Recovery of Bacteria in Filtering Facepiece Respirators and Effects of Artificial Saliva/Perspiration on Bacterial Survival and Performance of Respirators

被引:16
|
作者
Lin, Tzu-Hsien [1 ]
Tang, Feng-Cheng [2 ]
Chiang, Chia-Hsiu [3 ]
Chang, Cheng-Ping [4 ,5 ]
Lai, Chane-Yu [3 ,6 ]
机构
[1] China Med Univ, Dept Dent Hyg, Taichung, Taiwan
[2] Changhua Christian Hosp, Dept Occupat Med, Changhua, Taiwan
[3] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[4] Minist Labor, Inst Occupat Safety & Hlth, New Taipei, Taiwan
[5] Chang Jung Christian Univ, Dept Occupat Safety & Hlth, Tainan, Taiwan
[6] Chung Shan Med Univ Hosp, Dept Occupat Med, Taichung, Taiwan
关键词
Respirator; Bioaerosols; Filtration; Personnel protection; Respiratory health; SURGICAL MASK; AEROSOLS; MICROORGANISMS; HUMIDITY; STORAGE; IMPACT; FLOW;
D O I
10.4209/aaqr.2015.03.0196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study seeks the optimal method for recovering loaded bacteria from filtering facepiece respirators (FFRs) and investigates the effects of artificial saliva (AS), artificial perspiration (AP) and storage conditions on the survival of bioaerosols and the filter performance of FFRs. Bioaerosols were generated using a Collison nebulizer in a test system and loaded on either N95 or surgical masks. Elution using centrifuge at 3500 rpm for ten min followed by vortexing for one min yielded a high relative survival (RS) rate of airborne Bacillus subtilis (BS) spores. When AS was added to the N95 FFR, the RS of BS declined during the first eight hours of storage and then increased to reach its highest value after 24 hr of storage. The worst case with the highest RS was at 37 degrees C and 95% RH (p < 0.001). When AP was added to the N95 FFR and stored under the worst conditions, RS increased by over 100% during eight hours of storage. When AS was added to a surgical mask, the RS also increased by over 100% in eight hours of storage, but when AP was added to the surgical mask, RS immediately declined. When Escherichia coli (EC) were tested, their RS was lower than those of the BS samples. (Following loading with bacteria, the particle penetration and filter quality factor (q(f)) increased (p < 0.001) but the slope of the linear regression between the pressure drop (Delta p) and the flow rate through the filter was not statistically significantly changed (p = 0.233). In conclusion, AS and AP increased the survival of BS; AP was especially effective in N95 masks and AS was especially effective in surgical masks.
引用
收藏
页码:187 / 197
页数:11
相关论文
共 18 条
  • [1] Performance Comparison of N95 and P100 Filtering Facepiece Respirators with Presence of Artificial Leakage
    Zhu, Jintuo
    He, Xinjian
    Guffey, Steve
    Wang, Liang
    Wang, Haifeng
    Cheng, Jianwei
    ANNALS OF WORK EXPOSURES AND HEALTH, 2020, 64 (02) : 202 - 216
  • [2] Performance evaluation of filtering facepiece respirators using virus aerosols
    Zuo, Zhili
    Kuehn, Thomas H.
    Pui, David Y. H.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (01) : 80 - 82
  • [3] Health effects of filtering facepiece respirators: Systematic review of pulmonary and cardiovascular effects
    Harber, Philip
    Beckett, William S.
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2023, 66 (03) : 181 - 198
  • [4] Physiological effects of filtering facepiece respirators based on age and exercise intensity
    Go, Sulbee
    Yang, Yeram
    Park, Suhong
    Moon, Hyo Youl
    Yoon, Chungsik
    PLOS ONE, 2024, 19 (08):
  • [5] Evaluation of Regeneration Processes for Filtering Facepiece Respirators in Terms of the Bacteria Inactivation Efficiency and Influences on Filtration Performance
    He, Weidong
    Guo, Yinghe
    Gao, Hanchao
    Liu, Jingxian
    Yue, Yang
    Wang, Jing
    ACS NANO, 2020, 14 (10) : 13161 - 13171
  • [6] Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols
    Lore, Michael B.
    Sebastian, John M.
    Brown, TeAnne L.
    Viner, Andrew S.
    McCullough, Nicole V.
    Hinrichs, Steven H.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (02) : 69 - 80
  • [7] Evaluation of filtration characteristics and microbial recovery rates of commercial filtering facepiece respirators against airborne bacterial particles
    Bin Jeong, Sang
    Ko, Hyun Sik
    Seo, Sung Chul
    Jung, Jae Hee
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 682 : 729 - 736
  • [8] Health effects of filtering facepiece respirators: Research and clinical implications of comfort, thermal, skin, psychologic, and workplace effects
    Harber, Philip
    Beckett, William S.
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2023, 66 (12) : 1017 - 1032
  • [9] Relative survival of Bacillus subtilis spores loaded on filtering facepiece respirators after five decontamination methods
    Lin, T. -H.
    Tang, F. -C.
    Hung, P. -C.
    Hua, Z. -C.
    Lai, C. -Y.
    INDOOR AIR, 2018, 28 (05) : 754 - 762
  • [10] Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators
    Rengasamy, Samy
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2009, 53 (02) : 117 - 128