynning, Steinar ;
Gustavsen, Arild ;
Time, Berit ;
Jelle, Bjorn Petter .
ENERGY AND BUILDINGS, 2013, 61 :185-192
[6]  
Hani A., 2012, Smart Grid Renew. Energy, V3, P222, DOI DOI 10.4236/SGRE.2012.33031
[7]  
HERNANDEZ O, 2011, REHVA EUROPEAN HVAC, V48, P53
[8]  
IDA-ICE, IDA IND CLIM EN 4 5
[9]   GLAZING ENERGY PERFORMANCE AND DESIGN OPTIMIZATION WITH DAYLIGHTING [J].
JOHNSON, R ;
SULLIVAN, R ;
SELKOWITZ, S ;
NOZAKI, S ;
CONNER, C ;
ARASTEH, D .
ENERGY AND BUILDINGS, 1984, 6 (04) :305-317
[10]  
Kalamees T, 2006, P EST ACAD SCI, V12, P40