Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching

被引:890
作者
Clauser, KR
Baker, P
Burlingame, AL [1 ]
机构
[1] Univ Calif San Francisco, Dept Pharmaceut Chem, San Francisco, CA 94143 USA
[2] UCL, Ludwig Inst Canc Res, London, England
[3] UCL, Dept Biochem, London, England
关键词
D O I
10.1021/ac9810516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the impact of advances in mass measurement accuracy, +/-10 ppm (internally calibrated), on protein identification experiments. This capability was brought about by delayed extraction techniques used in conjunction with matrix-assisted laser desorption ionization (MALDI) on a reflectron time-of-flight (TOF) mass spectrometer. This work explores the advantage of using accurate mass measurement (and thus constraint on the possible elemental composition of components in a protein digest) in strategies for searching protein, gene, and EST databases that employ (a) mass values alone, (b) fragment-ion tagging derived from MS/MS spectra, and (c) de novo interpretation of MS/MS spectra. Significant improvement in the discriminating power of database searches has been found using only molecular weight values (i.e., measured mass) of >10 peptide masses. When MALDI-TOF instruments are able to achieve the +/-0.5-5 ppm mass accuracy necessary to distinguish peptide elemental compositions, it is possible to match homologous proteins having >70% sequence identity to the protein being analyzed. The combination of a +/-10 ppm measured parent mass of a single tryptic peptide and the near-complete amino acid (AA) composition information from immonium ions generated by MS/MS is capable of tagging a peptide in a database because only a few sequence permutations >11 AA's in length for an AA composition can ever be found in a proteome, Dc novo interpretation of peptide MS/MS spectra may be accomplished by altering our MS-Tag program to replace an entire database with calculation of only the sequence permutations possible from the accurate parent mass and immonium ion limited AA compositions. A hybrid strategy is employed using de novo MS/MS interpretation followed by text-based sequence similarity searching of a database.
引用
收藏
页码:2871 / 2882
页数:12
相关论文
共 71 条
  • [1] The cell as a collection of protein machines: Preparing the next generation of molecular biologists
    Alberts, B
    [J]. CELL, 1998, 92 (03) : 291 - 294
  • [2] BASIC LOCAL ALIGNMENT SEARCH TOOL
    ALTSCHUL, SF
    GISH, W
    MILLER, W
    MYERS, EW
    LIPMAN, DJ
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 1990, 215 (03) : 403 - 410
  • [3] [Anonymous], UNPUB
  • [4] FAST ALGORITHM FOR PEPTIDE SEQUENCING BY MASS-SPECTROSCOPY
    BARTELS, C
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (06): : 363 - 368
  • [5] TANDEM MASS-SPECTROMETRY OF PEPTIDES USING HYBRID AND 4-SECTOR INSTRUMENTS - A COMPARATIVE-STUDY
    BEAN, MF
    CARR, SA
    THORNE, GC
    REILLY, MH
    GASKELL, SJ
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (14) : 1473 - 1481
  • [6] VELOCITY DISTRIBUTIONS OF INTACT HIGH MASS POLYPEPTIDE MOLECULE IONS PRODUCED BY MATRIX ASSISTED LASER DESORPTION
    BEAVIS, RC
    CHAIT, BT
    [J]. CHEMICAL PHYSICS LETTERS, 1991, 181 (05) : 479 - 484
  • [7] QUALITATIVE ANALYSIS OF ORGANIC COMPOUNDS BY MASS SPECTROMETRY
    BEYNON, JH
    [J]. NATURE, 1954, 174 (4433) : 735 - 737
  • [8] UTILITY OF EXACT MASS MEASUREMENTS
    BIEMANN, K
    [J]. METHODS IN ENZYMOLOGY, 1990, 193 : 295 - 305
  • [9] SUBUNITS OF THE SACCHAROMYCES-CEREVISIAE SIGNAL RECOGNITION PARTICLE REQUIRED FOR ITS FUNCTIONAL EXPRESSION
    BROWN, JD
    HANN, BC
    MEDZIHRADSZKY, KF
    NIWA, M
    BURLINGAME, AL
    WALTER, P
    [J]. EMBO JOURNAL, 1994, 13 (18) : 4390 - 4400
  • [10] BROWN RS, 1995, J ANAL CHEM+, V67, P1998