Nonfocal Renal Biopsies: Adequacy and Factors Affecting a Successful Outcome

被引:5
作者
Goldstein, Mark A. [1 ,2 ]
Atri, Mostafa [2 ]
O'Malley, Martin [2 ]
Jacks, Lindsay [2 ]
John, Rohan [2 ]
Herzenberg, Andrew [2 ]
Reich, Heather [3 ]
Ghai, Sangeet [2 ]
机构
[1] John Radcliffe Hosp, Dept Radiol, Oxford OX3 9DU, England
[2] Toronto Gen Hosp, Joint Dept Med Imaging, Toronto, ON M5G 2C4, Canada
[3] Toronto Gen Hosp, Toronto, ON M5G 2C4, Canada
关键词
nonfocal; renal biopsy; adequacy; success rate; outcome; TRANSPLANT BIOPSY; NEEDLE-BIOPSY; SAFETY; GUN; CLASSIFICATION; ALLOGRAFTS; EFFICACY; DEVICES; KIDNEY; YIELD;
D O I
10.1097/RCT.0b013e31827bf6a0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. Methods: This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Results: Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. Conclusions: The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 22 条
  • [1] ALWALL N, 1952, ACTA MED SCAND, V143, P430
  • [2] NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES
    BOGAN, ML
    KOPECKY, KK
    KRAFT, JL
    HOLLADAY, AO
    FILO, RS
    LEAPMAN, SB
    THOMALLA, JV
    [J]. RADIOLOGY, 1990, 174 (01) : 273 - 275
  • [3] TECHNIQUE OF RENAL BIOPSY BY ULTRASOUND GUIDED PERCUTANEOUS PUNCTURE WITH A SPRING LOADED GUN
    BONDESTAM, S
    KONTKANEN, T
    TAAVITSAINEN, M
    TIULA, E
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1992, 26 (03): : 265 - 267
  • [4] Brown PAJ, 2000, CONS M KIDN BIOPS HA
  • [5] The Oxford classification of IgA nephropathy: rationale, clinicopathological correlations, and classification
    Cattran, Daniel C.
    Coppo, Rosanna
    Cook, H. Terence
    Feehally, John
    Roberts, Ian S. D.
    Troyanov, Stephan
    Alpers, Charles E.
    Amore, Alessandro
    Barratt, Jonathan
    Berthoux, Francois
    Bonsib, Stephen
    Bruijn, Jan A.
    D'Agati, Vivette
    D'Amico, Giuseppe
    Emancipator, Steven
    Emma, Francesco
    Ferrario, Franco
    Fervenza, Fernando C.
    Florquin, Sandrine
    Fogo, Agnes
    Geddes, Colin C.
    Groene, Hermann-Josef
    Haas, Mark
    Herzenberg, Andrew M.
    Hill, Prue A.
    Hogg, Ronald J.
    Hsu, Stephen I.
    Jennette, J. Charles
    Joh, Kensuke
    Julian, Bruce A.
    Kawamura, Tetsuya
    Lai, Fernand M.
    Leung, Chi Bon
    Li, Lei-Shi
    Li, Philip K. T.
    Liu, Zhi-Hong
    Mackinnon, Bruce
    Mezzano, Sergio
    Schena, F. Paolo
    Tomino, Yasuhiko
    Walker, Patrick D.
    Wang, Haiyan
    Weening, Jan J.
    Yoshikawa, Nori
    Zhang, Hong
    [J]. KIDNEY INTERNATIONAL, 2009, 76 (05) : 534 - 545
  • [6] Percutaneous US-guided Renal Biopsy: A Retrospective Study Comparing the 16-gauge End-cut and 14-gauge Side-notch Needles
    Constantin, Andre
    Brisson, Marie-Laure
    Kwan, Janet
    Proulx, Francesca
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (03) : 357 - 361
  • [7] Protocol biopsy of the stable renal transplant:: A multicenter study of methods and complication rates
    Furness, PN
    Philpott, CM
    Chorbadjian, MT
    Nicholson, ML
    Bosmans, JL
    Corthouts, BL
    Bogers, JJPM
    Schwarz, A
    Gwinner, W
    Haller, H
    Mengel, M
    Seron, D
    Moreso, F
    Cañas, C
    [J]. TRANSPLANTATION, 2003, 76 (06) : 969 - 973
  • [8] ULTRASONIC LOCALIZATION FOR RENAL BIOPSY
    GOLDBERG, BB
    POLLACK, HM
    KELLERMAN, E
    [J]. RADIOLOGY, 1975, 115 (01) : 167 - 170
  • [9] Safety of ultrasound-guided percutaneous renal biopsy - retrospective analysis of 1090 consecutive cases
    Hergesell, O
    Felten, H
    Andrassy, K
    Kuhn, K
    Ritz, E
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (04) : 975 - 977
  • [10] AUTOMATED BIOPSY DEVICES - A BLINDED EVALUATION
    HOPPER, KD
    ABENDROTH, CS
    STURTZ, KW
    MATTHEWS, YL
    STEVENS, LA
    SHIRK, SJ
    [J]. RADIOLOGY, 1993, 187 (03) : 653 - 660