High-resolution cerebral blood volume imaging in humans using the blood pool contrast agent ferumoxytol

被引:48
作者
Christen, Thomas [1 ]
Ni, Wendy [1 ,2 ]
Qiu, Deqiang [1 ]
Schmiedeskamp, Heiko [1 ]
Bammer, Roland [1 ]
Moseley, Michael [1 ]
Zaharchuk, Greg [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
cerebral blood volume; steady-state; dynamic susceptibility contrast; iron oxide; RAT FOREPAW STIMULATION; IN-VIVO; VESSEL SIZE; EX-VIVO; PERFUSION; MRI; FLOW; QUANTIFICATION; ANGIOGENESIS; GADOTERIDOL;
D O I
10.1002/mrm.24500
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cerebral blood volume maps are usually acquired using dynamic susceptibility contrast imaging which inherently limits the spatial resolution and signal to noise ratio of the images. In this study, we used ferumoxytol (AMAG Pharmaceuticals, Inc., Cambridge, MA), an FDA-approved compound, to obtain high-resolution cerebral blood volume maps with a steady-state approach in seven healthy volunteers. R-2(*) maps (0.8 x 0.8 x 1 mm(3)) were acquired before and after injection of ferumoxytol and an intraindividual normalization protocol was used to obtain quantitative values. The results show excellent contrast between white and gray matter as well as fine highly detailed vascular structures. An average blood volume of 4% was found in the brain of all volunteers, consistent with prior literature values. A linear relationship was found between ferumoxytol dose (mg/kg) and R-2(*) (1/s) in gray (R-2 = 0.98) and white matter (R-2 = 0.98). A quadratic relationship was found in the sagittal sinus (R-2 = 0.98). The cerebral blood volume maps compare well with lower resolution dynamic susceptibility contrast-MRI and their use should improve the evaluation of small and heterogeneous lesions and facilitate intrapatient and interpatient comparisons. Magn Reson Med 70:705-710, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:705 / 710
页数:6
相关论文
共 40 条
[1]   Methodology of brain perfusion imaging [J].
Barbier, EL ;
Lamalle, L ;
Décorps, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :496-520
[2]   Assessment of T1 and T*2 effects in vivo and ex vivo using iron oxide nanoparticles in steady state-dependence on blood volume and water exchange [J].
Bjornerud, A ;
Johansson, LO ;
Briley-Sæbo, K ;
Ahlström, HK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :461-471
[3]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[4]  
Calamante Fernando, 2010, Top Magn Reson Imaging, V21, P75, DOI 10.1097/RMR.0b013e31821e53f5
[5]   Measuring brain oxygenation in humans using a multiparametric quantitative blood oxygenation level dependent MRI approach [J].
Christen, Thomas ;
Schmiedeskamp, Heiko ;
Straka, Matus ;
Bammer, Roland ;
Zaharchuk, Greg .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) :905-911
[6]   MRI Using Ferumoxytol Improves the Visualization of Central Nervous System Vascular Malformations [J].
Dosa, Edit ;
Tuladhar, Suchita ;
Muldoon, Leslie L. ;
Hamilton, Bronwyn E. ;
Rooney, William D. ;
Neuwelt, Edward A. .
STROKE, 2011, 42 (06) :1581-1588
[7]   Magnetic resonance imaging of intracranial tumors: intra-patient comparison of gadoteridol and ferumoxytol [J].
Dosa, Edit ;
Guillaume, Daniel J. ;
Haluska, Marianne ;
Lacy, Cynthia A. ;
Hamilton, Bronwyn E. ;
Njus, Jeffrey M. ;
Rooney, William D. ;
Kraemer, Dale F. ;
Muldoon, Leslie L. ;
Neuwelt, Edward A. .
NEURO-ONCOLOGY, 2011, 13 (02) :251-260
[8]   Monitoring angiogenesis in brain using steady-state quantification of ΔR2 with MION infusion [J].
Dunn, JF ;
Roche, MA ;
Springett, R ;
Abajian, M ;
Merlis, J ;
Daghlian, CP ;
Lu, SY ;
Makki, M .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :55-61
[9]   POTENTIAL FOR DIFFERENTIATION OF PSEUDOPROGRESSION FROM TRUE TUMOR PROGRESSION WITH DYNAMIC SUSCEPTIBILITY-WEIGHTED CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING USING FERUMOXYTOL VS. GADOTERIDOL: A PILOT STUDY [J].
Gahramanov, Seymur ;
Raslan, Ahmed M. ;
Muldoon, Leslie L. ;
Hamilton, Bronwyn E. ;
Rooney, William D. ;
Varallyay, Csanad G. ;
Njus, Jeffrey M. ;
Haluska, Marianne ;
Neuwelt, Edward A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (02) :514-523
[10]   Comparative Analysis of Ferumoxytol and Gadoteridol Enhancement Using T1-and T2-Weighted MRI in Neuroimaging [J].
Hamilton, Bronwyn E. ;
Nesbit, Gary M. ;
Dosa, Edit ;
Gahramanov, Seymur ;
Rooney, Bill ;
Nesbit, Eric G. ;
Raines, Joshua ;
Neuwelt, Edward A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) :981-988