Comparison of Laboratory and Field Measurements of Backfill Hydraulic Conductivity for a Large-Scale Soil-Bentonite Cutoff Wall

被引:20
|
作者
Malusis, Michael A. [1 ]
Barlow, Landon C. [2 ]
机构
[1] Bucknell Univ, Dept Civil & Environm Engn, 1 Dent Dr, Lewisburg, PA 17837 USA
[2] Haley & Aldrich Inc, 100 Corp Pl, Rocky Hill, CT 06067 USA
基金
美国国家科学基金会;
关键词
Backfill; Bentonite; Cutoff wall; Hydraulic conductivity; Slug test; SLUG TEST;
D O I
10.1061/(ASCE)GT.1943-5606.0002311
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Soil-bentonite (SB) cutoff walls are commonly employed to control groundwater flow and contaminant migration, and the hydraulic conductivity (k) of the SB backfill is a critical parameter in these applications. In this study, an evaluation of backfillkwas conducted for a large-scale SB cutoff wall (approximately 200 m long and 7 m deep) constructed and instrumented for field research. Measurements of k(more than 150 in total) were obtained via (1) laboratory (flexible-wall and rigid-wall) tests on specimens molded from surface grab samples of the field-mixed backfill collected during construction, (2) laboratory (flexible-wall) tests on undisturbed backfill specimens prepared from Shelby tube samples taken from the wall, and (3) in situ (slug) tests conducted at 12 different locations within the wall. The laboratory tests were conducted in stages over a range of applied effective stresses (sigma '=6.9, 13.8, 20.7, and 34.5 kPa) that encompassed the range of mean in situ effective stresses measured in the backfill (6-12 kPa) via embedded earth pressure and pore pressure sensors. At a given sigma ', flexible-wallkvalues for the undisturbed specimens were similar to those for the laboratory molded specimens. However,k decreased with increasing sigma ' in all of the laboratory tests, as expected, and the differences betweenk values measured at the lower stresses (6.9-13.8 kPa) and those measured at the higher stresses (20.7-34.8 kPa) were statistically significant. The flexible-wall tests underestimated k relative to the slug tests, but the differences generally were small (on average, within a factor of 2) when considering only the flexible-wall specimens tested at the lower applied stresses (6.9-13.8 kPa) that more closely matched the in situ stresses. The results demonstrate the importance of conducting laboratory k tests on SB backfill at stresses representative of the in situ stresses, which are limited by frictional load transfer along the sidewalls and tend to be lower than expected based on an assumed geostatic stress distribution. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 34 条
  • [21] Compressibility and hydraulic conductivity of clayey soil mixed with calcium bentonite for slurry wall backfill: Initial assessment
    Fan, R. -D.
    Du, Y. J.
    Reddy, Krishna R.
    Liu, S. Y.
    Yang, Y. L.
    APPLIED CLAY SCIENCE, 2014, 101 : 119 - 127
  • [22] THE HYDRAULIC CONDUCTIVITY OF MODEL SOIL-BENTONITE CUT-OFF WALL BACKFILLS UNDER CALCIUM CHLORIDE SOLUTION
    Wang, R.
    Xu, H. Q.
    Zhou, A. Z.
    Jiang, P. M.
    Liu, S. Q.
    Song, M. M.
    APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2019, 17 (04): : 9813 - 9826
  • [23] Scale effect on hydraulic conductivity and solute transport: Small and large-scale laboratory experiments and field experiments
    Godoy, Vanessa A.
    Zuquette, Lazaro Valentin
    Gomez-Hernandez, J. Jaime
    ENGINEERING GEOLOGY, 2018, 243 : 196 - 205
  • [24] Discussion of "measuring the hydraulic conductivity of soil-bentonite backfill" by Jeremy P. Britton, George M. Filz, and Wayne E. Herring
    Chapuis, Robert P.
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2006, 132 (06) : 809 - 812
  • [25] Closure to "measuring the hydraulic conductivity of soil-bentonite backfill" by Jeremy P. Britton, George M. Filz, and Wayne E. Herring
    Britton, Jeremy P.
    Filz, George M.
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2006, 132 (06) : 812 - 814
  • [26] Large-scale lateral saturated soil hydraulic conductivity as a metric for the connectivity of subsurface flow paths at hillslope scale
    Pirastru, Mario
    Iovino, Massimo
    Marrosu, Roberto
    Di Prima, Simone
    Giadrossich, Filippo
    Awada, Hassan
    HYDROLOGICAL PROCESSES, 2022, 36 (08)
  • [27] Large-Scale Hydraulic Performance Testing of a Geotextile Mechanically Stabilized Earth (MSE) Wall Constructed with Recycled Concrete Aggregate Backfill
    Mardani, Azin
    Abbaspour, Aiyoub
    Tanyu, Burak F.
    Siemens, Greg
    Bathurst, Richard J.
    Likos, William J.
    GEOTECHNICAL TESTING JOURNAL, 2024, 47 (01): : 215 - 234
  • [28] COMPARISON OF LABORATORY AND FIELD DETERMINED SATURATED HYDRAULIC CONDUCTIVITY AND PREDICTION FROM SOIL PARTICLE-SIZE
    GUMBS, FA
    TROPICAL AGRICULTURE, 1974, 51 (03): : 375 - 382
  • [29] Microbial occurrence in bentonite-based buffer, backfill and sealing materials from large-scale experiments at AECL's Underground Research Laboratory
    Stroes-Gascoyne, Simcha
    APPLIED CLAY SCIENCE, 2010, 47 (1-2) : 36 - 42
  • [30] Subsurface flow and large-scale lateral saturated soil hydraulic conductivity in a Mediterranean hillslope with contrasting land uses
    Pirastru, Mario
    Bagarello, Vincenzo
    Iovino, Massimo
    Marrosu, Roberto
    Castellini, Mirko
    Giadrossich, Filippo
    Niedda, Marcello
    JOURNAL OF HYDROLOGY AND HYDROMECHANICS, 2017, 65 (03) : 297 - 306