PBGA Package Finite Element Analysis Based on the Physical Geometry Modeling using X-ray Micro CT Digital Volume Reconstruction

被引:0
|
作者
Lall, Pradeep [1 ]
Wei, Junchao [1 ]
机构
[1] Auburn Univ, NSF CAVE3 Elect Res Ctr, Dept Mech Engn, Auburn, AL 36849 USA
来源
2016 15TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM) | 2016年
关键词
BGA Package; Finite Element Analysis; Thermal Mechanics; Geometry Modeling; X-ray CT; Reliability; Image Processing; UMAT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Ball-grid array BGA package can fail under thermo-mechanical loading such as thermal cycling. It is important to study the strain and stress of an electronic package using Finite Element Analysis (FEA) that is based on physical geometry and dimension. One can precisely view the real package dimension under the CT scan. Use of CT data for FE model creation will allow for greater ability to capture the actual structure. Currently, many people try to take geometrical measurements with calipers or micrometers, which only measures the surface and outline. CT has been widely used for medical imaging. Previous researchers have used medical CT-based femur model to find stress concentration in the femur under mechanical stress (Vulovic, Korunovic, & Trajanovic, 2011), and CT-Scan data to model the vertebra geometry and its properties in the FEA (D.Jovanovic & Lj. Jovanovic, 2010), creating FE models of the human feet (Antunes & Dias, 2008). In the electronic packaging field, it is worthwhile to create the finite element model based on a real geometry rather than assumed nominal dimensions. The ability to capture and port the actual geometry into the FE platform allows for studies which target the effect of manufacturing variabilities and dimensional variations on the reliability and performance of the semiconductor assembly. In this paper, a generalized scheme of FEA model creation using the X-ray micro CT has been put forward. Firstly, a procedure for micro CT scan and a technique for volume reconstruction have been developed. Secondly, the CT data structure has been demonstrated, and a FEA global and local model from the scan has been incorporated into the analysis. Thirdly, the Annand Visco-plasticity model of SAC-305 has been utilized and merged into the FEA software to model material behavior. In the end, a model of a void solder joint under thermal cycling has been presented. The cumulative plastic work and stress-strain hysteresis loop have been plotted.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 36 条
  • [21] Crystal Plasticity finite element analysis based on crystal orientation mapping with three-dimensional x-ray diffraction microscopy
    Setoyama, Daigo
    Hayashi, Yujiro
    Iwata, Noritoshi
    MECHANICAL STRESS EVALUATION BY NEUTRONS AND SYNCHROTRON RADIATION VII, 2014, 777 : 142 - 147
  • [22] Three-dimensional modeling of moisture transport in wood using near-infrared hyperspectral imaging and X-ray computed tomography in conjunction with finite element analysis
    Wenpeng Zeng
    Takaaki Fujimoto
    Tetsuya Inagaki
    Satoru Tsuchikawa
    Te Ma
    Journal of Wood Science, 70
  • [23] Three-dimensional modeling of moisture transport in wood using near-infrared hyperspectral imaging and X-ray computed tomography in conjunction with finite element analysis
    Zeng, Wenpeng
    Fujimoto, Takaaki
    Inagaki, Tetsuya
    Tsuchikawa, Satoru
    Ma, Te
    JOURNAL OF WOOD SCIENCE, 2024, 70 (01)
  • [24] Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis
    Shefelbine, SJ
    Simon, U
    Claes, L
    Gold, A
    Gabet, Y
    Bab, I
    Müller, R
    Augat, P
    BONE, 2005, 36 (03) : 480 - 488
  • [25] Determination of representative elementary volume of digital coal based on fractal theory with X-ray CT data and its application in fractal permeability predication model
    Fang, Huihuang
    Sang, Shuxun
    Liu, Shiqi
    Liu, Huihu
    Xu, Hongjie
    Huang, Yanhui
    FRONTIERS OF EARTH SCIENCE, 2022, 16 (03) : 657 - 670
  • [26] Determination of representative elementary volume of digital coal based on fractal theory with X-ray CT data and its application in fractal permeability predication model
    Huihuang Fang
    Shuxun Sang
    Shiqi Liu
    Huihu Liu
    Hongjie Xu
    Yanhui Huang
    Frontiers of Earth Science, 2022, 16 : 657 - 670
  • [27] Quantifying the effect of porosity on the evolution of deformation and damage in Sn-based solder joints by X-ray microtomography and microstructure-based finite element modeling
    Padilla, E.
    Jakkali, V.
    Jiang, L.
    Chawla, N.
    ACTA MATERIALIA, 2012, 60 (09) : 4017 - 4026
  • [28] SPARSE-VIEW X-RAY SPECTRAL CT RECONSTRUCTION USING ANNIHILATING FILTER-BASED LOW RANK HANKEL MATRIX APPROACH
    Han, Yo Seob
    Jin, Kyong Hwan
    Kim, Kyungsang
    Ye, Jong Chul
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 573 - 576
  • [29] Meso-damage analysis of concrete based on X-ray CT in-situ compression and using deep learning method
    Li, Na
    Zhao, Yanru
    Xing, Yongming
    He, Xiaoyan
    Li, Haixia
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 18
  • [30] A method for measuring single-crystal elastic moduli using high-energy X-ray diffraction and a crystal-based finite element model
    Efstathiou, C.
    Boyce, D. E.
    Park, J. -S.
    Lienert, U.
    Dawson, P. R.
    Miller, M. P.
    ACTA MATERIALIA, 2010, 58 (17) : 5806 - 5819