Comparing the visualization of microcalcifications with direct magnification in digital full-field mammography vs. film-screen mammography

被引:17
作者
Diekmann, F
Diekmann, S
Bick, U
Rogalla, P
Blohmer, JU
Winzer, KJ
Hamm, B
机构
[1] Univ Klinikum Berlin, Charite, Inst Radiol, D-10117 Berlin, Germany
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[3] Univ Klinikum Berlin, Charite, Klin Gynakol & Geburtshilfe, D-10117 Berlin, Germany
[4] Univ Klinikum Berlin, Charite, Chirurg Klin & Poliklin, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 03期
关键词
mammography; magnification; microcalcifications; energy subtraction; wavelet;
D O I
10.1055/s-2002-20603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the conspicuity of microcalcifications in magnified mammographic views of preparations obtained with full field digital mammography (FFDM), film-screen mammography (FSM), and the DIMA technique. Material and Methods: Twelve preparations were examined by FFDM and FSM using 1.8 x magnification and DIMA using 7 x magnification. Parameter settings were identical for all three techniques. The number of visible microcalcifications was then determined for each modality by three radiologists. As far as possible, all preparations were X-rayed at 22 kV and 10 mAS. Results: Altogether 9705 calcifications were counted (DIMA: 1609/1542/1534; FFDM: 1020/753/881; FSM: 901/643/822). The total number of microcalcifications identified with the DIMA technique was 4685 as compared to 2654 with FFDM and 2366 with FSM. The calcifications counted with FFDM and FSM thus corresponded to 56.6 % and 50.5 %, respectively, of those identified with DIMA. The differences between the groups were statistically significant (F-Test, p < 0.05). Conclusion: Significantly more calcifications are identified when magnified mammographic views of preparations containing microcalcifications are obtained with the DIMA technique compared to FFDM or FSM. FFDM depicts markedly more calcifications than FSM. This means one should increase spatial resolution. Digital mammography offers the potential for improved visualization of microcalcifications with advanced applications.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 15 条
  • [1] Segmentation and numerical analysis of microcalcifications on mammograms using mathematical morphology
    Betal, D
    Roberts, N
    Whitehouse, GH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (837) : 903 - 917
  • [2] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [3] Diekmann F, 2001, Zentralbl Gynakol, V123, P117, DOI 10.1055/s-2001-12491
  • [4] Intraoperative digital radiography for diagnosis of non-palpable breast lesions
    Diekmann, F
    Grebe, S
    Bick, U
    Winzer, KJ
    Paepke, S
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 969 - 971
  • [5] Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography.
    Grunert, JH
    Borchert, B
    Farber, A
    Gmelin, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (04): : 302 - 306
  • [6] Grunert JH, 1999, ROFO-FORTSCHR RONTG, V170, P347
  • [7] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [8] Digital mammography in direct magnification technique using a large-area amorphous silicon X-ray detector.
    Hermann, KP
    Hundertmark, C
    Funke, M
    von Brenndorff, A
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 503 - 506
  • [9] Positive predictive value of the breast imaging reporting and data system
    Lacquement, MA
    Mitchell, D
    Hollingsworth, AB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 189 (01) : 34 - 40
  • [10] AN ANALYSIS OF 136 GROUPS OF MICRO-CALCIFICATION OF BENIGN ORIGIN - HOW SPECIFIC IS THE TRIANGLE PRINCIPLE
    LANYI, M
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1982, 136 (02): : 182 - 188