Catheter obstruction effect on pulsatile flow rate-pressure drop during coronary angioplasty

被引:20
作者
Banerjee, RK [1 ]
Back, LH
Back, MR
Cho, YI
机构
[1] Fluent Inc, Lebanon, NH 03766 USA
[2] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
[3] Univ S Florida, Coll Med, Div Vasc Surg, Tampa, FL 33606 USA
[4] Drexel Univ, Dept Mech Engn & Mech, Philadelphia, PA 19104 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1999年 / 121卷 / 03期
关键词
D O I
10.1115/1.2798321
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The coupling of computational hemodynamics to measured translesional mean pressure gradients with an angioplasty catheter in human coronary stenoses was evaluated. A narrowed flow cross section with the catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angioplasty; thus elevating the pressure gradient and reducing blood pow during the measurements. For resting conditions with the catheter present, flow was believed to be about 40 percent of normal basal flow in the absence of the catheter, and for hyperemia, about 20 percent of elevated flow in the patient group. The computations indicated that the velocity field was viscous dominated and quasi-steady with negligible phase lag in the Delta p(t) - (u) over bar(t) relation during the cardiac cycle at the lower hydraulic Reynolds numbers and frequency parameter. Hemodynamic interactions with smaller catheter-based pressure sensors evolving in clinical use require subsequent study since artifactually elevated translesional pressure gradients can occur during measurements with current angioplasty catheters.
引用
收藏
页码:281 / 289
页数:9
相关论文
共 28 条
[1]   MEASUREMENT OF TRANSSTENOTIC PRESSURE-GRADIENT DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ANDERSON, HV ;
ROUBIN, GS ;
LEIMGRUBER, PP ;
COX, WR ;
DOUGLAS, JS ;
KING, SB ;
GRUENTZIG, AR .
CIRCULATION, 1986, 73 (06) :1223-1230
[2]  
Back L.H, 1992, ADV BIOENG, V22, P337
[3]   ESTIMATED MEAN FLOW RESISTANCE INCREASE DURING CORONARY-ARTERY CATHETERIZATION [J].
BACK, LH .
JOURNAL OF BIOMECHANICS, 1994, 27 (02) :169-175
[4]   Flow rate pressure drop relation in coronary angioplasty: Catheter obstruction effect [J].
Back, LH ;
Kwack, EY ;
Back, MR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01) :83-89
[5]   Hemodynamic consequences of stenosis remodeling during coronary angioplasty [J].
Back, MR ;
White, RA ;
Kwack, EY ;
Back, LH .
ANGIOLOGY, 1997, 48 (02) :99-109
[6]  
BAKER AJ, 1983, FINITE ELEMENT COMPU, P153
[7]  
Banerjee RK, 1997, INT J COMPUT FLUID D, V9, P23
[8]  
BANERJEE RK, 1992, THESIS DREXEL U PHIL
[9]   DYNAMIC MECHANISMS IN HUMAN CORONARY STENOSIS [J].
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1984, 70 (06) :917-922
[10]   EXPERIMENTAL-STUDY OF PULSATILE AND STEADY FLOW THROUGH A SMOOTH TUBE AND AN ATHEROSCLEROTIC CORONARY-ARTERY CASTING OF MAN [J].
CHO, YI ;
BACK, LH ;
CRAWFORD, DW ;
CUFFEL, RF .
JOURNAL OF BIOMECHANICS, 1983, 16 (11) :933-946