Indoor air quality, thermal comfort and ventilation in deep energy retrofitted Irish dwellings

被引:32
作者
Coggins, Ann Marie [1 ,2 ]
Wemken, Nina [1 ,2 ]
Mishra, Asit Kumar [3 ,4 ]
Sharkey, Martin [1 ,2 ]
Horgan, Liam [1 ,2 ]
Cowie, Hilary [5 ]
Bourdin, Emmanuel [6 ]
McIntyre, Brian [7 ]
机构
[1] Natl Univ Ireland, Sch Nat Sci, Galway H91 TK33, Ireland
[2] Natl Univ Ireland, Ryan Inst, Galway H91 TK33, Ireland
[3] Natl Univ Ireland, MaREI Ctr, Ryan Inst, Galway H91 TK33, Ireland
[4] Natl Univ Ireland, Sch Engn, Galway H91 TK33, Ireland
[5] IOM, Edinburgh EH14 4AP, Midlothian, Scotland
[6] Local Govt & Heritage, Dept Housing, Climate Act Policy & Construct Ind Regulat Unit, Custom House,D01 W6X0, Dublin 1, Ireland
[7] Sustainable Energy Author Ireland, 3 Pk Pl,Hatch St Upper,D02 FX65, Dublin 2, Ireland
关键词
Deep energy retrofit; Indoor air quality; Energy efficient homes; Formaldehyde; PM2.5; SOLID-FUEL; RATES; BUILDINGS; HEALTH;
D O I
10.1016/j.buildenv.2022.109236
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Residential building stock energy retrofits will play a key role in EU climate actions. The impact of these retrofits on indoor air quality (IAQ) and occupant comfort needs to be assessed to inform future renovation programmes. This study evaluated IAQ and occupant satisfaction in a sample (n = 14) of deep energy retrofitted Irish residences, at least 12 months post retrofit. Measurements of PM2.5, formaldehyde, total volatile organic compounds (TVOCs), carbon monoxide, radon, and carbon dioxide were made in the main bedroom and living area over a period of two days to three months (depending on the pollutant). Temperature and humidity in most homes were within design comfort limits. Higher concentrations of all pollutants were measured in bedrooms. Only 30% of bedroom data met EN16798 Category I limits for CO2 (within 380 ppm of outdoor concentrations), suggesting that bedrooms maybe under ventilated. Median formaldehyde concentrations of 25.4 and 20.7 mu g/m(3) were detected in bedroom and living rooms respectively, with building materials likely being the major source. All radon data (apart from one home located in a high radon area) was less than the national reference value of 200 Bq/m(3). Measured ventilation extract flow rates in most participating homes would not meet the minimum performance requirements in Irish Regulations of 2019 - introduced post completion of the retrofits in this study. Greater compliance with the ventilation requirements of retrofits and the promotion and use of low emitting construction materials are recommended.
引用
收藏
页数:12
相关论文
共 69 条
[1]   A methodology for the selection of pollutants for ensuring good indoor air quality using the de-trended cross-correlation function [J].
Alonso, Maria Justo ;
Wolf, Sebastian ;
Jorgensen, Rikke Bramming ;
Madsen, Henrik ;
Mathisen, Hans Martin .
BUILDING AND ENVIRONMENT, 2022, 209
[2]  
[Anonymous], PROJECT MANAGEMENT C
[3]  
[Anonymous], Energy performance of buildings directive
[4]  
[Anonymous], 2005, AGENCY TOXIC SUBSTAN
[5]  
[Anonymous], 2007, 152512007 INDOOR ENV
[6]  
[Anonymous], About us
[7]  
[Anonymous], 2012, CIT GUID RAD GUID PR
[8]  
[Anonymous], Sustainable Energy Authority of Ireland (SEAI)
[9]  
[Anonymous], US EPA NATL AMBIENT
[10]  
[Anonymous], MET EIREANN HIST DAT