Evaluation of the COVID-19 IgG/IgM Rapid Test from Orient Gene Biotech

被引:35
作者
Delliere, Sarah [1 ]
Salmona, Maud [2 ,3 ]
Minier, Marine [2 ]
Gabassi, Audrey [2 ]
Alanio, Alexandre [1 ]
Le Goff, Jerome [2 ,3 ]
Delaugerre, Constance [2 ,4 ]
Chaix, Marie-Laure [2 ,4 ]
机构
[1] Univ Paris, Serv Parasitol Mycol, Dept Agents Infect, Hop St Louis, Paris, France
[2] Univ Paris, Dept Agents Infect, Serv Virol, Hop St Louis, Paris, France
[3] Univ Paris, UMR 976, INSERM, Paris, France
[4] Univ Paris, UMR 944, INSERM, Paris, France
关键词
COVID-19; lateral flow assay; rapid test;
D O I
10.1128/JCM.01233-20
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
While the coronavirus disease 2019 (COVID-19) pandemic has peaked in many countries already, the current challenge is to assess population immunity on a large scale. Many serological tests are available and require urgent independent validation. Here, we report performance characteristics of Orient Gene Biotech COVID-19 IgG/IgM Rapid Test Cassette (OG) and compare it to Abbott SARS-CoV-2 IgG immunoassay (ASIA). Patients (n = 102) with a positive severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcriptase PCR (RT-PCR) were tested. The patients were asymptomatic (n = 2) or had mild (n = 37) or severe symptoms requiring hospitalization in a medical unit (n = 35) or intensive care unit (n = 28). Specificity was evaluated for 42 patients with previous viral and parasitic diseases as well as a high level of rheumatic factor. The sensitivity of OG was 95.8% (95% confidence interval (CI95%], 89.6 to 98.8) for samples collected >= 10 days after the onset of symptoms, which was equivalent to the sensitivity of ASIA of 90.5% (CI95%, 82.8 to 95.6). OG uncovered six false-negative results of ASIA, of which two had only IgM with OG. Specificity was 100% (CI95%, 93.4 to 100) with both tests on samples, including patients infected with endemic coronavirus. Overall, OG performance characteristics indicate that the test is suitable for routine use in clinical laboratories, and its performance is equivalent to that of immunoassay. Testing OG on a larger asymptomatic population may be needed to confirm these results.
引用
收藏
页数:5
相关论文
共 6 条
[1]   Performance Characteristics of the Abbott Architect SARS-CoV-2 IgG Assay and Seroprevalence in Boise, Idaho [J].
Bryan, Andrew ;
Pepper, Gregory ;
Wener, Mark H. ;
Fink, Susan L. ;
Morishima, Chihiro ;
Chaudhary, Anu ;
Jerome, Keith R. ;
Mathias, Patrick C. ;
Greninger, Alexander L. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (08)
[2]  
Li ZT, 2020, J MED VIROL, V92, P1518, DOI [10.1002/jmv.25727, 10.12052/gdutxb.200076]
[3]  
Pallett S, 2020, POINT CARE SEROLOGIC, DOI [10.21203/rs.3.rs-28006/v1, DOI 10.21203/RS.3.RS-28006/V1]
[4]  
Petherick A, 2020, LANCET, V395, P1101, DOI 10.1016/S0140-6736(20)30788-1
[5]   Laboratory Diagnosis of COVID-19: Current Issues and Challenges [J].
Tang, Yi-Wei ;
Schmitz, Jonathan E. ;
Persing, David H. ;
Stratton, Charles W. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (06)
[6]   Breadth of concomitant immune responses prior to patient recovery: a case report of non-severe COVID-19 [J].
Thevarajan, Irani ;
Nguyen, Thi H. O. ;
Koutsakos, Marios ;
Druce, Julian ;
Caly, Leon ;
van de Sandt, Carolien E. ;
Jia, Xiaoxiao ;
Nicholson, Suellen ;
Catton, Mike ;
Cowie, Benjamin ;
Tong, Steven Y. C. ;
Lewin, Sharon R. ;
Kedzierska, Katherine .
NATURE MEDICINE, 2020, 26 (04) :453-+