First comparison of performances between the new whole-body cadmium-zinc-telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial perfusion imaging: Analysis of phantom and patients

被引:10
作者
Morelle, Maxime [1 ]
Bellevre, Dimitri [2 ]
Hossein-Foucher, Claude [1 ]
Manrique, Alain [3 ,4 ]
Bailliez, Alban [2 ,3 ,5 ]
机构
[1] Univ Lille 2, CHRU Lille, Hop Roger Salengro, Dept Nucl Med, Lille, France
[2] Hop Prive Le Bois, IRIS, Dept Nucl Med, Lille, France
[3] Normandie Univ, UNICAEN, Signalisat Electrophysiol & Imagerie Les Ischem R, FHU REMOD VHF, Caen, France
[4] CHU Caen, Nucl Med, Caen, France
[5] Grp Hop Inst Catholique Lille, Dept Nucl Med, UF 5881, Lomme Les Lille, France
关键词
CZT-cameras; myocardial perfusion imaging; SPECT; VALIDATION; SYSTEM;
D O I
10.1007/s12350-019-01702-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Dedicated cardiac Cadmium-zinc-telluride (CZT) cameras show superior performances compared with Anger systems, particularly in terms of spatial resolution and count sensitivity. This study evaluated the performances of a new polyvalent whole body CZT camera (DNM 670CZT) compared with a cardiac dedicated CZT camera (DNM 530c) for myocardial perfusion SPECT. Methods The spatial resolution was evaluated with three linear sources filled with(99m)Tc. We used a cardiac phantom to evaluate count sensitivity, sharpness index, contrast-to-noise ratio, wall thickness, non-uniformity index, perfusion scores and ventricle volumes for both cameras. The impact of matrix size, and acquisition time was investigated. Concordance between the two cameras was evaluated in patients using QPS/QGS software for quantitative segmental perfusion, motion and thickness scores. Results The spatial resolution was identical with the two cameras. Count sensitivity of the DNM 670CZT was twofold lower compared with the DNM 530c, leading to lower sharpness index and contrast-to-noise ratio. The wall thickness and the myocardial volumes were similar. Visual and quantitative assessments of the perfusion patterns have shown a good concordance of the two cameras on phantoms and in patients. Conclusion This study demonstrated the feasibility of myocardial perfusion SPECT imaging using the new whole-body DNM 670CZT camera.
引用
收藏
页码:1261 / 1269
页数:9
相关论文
共 19 条
[1]   Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance [J].
Bailliez, Alban ;
Blaire, Tanguy ;
Mouquet, Frederic ;
Legghe, R. ;
Etienne, B. ;
Legallois, Damien ;
Agostini, Denis ;
Manrique, Alain .
JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (04) :712-722
[2]   First determination of the heart-to-mediastinum ratio using cardiac dual isotope (123I-MIBG/99mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study [J].
Bellevre, Dimitri ;
Manrique, Alain ;
Legallois, Damien ;
Bross, Samy ;
Baavour, Rafael ;
Roth, Nathaniel ;
Blaire, Tanguy ;
Desmonts, Cedric ;
Bailliez, Alban ;
Agostini, Denis .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) :1912-1919
[3]   Left ventricular function assessment using 123I/99mTc dual-isotope acquisition with two semi-conductor cadmium-zinc-telluride (CZT) cameras: a gated cardiac phantom study [J].
Blaire, Tanguy ;
Bailliez, Alban ;
Ben Bouallegue, Faycal ;
Bellevre, Dimitri ;
Agostini, Denis ;
Manrique, Alain .
EJNMMI PHYSICS, 2016, 3 (01)
[4]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[5]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[6]  
DEPUEY EG, 1994, J NUCL MED, V35, P699
[7]   Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera [J].
Duvall, W. Lane ;
Croft, Lori B. ;
Ginsberg, Eric S. ;
Einstein, Andrew J. ;
Guma, Krista A. ;
George, Titus ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) :847-857
[8]   Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology [J].
Erlandsson, Kjell ;
Kacperski, Krzysztof ;
van Gramberg, Dean ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2635-2649
[9]   Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese Patients [J].
Fiechter, Michael ;
Gebhard, Catherine ;
Fuchs, Tobias A. ;
Ghadri, Jelena R. ;
Stehli, Julia ;
Kazakauskaite, Egle ;
Herzog, Bernhard A. ;
Pazhenkottil, Aju P. ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (09) :1401-1406
[10]   A Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera [J].
Gambhir, Sanjiv S. ;
Berman, Daniel S. ;
Ziffer, Jack ;
Nagler, Michael ;
Sandler, Martin ;
Patton, Jim ;
Hutton, Brian ;
Sharir, Tali ;
Ben Haim, Shlomo ;
Ben Haim, Simona .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :635-643