Characterisation of clinical and newly fabricated meshes for pelvic organ prolapse repair

被引:50
作者
Edwards, Sharon L. [1 ]
Werkmeister, Jerome A. [1 ]
Rosamilia, Anna [2 ]
Ramshaw, John A. M. [1 ]
White, Jacinta F. [1 ]
Gargett, Caroline E. [2 ,3 ]
机构
[1] CSIRO Mat Sci & Engn, Clayton, Vic 3168, Australia
[2] Monash Univ, Dept Obstet & Gynaecol, Clayton, Vic 3800, Australia
[3] Monash Inst Med Res, Ritchie Ctr, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
Burst strength; Flexural rigidity; Mesh; Multi-axial; Pelvic organ prolapsed; Tensile properties; BIOMECHANICAL PROPERTIES; GENITAL PROLAPSE; LIFETIME RISK; SURGERY; IMPACT;
D O I
10.1016/j.jmbbm.2013.04.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical meshes used in pelvic organ prolapse (POP) repair are predominantly manufactured from monofilament polypropylene (PP). Complications from the use of these meshes in transvaginal kits, including mesh exposure and pain, have prompted two public health notifications by the FDA. The aim of this study was to compare several clinical PP POP meshes to new fabricated POP meshes, knitted from alternative polymers, for their mechanical properties using standard and clinically relevant multi-axial testing methods. Five new meshes were warp knitted to different architectures and weights from polyamide and polyetheretherketone monofilaments. A composite mesh of a polyamide mesh incorporating a gelatin layer was also fabricated to enable the potential delivery of cells on these meshes. Meshes were assessed for their structural characteristics and mechanical properties, using uniaxial stiffness, permanent strain, bending rigidity and multi-axial burst strength methods. Results were compared to three clinical urogynaecological polypropylene meshes: Polyform (R), Gynemesh (TM) PS, and IntePro (R). New fabricated meshes were uniaxially less stiff (less than 0.24 N/mm and 1.20 N/mm in toe and linear regions, respectively) than the Gynemesh (0.48 N/mm and 2.08 N/mm in toe and linear regions, respectively) and IntePro (0.57 N/mm in toe region) clinical meshes, with the gelatin coated PA mesh exhibiting lower permanent strain than Polyform clinical mesh (8.1% vs. 23.5%). New meshes had lower burst stiffness than Polyforrn (less than 16.9 N/mm for new meshes and 26.6 N/mm for Polyform). Within the new mesh prototypes, the PA meshes, either uncoated (4.7-5.7 mu N m) or with gelatin coating (16.7 mu N m) possessed lower bending rigidity than both Polyform and Gynemesh (46.2 mu N m and 36.4 mu N m, respectively). The new fabricated mesh designs were of similar architecture, but with some improved mechanical properties, compared to clinical POP meshes. Multi-axial analysis of new and clinical mesh designs provides greater discriminatory power in analysing mesh mechanical properties for clinical applications. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 30 条
[1]   Mechanical properties of polypropylene mesh used in pelvic floor repair [J].
Afonso, J. S. ;
Martins, P. A. L. S. ;
Girao, M. J. B. C. ;
Jorge, R. M. Natal ;
Ferreira, A. J. M. ;
Mascarenhas, T. ;
Fernandes, A. A. ;
Bernardes, J. ;
Baracat, E. C. ;
de Lima, G. Rodrigues ;
Patricio, B. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (03) :375-380
[2]   An analysis of the bending rigidity of warp-knitted fabrics: a comparison of experimental results to a mechanical model [J].
Ajeli, S. ;
Jeddi, Ali. A. A. ;
Rastgo, A. ;
Gorga, R. E. .
JOURNAL OF THE TEXTILE INSTITUTE, 2009, 100 (06) :496-506
[3]   Anterior Colporrhaphy versus Transvaginal Mesh for Pelvic-Organ Prolapse [J].
Altman, Daniel ;
Vayrynen, Tapio ;
Engh, Marie Ellstrom ;
Axelsen, Susanne ;
Falconer, Christian .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (19) :1826-1836
[4]  
Amid PK., 1997, HERNIA, V1, P15, DOI DOI 10.1007/BF02426382
[5]  
Campo E. A., 2008, SELECTION POLYM MAT
[6]  
Cook J G., 1993, Handbook of Textile Fibres, V5
[7]   The biology behind fascial defects and the use of implants in pelvic organ prolapse repair [J].
Deprest, Jan ;
Zheng, Fang ;
Konstantinovic, Maja ;
Spelzini, Federico ;
Claerhout, Filip ;
Steensma, Anneke ;
Ozog, Yves ;
De Ridder, Dirk .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2006, 17 (Suppl 1) :S16-S25
[8]   Mechanical properties of urogynecologic implant materials [J].
Dietz, HP ;
Vancaillie, P ;
Svehla, M ;
Walsh, W ;
Steensma, AB ;
Vancaillie, TG .
INTERNATIONAL UROGYNECOLOGY JOURNAL AND PELVIC FLOOR DYSFUNCTION, 2003, 14 (04) :239-243
[9]   Mechanical evaluation and cell response of woven polyetheretherketone scaffolds [J].
Edwards, S. L. ;
Werkmeister, J. A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (12) :3326-3331
[10]  
FDA Centre for Devices and Radiological Health, 2012, UR SURG MESH UPD SAF